Araştırma Makalesi

Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol

Cilt: 1 Sayı: 3 29 Kasım 2025
PDF İndir
EN TR

Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol

Öz

In this study, the applicability of SYBR Safe gel stain in the Comet Assay protocol was evaluated, and staining conditions were optimized. The mutagenic and toxic properties of ethidium bromide (EtBr) have increased the need for alternative fluorescent dyes. In the study using human SH-SY5Y neuroblastoma cell line, DNA damage was induced by H₂O₂ and analyzed by fluorescence microscopy after staining with SYBR Safe. Different SYBR Safe concentrations (1:1000-1:10000) and staining times (2-30 min) were tested. The optimum signal to image ratio was obtained with a dilution of 1:2500 and an incubation time of 5 min. Furthermore, 0.1 M NaCl solution was found to be the most suitable carrier medium in terms of dye stability and fluorescence quality. It was observed that the prepared preparations were stable at +4°C for up to 1 month. These results show that SYBR Safe is not only a safe alternative but also provides high image quality and cost advantage with low concentration. The findings demonstrate that SYBR Safe is a safe, economical, and high-performance alternative to EtBr in comet assay applications.

Anahtar Kelimeler

Kaynakça

  1. 1. Lee PY, Costumbrado J, Hsu CY, Kim YH. Agarose gel electrophoresis for the separation of DNA fragments. J Vis Exp. 2012(62).
  2. 2. Nass MM. Differential effects of ethidium bromide on mitochondrial and nuclear DNA synthesis in vivo in cultured mammalian cells. Exp Cell Res. 1972;72(1):211-22.
  3. 3. Haugland RP. Handbook of fluorescent probes and research products: Molecular probes; 2002.
  4. 4. Cosa G, Focsaneanu KS, McLean JR, McNamee JP, Scaiano JC. Photophysical properties of fluorescent DNA-dyes bound to single- and double-stranded DNA in aqueous buffered solution. Photochem Photobiol. 2001;73(6):585-99.
  5. 5. Ohta T, Tokishita S-i, Yamagata H. Ethidium bromide and SYBR Green I enhance the genotoxicity of UV-irradiation and chemical mutagens in E. coli. Mutation Research/Genetic Toxicology and Environmental Mutagenesis. 2001;492(1-2):91-7.
  6. 6. Singh NP, McCoy MT, Tice RR, Schneider EL. A simple technique for quantitation of low levels of DNA damage in individual cells. Experimental cell research. 1988;175(1):184-91.
  7. 7. Kumaravel TS, Vilhar B, Faux SP, Jha AN. Comet Assay measurements: a perspective. Cell Biol Toxicol. 2009;25(1):53-64.
  8. 8. Gandhi VP, Kesari KK, Kumar A. The Identification of Ethidium Bromide-Degrading Bacteria from Laboratory Gel Electrophoresis Waste. BioTech (Basel). 2022;11(1).

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sitogenetik, Moleküler Genetik

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

27 Kasım 2025

Yayımlanma Tarihi

29 Kasım 2025

Gönderilme Tarihi

19 Temmuz 2025

Kabul Tarihi

28 Ekim 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 1 Sayı: 3

Kaynak Göster

APA
Hüsunet, M. T., Kenger, İ. H., & Bilgin, B. (2025). Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol. GİBTÜ Sağlık Ve Biyolojik Bilimler Dergisi, 1(3), 82-87. https://doi.org/10.65308/gjohbs.2025.012
AMA
1.Hüsunet MT, Kenger İH, Bilgin B. Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol. SABİB. 2025;1(3):82-87. doi:10.65308/gjohbs.2025.012
Chicago
Hüsunet, Mehmet Tahir, İbrahim Halil Kenger, ve Batuhan Bilgin. 2025. “Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol”. GİBTÜ Sağlık Ve Biyolojik Bilimler Dergisi 1 (3): 82-87. https://doi.org/10.65308/gjohbs.2025.012.
EndNote
Hüsunet MT, Kenger İH, Bilgin B (01 Kasım 2025) Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol. GİBTÜ Sağlık Ve Biyolojik Bilimler Dergisi 1 3 82–87.
IEEE
[1]M. T. Hüsunet, İ. H. Kenger, ve B. Bilgin, “Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol”, SABİB, c. 1, sy 3, ss. 82–87, Kas. 2025, doi: 10.65308/gjohbs.2025.012.
ISNAD
Hüsunet, Mehmet Tahir - Kenger, İbrahim Halil - Bilgin, Batuhan. “Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol”. GİBTÜ Sağlık Ve Biyolojik Bilimler Dergisi 1/3 (01 Kasım 2025): 82-87. https://doi.org/10.65308/gjohbs.2025.012.
JAMA
1.Hüsunet MT, Kenger İH, Bilgin B. Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol. SABİB. 2025;1:82–87.
MLA
Hüsunet, Mehmet Tahir, vd. “Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol”. GİBTÜ Sağlık Ve Biyolojik Bilimler Dergisi, c. 1, sy 3, Kasım 2025, ss. 82-87, doi:10.65308/gjohbs.2025.012.
Vancouver
1.Mehmet Tahir Hüsunet, İbrahim Halil Kenger, Batuhan Bilgin. Use of SYBR Safe Gel Stain (Hibrigen) in Comet Assay: Short-Term, Low-Cost Protocol. SABİB. 01 Kasım 2025;1(3):82-7. doi:10.65308/gjohbs.2025.012