Araştırma Makalesi

Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs

Cilt: 8 Sayı: 3 30 Eylül 2018
  • Nilüfer Bıcakcı *
PDF İndir
TR EN

Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs

Öz

Abstract

Gated myocardial perfusion SPECT (g-MPS) is an important method in the diagnosis of coronary artery disease (CAD). Left ventricular ejection fraction (LVEF), end-systolic volume (ESV) and end-diastolic volume (EDV) are required parameters for evaluation of cardiac performance. Our aim is to compare LVEF and volume values and to determine normal limits in patients with normal myocardial perfusion using two (4D-MSPECT ve SIEMENS ICON® QGS)computer software programs.

 

Patients and Methods

One hundred nine females were included study with the suspicion of CAD but their g-MPS was reported as normal between October 2004 and February 2007. Single day rest-stress g-MPS protocol was applied. Modified Bruce protocol was done for effort test with tredmill performance or dobutamine injection for pharmacological effort. Reconstruction was performed via Butterworth filtration without attenuation correction. LVEF, ESV and EDV were calculated.

 

Results

The mean rest (REF) and stress (SEF) ejection fraction values between 4DM and QGS algorithms had significant differeneces statistically (∆REF[4DM-QGS])=9.5;

∆SEF[4DM-QGS]=8.9; p<0.05). Wide Blandt Alman limits (BAL) were detected among the results (BAL:[4DM-REF]-[QGS-REF]=26.4-(-7.8), R=0,61 P<0,05; 4DM-SEF-QGS-SEF:27.7-(-10.1), R=0,54; P=0,000). Significant differences (p<0.05) were found beside the strong correlation coefficient values (r=0.81-0.93) in the volumes.

 

Conclusion

There were significant differences in the averages between the two g-MPS software program in LEVF and volume values so they should not be used in place of each other at the follow-up of patients. 

Anahtar Kelimeler

Kaynakça

  1. 1- Paul A, Hasegawa S, Yoshioka J, Yamaguchi H, TsujimuraE, Tokita N, et al. Left ventricular volume and ejectionfraction from quantitative gated SPECT: comparison with gated pool SPECT and contrast ventriculography. J Nucl Med 1999; 40(P): 178.
  2. 2- Atsma DE, Bavelaar-Croon CD, Germano G, Dibbets Schneider P, van Eck-Smit BL, Pauwels EK, van der Wall EE. Good correlation between gated single photon emission.
  3. 3- Yoshioka J, Hasegawa S, Yamaguchi H, Tokita N, Paul AK, Xiuli M. Left ventricular volume and ejection fraction calculated from quantitative electrographic gated 99m technetium tetrofosmin myocardial SPECT. J Nucl Med1999; 40: 1693-1698.
  4. 4- Chua T, Kiat H, Germano G, Maurer G, van Train K, Friedman J, Berman D. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion,postexercise regional ventricular function and myocardial viability: correlation with echocardiography and rest thallium-201 scintigraphy. J Am Coll Cardiol 1994; 23:1107-1114.
  5. 5- Nichols K, Lefkowitz D, Faber T, Folks R, Cooke D, Garcia EV, et al. Echocardiographic validation of gated SPECT ventricular function measurements. J Nucl Med 2000; 41:1308-1314.
  6. 6- Bavelaar-Croon CD, Kayser HW, van der Wall EE, de Roos A, Dibbets-Schneider P, Pauwels EK, et al. Left ventricular function: correlation of quantitative gated SPECT and MR imaging over a wide range of values. Radiology 2000; 217: 572-575.
  7. 7- Tadamura E, Kudoh T, Motooka M, Inubushi M, Shirakawa S, Hattori N, et al. Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with threedimensional magnetic resonance imaging. J Am Coll Cardiol 1999; 33: 991-997.
  8. 8-Wright GA, McDade M, Keeble W, Martin W, Hutton I.Quantitative gated SPECT myocardial perfusion imaging with 201Tl: An assessment of the limitations. Nucl MedCommun 2000; 21: 1147-1151.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Nilüfer Bıcakcı * Bu kişi benim
Türkiye

Yayımlanma Tarihi

30 Eylül 2018

Gönderilme Tarihi

21 Haziran 2018

Kabul Tarihi

6 Eylül 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 8 Sayı: 3

Kaynak Göster

APA
Bıcakcı, N. (2018). Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs. Çağdaş Tıp Dergisi, 8(3), 239-244. https://doi.org/10.16899/gopctd.435461
AMA
1.Bıcakcı N. Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs. J Contemp Med. 2018;8(3):239-244. doi:10.16899/gopctd.435461
Chicago
Bıcakcı, Nilüfer. 2018. “Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs”. Çağdaş Tıp Dergisi 8 (3): 239-44. https://doi.org/10.16899/gopctd.435461.
EndNote
Bıcakcı N (01 Eylül 2018) Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs. Çağdaş Tıp Dergisi 8 3 239–244.
IEEE
[1]N. Bıcakcı, “Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs”, J Contemp Med, c. 8, sy 3, ss. 239–244, Eyl. 2018, doi: 10.16899/gopctd.435461.
ISNAD
Bıcakcı, Nilüfer. “Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs”. Çağdaş Tıp Dergisi 8/3 (01 Eylül 2018): 239-244. https://doi.org/10.16899/gopctd.435461.
JAMA
1.Bıcakcı N. Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs. J Contemp Med. 2018;8:239–244.
MLA
Bıcakcı, Nilüfer. “Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs”. Çağdaş Tıp Dergisi, c. 8, sy 3, Eylül 2018, ss. 239-44, doi:10.16899/gopctd.435461.
Vancouver
1.Nilüfer Bıcakcı. Left ventricular ejection fraction, end-systolic and end-diastolic volume values in female with normal gated myocardial perfusion spect: the comparison with 4dm-spect and Siemens Icon®-Qgs. J Contemp Med. 01 Eylül 2018;8(3):239-44. doi:10.16899/gopctd.435461