EN
IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY
Öz
Objective: Quantitative parathyroid SPECT imaging is a technique used to assess Primary hyperparathyroidism that may have potential in the identification and differentiation of parathyroid lesions as well as the estimation of disease severity. Studying the effect of data acquisition parameters on the quantification error is important for maximizing the accuracy of this diagnostic technique. In this study we examine the effects of different data acquisition parameters, namely the type of collimator, scatter correction status and reconstruction iteration number on the quantification accuracy using computer simulation. Methods: The SIMIND Monte Carlo Simulation and CASToR iterative reconstruction program was used to simulate a commercially available SPECT camera (Siemens Symbia Intevo Gamma Camera) with a crystal size of 29.55cm and 128x128 matrix size. A digital cylindrical phantom filled with water was constructed. A 0.36 cm radius spherical adenoma filled with a uniform 1MBq radioactivity is placed within the phantom. Low-Energy High Resolution (LEHR) and Low Energy Ultra High Resolution (LEUHR) collimator models are tested. Along with the presence of Scatter correction and differing iteration numbers (x16, x32). An image FOV based calibration method was used to gather quantitative information and checked against the input radioactivity. Results: The presence of scatter correction caused a 15-20% relative improvement in quantification accuracy. The optimal number of iterations produced a 10% relative improvement. Overall, accuracies as good as 7% in estimated activity concentration could be observed. Conclusion: The optimization of parameters can provide a significant improvement in quantification accuracy.
Anahtar Kelimeler
Kaynakça
- 1. Anon. (2016). ‘EANM’16’. Pp. 1–734 in European journal of nuclear medicine and molecular imaging. Vol. 43.
- 2. Bahreyni Toossi, M. T., J. Pirayesh Islamian, M. Momennezhad, M. Ljungberg, and S. H. Naseri. (2010). ‘SIMIND Monte Carlo Simulation of a Single Photon Emission CT.’ Journal of Medical Physics 35(1):42–47. doi: 10.4103/0971-6203.55967.
- 3. Bailey, Dale L., and Kathy P. Willowson. (2013). ‘An Evidence-Based Review of Quantitative SPECT Imaging and Potential Clinical Applications’. Journal of Nuclear Medicine 54(1):83–89.
- 4. Bailey, Dale L., and Kathy P. Willowson. (2014). ‘Quantitative SPECT/CT: SPECT Joins PET as a Quantitative Imaging Modality’. European Journal of Nuclear Medicine and Molecular Imaging 41(SUPPL. 1). doi: 10.1007/s00259-013-2542-4.
- 5. Bilezikian, John P., Maria Luisa Brandi, Richard Eastell, Shonni J. Silverberg, Robert Udelsman, Claudio Marcocci, and John T. Potts. (2014). ‘Guidelines for the Management of Asymptomatic Primary Hyperparathyroidism: Summary Statement from the Fourth International Workshop’. Pp. 3561–69 in Journal of Clinical Endocrinology and Metabolism. Vol. 99. Endocrine Society. 6. Bindu, Ch Hima, and K. Satya Prasad. (2012). An Efficient Medical Image Segmentation Using Conventional OTSU Method. Vol. 38.
- 7. Bong, Jung Kyun, Hye Kyung Son, Jong Doo Lee, and Hee Joung Kim. (2005). ‘Improved Scatter Correction for SPECT Images: A Monte Carlo Study’. IEEE Transactions on Nuclear Science 52(5 I):1263–70. doi: 10.1109/TNS.2005.858202.
- 8. Carvalho, L. E., A. C. Sobieranski, and A. von Wangenheim. (2018). ‘3D Segmentation Algorithms for Computerized Tomographic Imaging: A Systematic Literature Review’. Journal of Digital Imaging 31(6):799–850.
- 9. Dandurand, Karel, Dalal S. Ali, and Aliya A. Khan. (2021). ‘Primary Hyperparathyroidism: A Narrative Review of Diagnosis and Medical Management’. Journal of Clinical Medicine 10(8).
Ayrıntılar
Birincil Dil
İngilizce
Konular
Bilgisayar Yazılımı
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
30 Aralık 2023
Gönderilme Tarihi
17 Temmuz 2023
Kabul Tarihi
24 Kasım 2023
Yayımlandığı Sayı
Yıl 2023 Cilt: 6 Sayı: 2
APA
Güveniş, A., & Aytaç, B. (2023). IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY. Natural and Applied Sciences Journal, 6(2), 9-23. https://doi.org/10.38061/idunas.1325839
AMA
1.Güveniş A, Aytaç B. IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY. IDU Natural and Applied Sciences Journal (IDUNAS). 2023;6(2):9-23. doi:10.38061/idunas.1325839
Chicago
Güveniş, Albert, ve Bahadır Aytaç. 2023. “IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY”. Natural and Applied Sciences Journal 6 (2): 9-23. https://doi.org/10.38061/idunas.1325839.
EndNote
Güveniş A, Aytaç B (01 Aralık 2023) IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY. Natural and Applied Sciences Journal 6 2 9–23.
IEEE
[1]A. Güveniş ve B. Aytaç, “IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY”, IDU Natural and Applied Sciences Journal (IDUNAS), c. 6, sy 2, ss. 9–23, Ara. 2023, doi: 10.38061/idunas.1325839.
ISNAD
Güveniş, Albert - Aytaç, Bahadır. “IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY”. Natural and Applied Sciences Journal 6/2 (01 Aralık 2023): 9-23. https://doi.org/10.38061/idunas.1325839.
JAMA
1.Güveniş A, Aytaç B. IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY. IDU Natural and Applied Sciences Journal (IDUNAS). 2023;6:9–23.
MLA
Güveniş, Albert, ve Bahadır Aytaç. “IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY”. Natural and Applied Sciences Journal, c. 6, sy 2, Aralık 2023, ss. 9-23, doi:10.38061/idunas.1325839.
Vancouver
1.Albert Güveniş, Bahadır Aytaç. IMPROVING THE QUANTIFICATION ACCURACY OF Tc-99m MIBI DUAL-PHASE PARATHYROID SPECT/CT: A MONTE CARLO SIMULATION STUDY. IDU Natural and Applied Sciences Journal (IDUNAS). 01 Aralık 2023;6(2):9-23. doi:10.38061/idunas.1325839