Araştırma Makalesi

RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS

Cilt: 3 Sayı: 2 25 Aralık 2020
PDF İndir
EN

RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS

Öz

RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS Compared to the other imaging modalities Magnetic Resonance Imaging (MRI) system has many advantages. There is a great demand to carry out interventional cardiovascular procedures under MRI scanner. However, the lack of visible markers and MRI compatible interventional instruments and devices, is the main problem for realizing clinical applications with MRI guidance. In order to provide widespread usage of MRI for endovascular operations, commercial catheters and guidewires must be manufactured by considering many performance criteria including visualization, miniaturization, flexibility and safety. In this study, an orientation independent simulation model was developed and validated to obtain a reliable method for evaluating the designed RF marker structures in a MRI environment. Utilized RF coil designs have similar size and properties with former constructed clinical grade MRI compatible RF markers in experimental works [1]. Finite Element Method (FEM) simulations were carried out for different RF coil designs to make the computational analysis of their electrical and magnetic characteristics by using COMSOL Multiphysics program. By delineating an approved simulation platform of a MRI environment, various different designs of RF marker prototypes can be compared between each other in many aspects, instead of realizing these models. Proposed simulation platform enables a convenient facility to determine various parameters of micro coils that have significant effects on visibility and safety performance of the candidate designs including signal to noise ratio (SNR) and Quality (Q) factor, RF induced heating and specific absorption rate (SAR).

Anahtar Kelimeler

Kaynakça

  1. REFERENCES
  2. 1. Baysoy, E., Yildirim, D., Ozsoy, C., Mutlu, S., Kocaturk, O. (2016). Thin fillm based semi-active resonant marker design for low profile interventional cardiovascular MRI devices. Magnetic Resonance Materials in Physics, Biology and Medicine, 30(1), 93-101. Doi:10.1007/s10334-016-0586-8).
  3. 2. Lederman, R.J. (2006). NIH Public Access, 112(19), 3009-3017.
  4. 3. Barkhausen, J., Kahn, T., Krombach, G.A., Kuhl, C.K., Lotz, J., Maintz, D., Ricke, J., Schönberg, S.O., Vogl, T.J. and Wacker, F.K. (2017). White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application. RoFo: Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 189(7), 611-623. Doi:10.1055/s-0043-110011.
  5. 4. Gurler, N. & Ider, Y.Z. (2015). Numerical methods and software tools for simulation, design, and resonant mode analysis of radio frequency birdcage coils used in MRI. Concepts Magn. Reson., 45, 13-32. Doi:10.1002/cmr.b.21279.
  6. 5. Tadesse, Y. (2015). The electromagnetic simulation of birdcage coils for MRI based on Finite element method. Master of degree thesis, Youngstown State University, Ohio, The United States of America.
  7. 6. Sonmez, M., Saikus, C.E., Bell, J.A., Franson, D.N., Halabi, M., Faranesh, A.Z., Ozturk, C., Lederman, R.J., Kocaturk, O. (2012). MRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safety. Journal of Cardiovascular Magnetic Resonance, 14, 38. Doi:10.1186/1532-429X-14-38.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

25 Aralık 2020

Gönderilme Tarihi

5 Haziran 2020

Kabul Tarihi

8 Temmuz 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 3 Sayı: 2

Kaynak Göster

APA
Baysoy, E. (2020). RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS. Natural and Applied Sciences Journal, 3(2), 34-48. https://doi.org/10.38061/idunas.748352
AMA
1.Baysoy E. RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS. IDU Natural and Applied Sciences Journal (IDUNAS). 2020;3(2):34-48. doi:10.38061/idunas.748352
Chicago
Baysoy, Engin. 2020. “RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS”. Natural and Applied Sciences Journal 3 (2): 34-48. https://doi.org/10.38061/idunas.748352.
EndNote
Baysoy E (01 Aralık 2020) RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS. Natural and Applied Sciences Journal 3 2 34–48.
IEEE
[1]E. Baysoy, “RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS”, IDU Natural and Applied Sciences Journal (IDUNAS), c. 3, sy 2, ss. 34–48, Ara. 2020, doi: 10.38061/idunas.748352.
ISNAD
Baysoy, Engin. “RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS”. Natural and Applied Sciences Journal 3/2 (01 Aralık 2020): 34-48. https://doi.org/10.38061/idunas.748352.
JAMA
1.Baysoy E. RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS. IDU Natural and Applied Sciences Journal (IDUNAS). 2020;3:34–48.
MLA
Baysoy, Engin. “RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS”. Natural and Applied Sciences Journal, c. 3, sy 2, Aralık 2020, ss. 34-48, doi:10.38061/idunas.748352.
Vancouver
1.Engin Baysoy. RF MARKER SIMULATION MODEL FOR INTERVENTIONAL MRI APPLICATIONS. IDU Natural and Applied Sciences Journal (IDUNAS). 01 Aralık 2020;3(2):34-48. doi:10.38061/idunas.748352