Araştırma Makalesi

An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans

Cilt: 2 Sayı: 1 1 Mayıs 2021
PDF İndir
EN

An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans

Öz

The fact that fans are used in a large variety and wide areas today requires them to have a certain performance and quality. The test set-up to be used to determine the performance values of the fans should also be prepared and verified in accordance with standards such as ISO, ANSI / AMCA. In this study, a test set-up was designed and established in accordance with the ANSI / AMCA 210-16 standard. In order to ensure the accuracy of this test set-up, the static pressure values for different flow rates of the AXI500-5-25 model axial fan produced in a fan manufacturer company in Konya were measured, and data were obtained. The static pressure-flow rate performance curve obtained from the tests was compared with the manufacturer's catalog data. As the most important result in comparison, it was seen that the experimental and the catalog data were quite compatible. The highest difference between experimental and catalog data was obtained at the points where the flow rate is minimum and maximum. However, this difference was determined to be around 5%. With the results obtained in the study, it was determined that the accuracy of the experimental set-up designed and set up according to ANSI/AMCA 210-16 standard was ensured and it was suitable to be used for testing.

Anahtar Kelimeler

Kaynakça

  1. Eck,B., Fans, Design and Operation of Centrifugal, Axial Flow And Cross Flow Fans, First Edition, Biddles Ltd., Great Britain,1972.
  2. Canbazoğlu,S., Fan Mühendisliği-1, First Edition, Aironn Fan Mühendisliği Teknik Yayın, Turkey, 2020.
  3. Çakmanus, İ., Endüstriyel Fanlar Tasarım, İmalat ve Enerji Verimliliği, First Edition, TTMD Teknik Yayın No:23, Turkey,2009.
  4. Elliot,N., and Nadel,S.,Realizing Energy Efficiency Opportunities in Industrial Fan and Pump Systems, Report Number A304,USA, 2003.
  5. Waide,P., and Brunner,C., Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems, Working Paper, International Energy Agency, France,2011.
  6. TEDAŞ, 2019 Yili Türkiye Elektrik Dağitimi Sektör Raporu, Turkey,2020.
  7. Bleier,F., Fan Handbook Selection, Application and Design, First Edition, McGraw Hill,USA,1997.
  8. Zhu, X., Lin, W., and Du, Z., 2004.Experimental and Numerical Investigation of the Flow Field in the Tip Region of an Axial Ventilation Fan. ASME. J. Fluids Engineering,127(2),299–307.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Uzay Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Mayıs 2021

Gönderilme Tarihi

30 Mart 2021

Kabul Tarihi

28 Nisan 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 2 Sayı: 1

Kaynak Göster

APA
Güven, T. B., Altun, A. H., & Doğan, S. (2021). An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics, 2(1), 9-13. https://izlik.org/JA35ZY33GT
AMA
1.Güven TB, Altun AH, Doğan S. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics. 2021;2(1):9-13. https://izlik.org/JA35ZY33GT
Chicago
Güven, Türker Burak, Aziz Hakan Altun, ve Sercan Doğan. 2021. “An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans”. International Journal of Aeronautics and Astronautics 2 (1): 9-13. https://izlik.org/JA35ZY33GT.
EndNote
Güven TB, Altun AH, Doğan S (01 Mayıs 2021) An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics 2 1 9–13.
IEEE
[1]T. B. Güven, A. H. Altun, ve S. Doğan, “An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans”, International Journal of Aeronautics and Astronautics, c. 2, sy 1, ss. 9–13, May. 2021, [çevrimiçi]. Erişim adresi: https://izlik.org/JA35ZY33GT
ISNAD
Güven, Türker Burak - Altun, Aziz Hakan - Doğan, Sercan. “An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans”. International Journal of Aeronautics and Astronautics 2/1 (01 Mayıs 2021): 9-13. https://izlik.org/JA35ZY33GT.
JAMA
1.Güven TB, Altun AH, Doğan S. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics. 2021;2:9–13.
MLA
Güven, Türker Burak, vd. “An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans”. International Journal of Aeronautics and Astronautics, c. 2, sy 1, Mayıs 2021, ss. 9-13, https://izlik.org/JA35ZY33GT.
Vancouver
1.Türker Burak Güven, Aziz Hakan Altun, Sercan Doğan. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics [Internet]. 01 Mayıs 2021;2(1):9-13. Erişim adresi: https://izlik.org/JA35ZY33GT

International Journal of Aeronautics and Astronautics Creative Commons Atıf-GayriTicari 4.0 Uluslararası Lisansı (CC BY NC) ile lisanslanmıştır.