Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2021, Cilt: 2 Sayı: 1, 9 - 13, 01.05.2021

Öz

Kaynakça

  • Eck,B., Fans, Design and Operation of Centrifugal, Axial Flow And Cross Flow Fans, First Edition, Biddles Ltd., Great Britain,1972.
  • Canbazoğlu,S., Fan Mühendisliği-1, First Edition, Aironn Fan Mühendisliği Teknik Yayın, Turkey, 2020.
  • Çakmanus, İ., Endüstriyel Fanlar Tasarım, İmalat ve Enerji Verimliliği, First Edition, TTMD Teknik Yayın No:23, Turkey,2009.
  • Elliot,N., and Nadel,S.,Realizing Energy Efficiency Opportunities in Industrial Fan and Pump Systems, Report Number A304,USA, 2003.
  • Waide,P., and Brunner,C., Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems, Working Paper, International Energy Agency, France,2011.
  • TEDAŞ, 2019 Yili Türkiye Elektrik Dağitimi Sektör Raporu, Turkey,2020.
  • Bleier,F., Fan Handbook Selection, Application and Design, First Edition, McGraw Hill,USA,1997.
  • Zhu, X., Lin, W., and Du, Z., 2004.Experimental and Numerical Investigation of the Flow Field in the Tip Region of an Axial Ventilation Fan. ASME. J. Fluids Engineering,127(2),299–307.
  • Li, Y., Liu, J., Ouyang, H., and Du, Z. 2008. Internal flow Mechanism and Experimental Research of Low-Pressure Axial fan with Forward-Skewed Blades. Journal of Hydrodynamics, Ser. B,20(3), 299–305.
  • Cho, L., Cha, B., and Cho, J. 2009. Experimental Study on the Three-Dimensional Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan. Journal of Fluid Science and Technology, 4, 200-209.
  • Munisamy,K., Govindasamy,R., and Thangaraju,S., 2012. Experimental and Numerical Investigation onto 1250mm Axial Fan. Applied Mechanics and Materials, 225(x), 91-96. doi:10.4028/www.scientific.net/AMM.225.91
  • Zhang, S., 2015. Experimental study on performance of contra-rotating axial flow fan. Int J Coal Sci Technol 2, 232–236.
  • Castegnaro, S., Masi,M., and Lazzaretto,A., 2018. Design and Testing of an ISO 5801 Inlet Chamber Test Rig and Related Issues with the Standard. FAN 2018 - International Conference on Fan Noise, Aerodynamics, Applications & Systems, April 2018, Darmstadt, Germany
  • ANSI/AMCA Standard 210-16, ASHRAE Standard 51-16, Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating, USA,2016
  • http://www.kayites.com/assets/upload/folder/publish/normal/kayites_20213317143302.pdf , (08.03.2021)

An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans

Yıl 2021, Cilt: 2 Sayı: 1, 9 - 13, 01.05.2021

Öz

The fact that fans are used in a large variety and wide areas today requires them to have a certain performance and quality. The test set-up to be used to determine the performance values of the fans should also be prepared and verified in accordance with standards such as ISO, ANSI / AMCA. In this study, a test set-up was designed and established in accordance with the ANSI / AMCA 210-16 standard. In order to ensure the accuracy of this test set-up, the static pressure values for different flow rates of the AXI500-5-25 model axial fan produced in a fan manufacturer company in Konya were measured, and data were obtained. The static pressure-flow rate performance curve obtained from the tests was compared with the manufacturer's catalog data. As the most important result in comparison, it was seen that the experimental and the catalog data were quite compatible. The highest difference between experimental and catalog data was obtained at the points where the flow rate is minimum and maximum. However, this difference was determined to be around 5%. With the results obtained in the study, it was determined that the accuracy of the experimental set-up designed and set up according to ANSI/AMCA 210-16 standard was ensured and it was suitable to be used for testing.

Kaynakça

  • Eck,B., Fans, Design and Operation of Centrifugal, Axial Flow And Cross Flow Fans, First Edition, Biddles Ltd., Great Britain,1972.
  • Canbazoğlu,S., Fan Mühendisliği-1, First Edition, Aironn Fan Mühendisliği Teknik Yayın, Turkey, 2020.
  • Çakmanus, İ., Endüstriyel Fanlar Tasarım, İmalat ve Enerji Verimliliği, First Edition, TTMD Teknik Yayın No:23, Turkey,2009.
  • Elliot,N., and Nadel,S.,Realizing Energy Efficiency Opportunities in Industrial Fan and Pump Systems, Report Number A304,USA, 2003.
  • Waide,P., and Brunner,C., Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems, Working Paper, International Energy Agency, France,2011.
  • TEDAŞ, 2019 Yili Türkiye Elektrik Dağitimi Sektör Raporu, Turkey,2020.
  • Bleier,F., Fan Handbook Selection, Application and Design, First Edition, McGraw Hill,USA,1997.
  • Zhu, X., Lin, W., and Du, Z., 2004.Experimental and Numerical Investigation of the Flow Field in the Tip Region of an Axial Ventilation Fan. ASME. J. Fluids Engineering,127(2),299–307.
  • Li, Y., Liu, J., Ouyang, H., and Du, Z. 2008. Internal flow Mechanism and Experimental Research of Low-Pressure Axial fan with Forward-Skewed Blades. Journal of Hydrodynamics, Ser. B,20(3), 299–305.
  • Cho, L., Cha, B., and Cho, J. 2009. Experimental Study on the Three-Dimensional Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan. Journal of Fluid Science and Technology, 4, 200-209.
  • Munisamy,K., Govindasamy,R., and Thangaraju,S., 2012. Experimental and Numerical Investigation onto 1250mm Axial Fan. Applied Mechanics and Materials, 225(x), 91-96. doi:10.4028/www.scientific.net/AMM.225.91
  • Zhang, S., 2015. Experimental study on performance of contra-rotating axial flow fan. Int J Coal Sci Technol 2, 232–236.
  • Castegnaro, S., Masi,M., and Lazzaretto,A., 2018. Design and Testing of an ISO 5801 Inlet Chamber Test Rig and Related Issues with the Standard. FAN 2018 - International Conference on Fan Noise, Aerodynamics, Applications & Systems, April 2018, Darmstadt, Germany
  • ANSI/AMCA Standard 210-16, ASHRAE Standard 51-16, Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating, USA,2016
  • http://www.kayites.com/assets/upload/folder/publish/normal/kayites_20213317143302.pdf , (08.03.2021)
Toplam 15 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Uzay Mühendisliği
Bölüm Araştırma Makaleleri
Yazarlar

Türker Burak Güven 0000-0003-0131-5621

Aziz Hakan Altun 0000-0002-1546-1104

Sercan Doğan

Yayımlanma Tarihi 1 Mayıs 2021
Gönderilme Tarihi 30 Mart 2021
Yayımlandığı Sayı Yıl 2021 Cilt: 2 Sayı: 1

Kaynak Göster

APA Güven, T. B., Altun, A. H., & Doğan, S. (2021). An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics, 2(1), 9-13.
AMA Güven TB, Altun AH, Doğan S. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics. Mayıs 2021;2(1):9-13.
Chicago Güven, Türker Burak, Aziz Hakan Altun, ve Sercan Doğan. “An Experimental Test Set-up With the ANSI / AMCA 210-16 Standard for Performance Analysis of Axial Fans”. International Journal of Aeronautics and Astronautics 2, sy. 1 (Mayıs 2021): 9-13.
EndNote Güven TB, Altun AH, Doğan S (01 Mayıs 2021) An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics 2 1 9–13.
IEEE T. B. Güven, A. H. Altun, ve S. Doğan, “An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans”, International Journal of Aeronautics and Astronautics, c. 2, sy. 1, ss. 9–13, 2021.
ISNAD Güven, Türker Burak vd. “An Experimental Test Set-up With the ANSI / AMCA 210-16 Standard for Performance Analysis of Axial Fans”. International Journal of Aeronautics and Astronautics 2/1 (Mayıs 2021), 9-13.
JAMA Güven TB, Altun AH, Doğan S. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics. 2021;2:9–13.
MLA Güven, Türker Burak vd. “An Experimental Test Set-up With the ANSI / AMCA 210-16 Standard for Performance Analysis of Axial Fans”. International Journal of Aeronautics and Astronautics, c. 2, sy. 1, 2021, ss. 9-13.
Vancouver Güven TB, Altun AH, Doğan S. An experimental test set-up with the ANSI / AMCA 210-16 standard for performance analysis of axial fans. International Journal of Aeronautics and Astronautics. 2021;2(1):9-13.

International Journal of Aeronautics and Astronautics Creative Commons Atıf-GayriTicari 4.0 Uluslararası Lisansı (CC BY NC) ile lisanslanmıştır.