Thermoluminescence Dosimeters Holder Cassette Design and 3D Printing

Cilt: 9 Sayı: 4 31 Aralık 2023
PDF İndir
EN

Thermoluminescence Dosimeters Holder Cassette Design and 3D Printing

Abstract

3-dimensional (3D) printing technology has been used in many fields and has taken a significant place in several applications. The ease of production, cheap cost, being able to produce the product most suitable for your needs, and easy accessibility of the 3D printer have enabled it to be used in many areas. This study emerged from the need for an apparatus to place thermoluminescence dosimeters (TLD) during the calibration of TLDs to be used to determine organ doses in fluoroscopy applications. In the study, the TLD holder cassette that specially designed in the SolidWorks program was printed from PLA material using the fused deposition modeling (FDM) technique with Creality Ender 3 S1 printer. With this 3D TLD holder cassette that designed and printed in accordance with the needs, we aimed to show the usability of the 3D printing technique in almost every field of applied sciences.

Keywords

Kaynakça

  1. [1] Sürmen, H. K. (2019). Eklemeli İmalat (3b Baski): Teknolojiler Ve Uygulamalar. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi. 24 (2): 373-392 . DOI: 10.17482/uumfd.519147.
  2. [2] Ecker, J.V., Kracalik, M., Hild, S., & Haider, A. (2017). 3D- Material Extrusion – Printing with Biopolymers: A Review. Chemical and Materials Engineering. 5(4): 83-96.
  3. [3] Aksözen, M. T., Yaray, K., Menteş, S., Gündoğ, M., Eroğlu, C.(2012). “Calibration of Gamma Rays With LiF Thermoluminescence Dosimeters”. Türk Onkoloji Dergisi, 27(1): 24-28.
  4. [4] Dönmez, S. (2017). Radyasyon Tespiti ve Ölçümü. Nucl Med Semin.3:172-177.
  5. [5] McKinlay, AF.(1981). Thermoluminescence dosimetry-medical physics handbook; 5. Çeviri: Aypar A, Akın E. Medikal fizik kitapları 5. Termolüminesans dozimetri. Adam Hilger Ltd; s. 57-123.
  6. [6] D’Avinio, V., Caruso, M., Arrichiello, C.et. al. (2020). Il Nuovo Cimento.43 C:142. DOI 10.1393/ncc/i2020-20142-0.
  7. [7] Suleiman, A. Theodorou,K., Vlychou, M. et al. (2007). “Radiation dose measurement and risk estimation for paediatric patients undergoing micturating cystourethrography”. The British Journal of Radiology, 80:731-737. https://doi.org/10.1259/bjr/16010686
  8. [8] Creality Ender 3 S1 3D printer technical features, https://www.porima3d.com/

Ayrıntılar

Birincil Dil

İngilizce

Konular

İnşaat Mühendisliği (Diğer)

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

30 Eylül 2023

Yayımlanma Tarihi

31 Aralık 2023

Gönderilme Tarihi

6 Temmuz 2023

Kabul Tarihi

7 Ağustos 2023

Yayımlandığı Sayı

Yıl 1970 Cilt: 9 Sayı: 4

Kaynak Göster

APA
Tunçman, D., Kesmezacar, F. F., Günay, O., Yeyin, N., Demir, Ö., Demir, Ph.d., M., & Akkuş, B. (2023). Thermoluminescence Dosimeters Holder Cassette Design and 3D Printing. International Journal of Computational and Experimental Science and Engineering, 9(4), 320-324. https://doi.org/10.22399/ijcesen.1323590