Araştırma Makalesi

Determination of the Radiation Dose Level in Different Slice Computerized Tomography

Cilt: 5 Sayı: 3 30 Kasım 2019
PDF İndir
EN

Determination of the Radiation Dose Level in Different Slice Computerized Tomography

Öz

Today, many imaging tools have emerged in the medical field using ionizing radiation. Computed tomography (CT) is regarded the most creative and  common modality among the other imaging devices. In CT imaging, radiation may scatter to the environment from the patient and the interaction medium. In this study, two CT scanners with  different slice numbers were used to measure the scatter radiation dose to the environment. Alderson rando phantom was utilized in the acquired CT exams as human body simulation. Radiation dose levels at different distances were determined by placing thermoluminescence dosimeters in the surrounding environment (at different distances) during phantom’s head-neck and thorax CT imaging. As a result, it has been found that the radiation dose varies between 13.90±1.96 µSv and 96.79±11.12 µSv in head and neck CT imaging. While, in thorax CT scan,  the radiation dose varies between 5.28±0.84 µSv and 20.63±1.76 µSv.

Anahtar Kelimeler

Kaynakça

  1. Health risks from exposure to low levels of ionizing radiationBEIR VII. Washington DC: National Academies Press, 2005.
  2. Mitelman F, Johansson B, Mertens FE. Mitelman database of chromosome aberrations in cancer. Cancer Genome Anatomy Project, 2007.
  3. Hall EJ, Brenner DJ. Cancer risks from diagnostic radiology. Br J Radiol.2008 May;81(965):362-78.
  4. Berrington de Gonzalez A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, Land C. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med. 2009 Dec 14;169(22):2071-7.
  5. What’s NEXT? Nationwide Evaluation of X-ray Trends: 2000 computed tomography. (CRCPD publication no. NEXT_2000CTT.) Conference of Radiation Control Program Directors, Department of Health and Human Services, 2006
  6. Mettler FA Jr, Wiest PW, Locken JA, Kelsey CA. CT scanning: patterns of use and dose. J Radiol Prot 2000;20:353-9.
  7. White KS. Helical/spiral CT scanning: a pediatric radiology perspective. Pediatr Radiol 1996;26:5-14.
  8. Linton OW, Mettler FA Jr. National conference on dose reduction in CT, with an emphasis on pediatric patients. AJR Am J Roentgenol 2003;181:321-9.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Kasım 2019

Gönderilme Tarihi

24 Temmuz 2019

Kabul Tarihi

18 Eylül 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 5 Sayı: 3

Kaynak Göster

APA
Günay, O., Gündoğdu, Ö., Demir, M., Abuqbeitah, M., Yaşar, D., Aközcan, S., Kapdan, E., & Yarar, O. (2019). Determination of the Radiation Dose Level in Different Slice Computerized Tomography. International Journal of Computational and Experimental Science and Engineering, 5(3), 119-123. https://doi.org/10.22399/ijcesen.595645
AMA
1.Günay O, Gündoğdu Ö, Demir M, vd. Determination of the Radiation Dose Level in Different Slice Computerized Tomography. IJCESEN. 2019;5(3):119-123. doi:10.22399/ijcesen.595645
Chicago
Günay, Osman, Özcan Gündoğdu, Mustafa Demir, vd. 2019. “Determination of the Radiation Dose Level in Different Slice Computerized Tomography”. International Journal of Computational and Experimental Science and Engineering 5 (3): 119-23. https://doi.org/10.22399/ijcesen.595645.
EndNote
Günay O, Gündoğdu Ö, Demir M, Abuqbeitah M, Yaşar D, Aközcan S, Kapdan E, Yarar O (01 Kasım 2019) Determination of the Radiation Dose Level in Different Slice Computerized Tomography. International Journal of Computational and Experimental Science and Engineering 5 3 119–123.
IEEE
[1]O. Günay vd., “Determination of the Radiation Dose Level in Different Slice Computerized Tomography”, IJCESEN, c. 5, sy 3, ss. 119–123, Kas. 2019, doi: 10.22399/ijcesen.595645.
ISNAD
Günay, Osman - Gündoğdu, Özcan - Demir, Mustafa - Abuqbeitah, Mohammad - Yaşar, Doğan - Aközcan, Serpil - Kapdan, Enis - Yarar, Onur. “Determination of the Radiation Dose Level in Different Slice Computerized Tomography”. International Journal of Computational and Experimental Science and Engineering 5/3 (01 Kasım 2019): 119-123. https://doi.org/10.22399/ijcesen.595645.
JAMA
1.Günay O, Gündoğdu Ö, Demir M, Abuqbeitah M, Yaşar D, Aközcan S, Kapdan E, Yarar O. Determination of the Radiation Dose Level in Different Slice Computerized Tomography. IJCESEN. 2019;5:119–123.
MLA
Günay, Osman, vd. “Determination of the Radiation Dose Level in Different Slice Computerized Tomography”. International Journal of Computational and Experimental Science and Engineering, c. 5, sy 3, Kasım 2019, ss. 119-23, doi:10.22399/ijcesen.595645.
Vancouver
1.Osman Günay, Özcan Gündoğdu, Mustafa Demir, Mohammad Abuqbeitah, Doğan Yaşar, Serpil Aközcan, Enis Kapdan, Onur Yarar. Determination of the Radiation Dose Level in Different Slice Computerized Tomography. IJCESEN. 01 Kasım 2019;5(3):119-23. doi:10.22399/ijcesen.595645

Cited By

Dose Calibrator Measurements in the Case of Voltage Fluctuations

International Journal of Computational and Experimental Science and Engineering

https://doi.org/10.22399/ijcesen.1303582

Computation of Neutron Coefficients for B2O3 reinforced Composite

International Journal of Computational and Experimental Science and Engineering

https://doi.org/10.22399/ijcesen.1290497