This paper includes the measurement of the concentrations of natural radioactive isotopes of 238U, 232Th, and radiation dose rates for selected areas of Wasit province.GR-460 system has been used for the radiological survey operations, it is a portable system, installed inside a minibus and inside the system, there is a Sodium Iodide Detector (NaI), that has the ability to measure the concentrations of natural radioactive isotopes in (ppm) unit and measure the radiation dose rates in µR/h unit. The measurement results showed the absence of any significant increase in the 238U and 232Th concentration where the concentration of isotopes 238U and 232Th, were 3.35 and 5.46 ppm respectively, it is authorized and acceptable. The values of radiation dose rates ranged between 45-65 ոSv/հ, and all these values are within the natural radiation background. Eleven radioactive sources type 226Ra have been detected beside destroyed industrial facility because of the war 2003 they had been used in the lightning arresters technology in the last regime. These sources treated and placed in armored containers and taken to the Iraqi main store (Iraqi Organization of Atomic Energy Site), the radiation dose measurements ranged between 72- 48 µR/h, which is higher than the natural radiation background.
GR-460 system Radiation does rates Concentration of natural isotopes Wasit province
Birincil Dil | İngilizce |
---|---|
Bölüm | Research Articles |
Yazarlar | |
Yayımlanma Tarihi | 30 Kasım 2021 |
Gönderilme Tarihi | 6 Mart 2021 |
Kabul Tarihi | 24 Kasım 2021 |
Yayımlandığı Sayı | Yıl 2021 Cilt: 7 Sayı: 3 |