Araştırma Makalesi

Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation

Cilt: 8 Sayı: 3 22 Eylül 2023
PDF İndir
EN

Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation

Abstract

This study aimed to assess the effectiveness of an ejector refrigeration cycle, using a laboratory-scale experimental system operating in different configurations. The investigated configurations consisted of a conventional vapour compression refrigeration (CVCR) system and a dual evaporator ejector system (DEES) operated in two modes: DEES with a single thermal expansion valve (DEESA) and DEES with dual thermal expansion valves (DEESB). The findings revealed that the utilization of the ejector enhanced the refrigerant's mass flow rate. Additionally, the DEESA configuration achieved higher cooling capacities compared to the CVCR. Moreover, the DEESA configuration achieved up to 21% higher coefficient of performance (COP) values. On the other hand, when the system was operated in the DEESB configuration, it yielded lower evaporation temperatures and higher superheating degrees in comparison to DEESA. Based on the evaluations, it can be concluded that the ejector operates more efficiently in systems with dual evaporators, thereby making positive contributions to overall system performance.

Keywords

Destekleyen Kurum

Yalova Üniversitesi

Proje Numarası

2021/YL/ 0020, 2019/AP/0013

Teşekkür

We are grateful to Yalova University due to financial support (Project No. 2021/YL/ 0020 and 2019/AP/0013).

Kaynakça

  1. L. DJ. The Role of Refrigeration in the Global Economy (2019), 38th Note on Refrigeration Technologies. International Institute of Refrigeration, France, Paris, 2019.
  2. Direk M, Soylu E. The effect of internal heat exchanger using R1234ze(E) as an alternative refrigerant in a mobile air-conditioning system. Journal of Mechanical Engineering 2018;64:114-120.
  3. Erdinc MT. Two-evaporator refrigeration system integrated with expander-compressor booster. International Journal of Refrigeration 2023; 0140-7007.
  4. Erdinc MT. Performance simulation of expander-compressor boosted subcooling refrigeration system. International Journal of Refrigeration 2023;149:237-247.
  5. Prabakaran R, Lal DM, Kim SC. A state of art review on future low global warming potential refrigerants and performance augmentation methods for vapour compression based mobile air conditioning system. Journal of Thermal Analysis and Calorimetry 2023;148:417-449.
  6. Caliskan O, Ersoy HK. Energy analysis and performance comparison of transcritical CO2 supermarket refrigeration cycles. The Journal of Supercritical Fluids 2022;189:105698.
  7. Oshitani H, Yamanaka Y, et al. Vapor Compression Cycle Having Ejector. United States Patent 2007; Patent No. US007254961B2.
  8. Lawrence N, Elbel S. Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf. International Journal of Refrigeration 2014;38:310-322.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Makine Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

22 Eylül 2023

Gönderilme Tarihi

3 Mayıs 2023

Kabul Tarihi

27 Temmuz 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 8 Sayı: 3

Kaynak Göster

APA
Üğüdür, B., İşkan, Ü., & Direk, M. (2023). Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation. International Journal of Energy Studies, 8(3), 315-330. https://doi.org/10.58559/ijes.1291259
AMA
1.Üğüdür B, İşkan Ü, Direk M. Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation. International Journal of Energy Studies. 2023;8(3):315-330. doi:10.58559/ijes.1291259
Chicago
Üğüdür, Batuhan, Ümit İşkan, ve Mehmet Direk. 2023. “Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation”. International Journal of Energy Studies 8 (3): 315-30. https://doi.org/10.58559/ijes.1291259.
EndNote
Üğüdür B, İşkan Ü, Direk M (01 Eylül 2023) Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation. International Journal of Energy Studies 8 3 315–330.
IEEE
[1]B. Üğüdür, Ü. İşkan, ve M. Direk, “Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation”, International Journal of Energy Studies, c. 8, sy 3, ss. 315–330, Eyl. 2023, doi: 10.58559/ijes.1291259.
ISNAD
Üğüdür, Batuhan - İşkan, Ümit - Direk, Mehmet. “Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation”. International Journal of Energy Studies 8/3 (01 Eylül 2023): 315-330. https://doi.org/10.58559/ijes.1291259.
JAMA
1.Üğüdür B, İşkan Ü, Direk M. Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation. International Journal of Energy Studies. 2023;8:315–330.
MLA
Üğüdür, Batuhan, vd. “Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation”. International Journal of Energy Studies, c. 8, sy 3, Eylül 2023, ss. 315-30, doi:10.58559/ijes.1291259.
Vancouver
1.Batuhan Üğüdür, Ümit İşkan, Mehmet Direk. Performance analysis of dual-evaporator ejector refrigeration system in different configurations: Experimental investigation. International Journal of Energy Studies. 01 Eylül 2023;8(3):315-30. doi:10.58559/ijes.1291259

Cited By