Araştırma Makalesi

Investigation of using low GWP alternatives to replace R404A in the refrigeration system

Cilt: 8 Sayı: 3 22 Eylül 2023
PDF İndir
EN

Investigation of using low GWP alternatives to replace R404A in the refrigeration system

Abstract

In recent years, the use of refrigerants, which increase the global warming potential by creating a greenhouse effect, has begun to be restricted in refrigeration systems. More environmentally friendly and more efficient synthetic mixtures and natural refrigerants are replacing refrigerants with high global warming potential. In this study, R404A refrigerant, which is frequently preferred in refrigeration systems and has a high global warming potential, was discussed. Six different refrigerants (R407H, R448A, R454C, R468A, R290, R1270) that could be alternatives to R404A refrigerant were examined and compared with R404A. Energy, exergy, and environmental analyzes were performed under the same conditions according to -10 ℃, -5 ℃, and 0 ℃ evaporating temperatures. Among the refrigerants, R290 had the best value with a coefficient of performance of 4.11 and an exergy efficiency of 40.04%. The values of R1270 refrigerant were also almost the same as R290. Even if R468A shows the lowest performance, it can be preferred over R404A because its global warming potential is lower than R404A.

Keywords

Kaynakça

  1. [1] López-Belchí A. Assessment of a mini-channel condenser at high ambient temperatures based on experimental measurements working with R134a, R513A and R1234yf. Applied Thermal Engineering 2019; 155: 341–353.
  2. [2] Hepbasli A. Low exergy heating and cooling systems for sustainable buildings and societies. Renewable and Sustainable Energy Reviews 2012; 16 (1): 73–104.
  3. [3] Kharseh M, Altorkmany L, Al-Khawaj M, Hassani F. Warming impact on energy use of HVAC system in buildings of different thermal qualities and in different climates. Energy Conversion and Managment, 2014; 81: 106–111.
  4. [4] Mota-Babiloni A, Makhnatch P. Predictions of European refrigerants place on the market following F-gas regulation restrictions. International Journal of Refrigeration 2021; 127: 101-110.
  5. [5] Cabello R, Sánchez D, Llopis R, Andreu-Nacher A, Calleja-Anta D. Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270. International Journal of Refrigeration 2022; 137: 22-33.
  6. [6] Makhnatch P, Mota-Babiloni A, Rogstam J, Khodabandeh R. Retrofit of lower GWP alternative R449A into an existing R404A indirect supermarket refrigeration system. International Journal of Refrigeration 2017; 76: 184-192.
  7. [7] Oruc V, Devecioglu AG. Experimental investigation on the low-GWP HFC/HFO blends R454A and R454C in a R404A refrigeration system. International Journal of Refrigeration 2021; 128: 242-251.
  8. [8] Mota-Babiloni A, Navarro-Esbrí J, Peris B, Molés F, Verdú G. Experimental evaluation of R448A as R404A lower-GWP alternative in refrigeration systems. Energy Conversion and Management 2015; 105: 756-762.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Enerji , Enerji Sistemleri Mühendisliği (Diğer)

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

22 Eylül 2023

Gönderilme Tarihi

31 Temmuz 2023

Kabul Tarihi

17 Ağustos 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 8 Sayı: 3

Kaynak Göster

APA
Koşan, M. (2023). Investigation of using low GWP alternatives to replace R404A in the refrigeration system. International Journal of Energy Studies, 8(3), 453-464. https://doi.org/10.58559/ijes.1335092
AMA
1.Koşan M. Investigation of using low GWP alternatives to replace R404A in the refrigeration system. International Journal of Energy Studies. 2023;8(3):453-464. doi:10.58559/ijes.1335092
Chicago
Koşan, Meltem. 2023. “Investigation of using low GWP alternatives to replace R404A in the refrigeration system”. International Journal of Energy Studies 8 (3): 453-64. https://doi.org/10.58559/ijes.1335092.
EndNote
Koşan M (01 Eylül 2023) Investigation of using low GWP alternatives to replace R404A in the refrigeration system. International Journal of Energy Studies 8 3 453–464.
IEEE
[1]M. Koşan, “Investigation of using low GWP alternatives to replace R404A in the refrigeration system”, International Journal of Energy Studies, c. 8, sy 3, ss. 453–464, Eyl. 2023, doi: 10.58559/ijes.1335092.
ISNAD
Koşan, Meltem. “Investigation of using low GWP alternatives to replace R404A in the refrigeration system”. International Journal of Energy Studies 8/3 (01 Eylül 2023): 453-464. https://doi.org/10.58559/ijes.1335092.
JAMA
1.Koşan M. Investigation of using low GWP alternatives to replace R404A in the refrigeration system. International Journal of Energy Studies. 2023;8:453–464.
MLA
Koşan, Meltem. “Investigation of using low GWP alternatives to replace R404A in the refrigeration system”. International Journal of Energy Studies, c. 8, sy 3, Eylül 2023, ss. 453-64, doi:10.58559/ijes.1335092.
Vancouver
1.Meltem Koşan. Investigation of using low GWP alternatives to replace R404A in the refrigeration system. International Journal of Energy Studies. 01 Eylül 2023;8(3):453-64. doi:10.58559/ijes.1335092

Cited By