Optimization of Cooling Load for Different Greenhouse Models in Malaysia

Öz

In this paper, the building energy analysis program (DOE-2.1E) is used to investigate the reduction in thermal gains and cooling load for agricultural greenhouse. The greenhouse  located in Kuala Lumpur (latitude =3.12o and longitude = -101.60o) and designed with a modified arch roof type with a length of  6 m, width of 3 m, gutter and gable heights of 2.4 m and 0.6 m, respectively. Three models such as:  (1) an internal, movable 50% shade screen mounted directly above the floor, with a span of 3 m from gutter to gutter; (2) a double envelope roof that is elevated 0.6 m from the ceiling; and (3) an internal, movable shade screen with a double envelope roof have been selected for comparison with the original greenhouse. The comparison is based on thermal gains and cooling load. The results showed that the internal, movable 50% shade screen was found to be the most effective in reducing maximum cooling load requirement (at 14.89%); the double envelope roof models with and without shading reduced maximum cooling load by 10.11 % and 9.39 %, respectively.

Anahtar Kelimeler

Kaynakça

  1. Dilip Jain, Gopal Nath Tiwari, “Modeling and optimal design of evaporative cooling system in controlled environment greenhouse”, Energy Convers. Manage, vol.43, pp. 2235-2250, February 2002.
  2. José Pérez-Alonso,Ángel J. Callejón-Ferre, Ángel Carreño-Ortega, Julián Sánchez-Hermosilla, “Approach to the evaluation of the thermal work environment in the greenhouse-construction industry of SE Spain”, Build Environ, vol.46, pp. 1725-1734,March 2011.
  3. Elisabeth Gratia, Andre´ De Herde, “Greenhouse effect in double-skin façade”, Energy Build, vol.39, pp. 199- , July 2007.
  4. F. A. Hashem, M. A. Medany, E. M. Abd El-Moniem, M. M. F. Abdallah, “Influence of green-house cover on potential requirements”, Anna. Agricul. Sci, vol.56, pp. 49-55, August 2011. and cucumber water
  5. Keesung Kim, Jeong-Yeol Yoon, Hyuck-Jin Kwon, Jin- Hee Han, Jung Eek Son, Sang-Woon Nam, Gene A. Giacomelli, In-Bok Lee, “3-D CFD analysis of relative humidity distribution in greenhouse with a fog cooling system and refrigerative dehumidifiers”, Biosyst. Eng, vol. 100, pp. 245-255, May 2008.
  6. Perdigones, J. L. Garcı´a, A. Romero, A. Rodrı´guez, L. Luna, C. Raposo, S. de la Plaza, “Cooling strategies for greenhouses in summer: Control of fogging by pulse width modulation”, Biosyst. Eng, vol.99, pp. 573-586, March 2008.
  7. M. Teitel, M. Atias, M. Barak, “Gradients of temperature, humidity and CO2 a long a fan-ventilated greenhouse”, Biosyst. Eng, vol.106, 166-174, April 2010.
  8. H. Toida, K. Ohyama, T. Kozai, Handarto, M. Hayashi, “A Method for measuring Dry bulb Temperatures during the Operation of a Fog System for Greenhouse Cooling”, Biosyst. Eng, vol.93, pp. 347–351, January 2006.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Abdulrahman Th. Mohammad Bu kişi benim

Sohif Bin Mat Bu kişi benim

M. S. Alrubaih Bu kişi benim

Abduljalil A. Al-abidi Bu kişi benim

Yayımlanma Tarihi

1 Mart 2014

Gönderilme Tarihi

3 Şubat 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2014 Cilt: 4 Sayı: 1

Kaynak Göster

APA
Mohammad, A. T., Mat, S. B., Alrubaih, M. S., & Al-abidi, A. A. (2014). Optimization of Cooling Load for Different Greenhouse Models in Malaysia. International Journal Of Renewable Energy Research, 4(1), 42-48. https://izlik.org/JA77BS57RL
AMA
1.Mohammad AT, Mat SB, Alrubaih MS, Al-abidi AA. Optimization of Cooling Load for Different Greenhouse Models in Malaysia. International Journal Of Renewable Energy Research. 2014;4(1):42-48. https://izlik.org/JA77BS57RL
Chicago
Mohammad, Abdulrahman Th., Sohif Bin Mat, M. S. Alrubaih, ve Abduljalil A. Al-abidi. 2014. “Optimization of Cooling Load for Different Greenhouse Models in Malaysia”. International Journal Of Renewable Energy Research 4 (1): 42-48. https://izlik.org/JA77BS57RL.
EndNote
Mohammad AT, Mat SB, Alrubaih MS, Al-abidi AA (01 Mart 2014) Optimization of Cooling Load for Different Greenhouse Models in Malaysia. International Journal Of Renewable Energy Research 4 1 42–48.
IEEE
[1]A. T. Mohammad, S. B. Mat, M. S. Alrubaih, ve A. A. Al-abidi, “Optimization of Cooling Load for Different Greenhouse Models in Malaysia”, International Journal Of Renewable Energy Research, c. 4, sy 1, ss. 42–48, Mar. 2014, [çevrimiçi]. Erişim adresi: https://izlik.org/JA77BS57RL
ISNAD
Mohammad, Abdulrahman Th. - Mat, Sohif Bin - Alrubaih, M. S. - Al-abidi, Abduljalil A. “Optimization of Cooling Load for Different Greenhouse Models in Malaysia”. International Journal Of Renewable Energy Research 4/1 (01 Mart 2014): 42-48. https://izlik.org/JA77BS57RL.
JAMA
1.Mohammad AT, Mat SB, Alrubaih MS, Al-abidi AA. Optimization of Cooling Load for Different Greenhouse Models in Malaysia. International Journal Of Renewable Energy Research. 2014;4:42–48.
MLA
Mohammad, Abdulrahman Th., vd. “Optimization of Cooling Load for Different Greenhouse Models in Malaysia”. International Journal Of Renewable Energy Research, c. 4, sy 1, Mart 2014, ss. 42-48, https://izlik.org/JA77BS57RL.
Vancouver
1.Abdulrahman Th. Mohammad, Sohif Bin Mat, M. S. Alrubaih, Abduljalil A. Al-abidi. Optimization of Cooling Load for Different Greenhouse Models in Malaysia. International Journal Of Renewable Energy Research [Internet]. 01 Mart 2014;4(1):42-8. Erişim adresi: https://izlik.org/JA77BS57RL