This paper presents sizing and evaluation of a standalone photovoltaic system for residential load. Peak Sun Hour method is used to determine photovoltaic panel and battery capacity, then the sizing results is tested and evaluated using hourly time-step transient simulation model by using TRNSYS 16.0. The results shows for typical Malaysian terraced house that have about 6 kWh daily electricity load, the photovoltaic system requirement consist of 1.9 kWp photovoltaic panel and 2200 Ah battery capacity for a 24V system.
Photovoltaic system sizing peak sun hour transient simulation
| Birincil Dil | İngilizce |
|---|---|
| Yazarlar | |
| Yayımlanma Tarihi | 1 Mart 2014 |
| Yayımlandığı Sayı | Yıl 2014 Cilt: 4 Sayı: 1 |