BibTex RIS Kaynak Göster

Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site

Yıl 2013, Cilt: 3 Sayı: 4, 861 - 871, 01.12.2013
https://izlik.org/JA56DU27YR

Öz

This paper explores the possibility of hybridizing the diesel generator source system with renewable energy sources and demonstrate the potential of renewable energies to replace (partially) diesel as a source of power for mobile base station sites. The concept of hybridizing the diesel generator is to reduce both the operating cost and the quantity of different air pollutants. The patterns of load consumption by mobile base station are studied and suitably modeled for optimization using Hybrid Optimization Model for Electric Renewables (HOMER) software. The proposed Hybrid (Solar & Hydro) + DG system was simulated using the model which results in four different topologies. The solution with the highest optimization value is considered to be the best energy option (solution) for the Base Station Site. From the simulation results, the PV/Hydro-Diesel system solution has the highest optimization value. It saves $15,961,777 and 70.553 tonnes of CO2 when compared with diesel only.

Yıl 2013, Cilt: 3 Sayı: 4, 861 - 871, 01.12.2013
https://izlik.org/JA56DU27YR

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Yazarlar

Vincent Anayochukwu Ani

Anthony Ndubueze Nzeako Bu kişi benim

Yayımlanma Tarihi 1 Aralık 2013
IZ https://izlik.org/JA56DU27YR
Yayımlandığı Sayı Yıl 2013 Cilt: 3 Sayı: 4

Kaynak Göster

APA Ani, V. A., & Nzeako, A. N. (2013). Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site. International Journal Of Renewable Energy Research, 3(4), 861-871. https://izlik.org/JA56DU27YR
AMA 1.Ani VA, Nzeako AN. Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site. International Journal Of Renewable Energy Research. 2013;3(4):861-871. https://izlik.org/JA56DU27YR
Chicago Ani, Vincent Anayochukwu, ve Anthony Ndubueze Nzeako. 2013. “Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site”. International Journal Of Renewable Energy Research 3 (4): 861-71. https://izlik.org/JA56DU27YR.
EndNote Ani VA, Nzeako AN (01 Aralık 2013) Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site. International Journal Of Renewable Energy Research 3 4 861–871.
IEEE [1]V. A. Ani ve A. N. Nzeako, “Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site”, International Journal Of Renewable Energy Research, c. 3, sy 4, ss. 861–871, Ara. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA56DU27YR
ISNAD Ani, Vincent Anayochukwu - Nzeako, Anthony Ndubueze. “Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site”. International Journal Of Renewable Energy Research 3/4 (01 Aralık 2013): 861-871. https://izlik.org/JA56DU27YR.
JAMA 1.Ani VA, Nzeako AN. Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site. International Journal Of Renewable Energy Research. 2013;3:861–871.
MLA Ani, Vincent Anayochukwu, ve Anthony Ndubueze Nzeako. “Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site”. International Journal Of Renewable Energy Research, c. 3, sy 4, Aralık 2013, ss. 861-7, https://izlik.org/JA56DU27YR.
Vancouver 1.Ani VA, Nzeako AN. Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site. International Journal Of Renewable Energy Research [Internet]. 01 Aralık 2013;3(4):861-7. Erişim adresi: https://izlik.org/JA56DU27YR