Abstract

Combination of Savonius and Darrieus type Vertical Axis Wind Turbine (VAWT) rotors possess many advantages over their individual designs, like low starting torque, high power coefficient, low cut-in wind speed etc.  However, there is still a need to do more research on such combination of rotors for their viability in the built environment where wind speed is low. In this paper, an attempt is made to measure the performance of a three-bladed combined Darrieus-Savonius rotor, with Darrieus mounted on top of Savonius rotor, for overlap variations from 10.8% to 25.8%. Power coefficients (Cp) and torque coefficients (Ct) were calculated in a low range of Tip Speed Ratio for each overlap condition. It is found that Cp increases with the increase of overlap. However, there is an optimum value of overlap for which, Cp is maximum, beyond this, Cp starts decreasing. The similar trend is observed for Ct as well. The maximum Cp of 0.53 is obtained at 0.604 Tip Speed Ratio (TSR) for an optimum 16.8% overlap. The performance of the rotor is also compared with another version of this hybrid design with Savonius mounted on top of Darrieus rotor. The present Darrieus-Savonius rotor can be suitably placed in the built environment where it can harness more power from wind and, at the same time, would self-start in low wind condition prevalent in such environment.

Keywords

Kaynakça

  1. Global wind energy market as of 2006. Press release of Global www.gwec.net/publications/global-wind-report-2 (2010 accessed 9 July 2006). Council (GWEC),
  2. Global wind energy market as of 2010. Press release of Global Wind Energy Council (GWEC), M.H. Model & characteristics of S-rotor wind mills. Wind Engg. J 1988; 12: 59-75. prototype performance
  3. Grinspan A.S, Kumar P.S, Mahanta P, Saha U.K, Rao D.V.R and Bhanu, G.V. Design, development & testing of Savonius wind turbine rotor with twisted blades. In: 28th National Conference on Fluid Mechanics and Fluid Power, Chandigarh, India, Dec 13-15 2001, pp 428-431.
  4. Saha U.K and Rajkumar M.J. On the performance analysis of Savonius rotor with twisted blades. Renewable Energy J 2006; 31(11): 1776-1788.
  5. Modi V.J and Fernando M.S.U.K. On the performance of the Savonius wind turbine. Solar Engg. J 1989; 11: 71- 76.
  6. Alexander A.J and Holownia B.P. Wind tunnel tests on a Savonius turbine. Industrial Aerodynamics J 1978; 3: 343-351.
  7. Saylers A.T. Blade configuration optimization & performance characteristics of a simple Savonius rotor. Institute of Mechanical Engineers J 1985; 199: 185-191.
  8. Blackwell B.F, Sheldahl R.E and Feltz L.V. Wind tunnel performance data for two & three bucket S-rotors. Energy J 1978; 2: 160-164.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Kaushal Kumar Sharma Bu kişi benim

Agnimitra Biswas Bu kişi benim

Rajat Gupta Bu kişi benim

Yayımlanma Tarihi

1 Aralık 2013

Gönderilme Tarihi

3 Şubat 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2013 Cilt: 3 Sayı: 4

Kaynak Göster

APA
Sharma, K. K., Biswas, A., & Gupta, R. (2013). Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor. International Journal Of Renewable Energy Research, 3(4), 885-891. https://izlik.org/JA86PR99WF
AMA
1.Sharma KK, Biswas A, Gupta R. Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor. International Journal Of Renewable Energy Research. 2013;3(4):885-891. https://izlik.org/JA86PR99WF
Chicago
Sharma, Kaushal Kumar, Agnimitra Biswas, ve Rajat Gupta. 2013. “Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor”. International Journal Of Renewable Energy Research 3 (4): 885-91. https://izlik.org/JA86PR99WF.
EndNote
Sharma KK, Biswas A, Gupta R (01 Aralık 2013) Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor. International Journal Of Renewable Energy Research 3 4 885–891.
IEEE
[1]K. K. Sharma, A. Biswas, ve R. Gupta, “Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor”, International Journal Of Renewable Energy Research, c. 3, sy 4, ss. 885–891, Ara. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA86PR99WF
ISNAD
Sharma, Kaushal Kumar - Biswas, Agnimitra - Gupta, Rajat. “Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor”. International Journal Of Renewable Energy Research 3/4 (01 Aralık 2013): 885-891. https://izlik.org/JA86PR99WF.
JAMA
1.Sharma KK, Biswas A, Gupta R. Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor. International Journal Of Renewable Energy Research. 2013;3:885–891.
MLA
Sharma, Kaushal Kumar, vd. “Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor”. International Journal Of Renewable Energy Research, c. 3, sy 4, Aralık 2013, ss. 885-91, https://izlik.org/JA86PR99WF.
Vancouver
1.Kaushal Kumar Sharma, Agnimitra Biswas, Rajat Gupta. Performance Measurement of a Three-Bladed Combined Darrieus-Savonius Rotor. International Journal Of Renewable Energy Research [Internet]. 01 Aralık 2013;3(4):885-91. Erişim adresi: https://izlik.org/JA86PR99WF