Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test
Öz
Various imaging devices are used for diagnostic and diagnostic purposes in radiology units of hospitals. Most of these devices are stationary in a room while others can be moved in a portable manner. The most common of these is the portable device that enables the in-patient imaging of the patients. This study was conducted to increase the awareness of light-beam field alignment, which changes very quickly depending on the frequency of use of portable x-ray devices, by controlling it with periodic maintenance of 2-3 months. The study was conducted using 5 portable devices and 1 fixed x-ray device. In the first stage, images were taken in the standard field and focus-object distance by adhering to the quality controls of the radiation generating devices. Measurements were made in the images where incompatibility was determined and the amount of shift was calculated. At the end of 3 separate 3-month measurements, the shift of the center of the field was ignored in the first measurements made with portable devices, and the shift quantities were found to be less than 2% of focus-object distance. At later measurements, more than 2% shifts were obtained in the areas of the most frequently used devices. With reference to the data obtained as a result of these measurements, the necessary interventions are expected to be made in the device
Anahtar Kelimeler
Kaynakça
- Bor D. (2016). Radyasyon : Sağlık riskleri ve tanısal incelemelerde korunma. Ankara: Dünya Tıp.
- Anonymous. (1991). Standardized methods for measuring diagnostic x-ray exposures (Report No:31). New York: AAPM.
- Erdamar A. (2001). Konvansiyonel ışın sistemlerinde kalite kontrol uygulamalarının standardizasyonu. Yüksek Lisans Tezi. Ankara Üniversitesi Fen Bilimleri Enstitüsü, Ankara.
- Gary J.E., Winkler N.T., Stears J., Frank E.D. (1983). Quality control in diagnostic imaging. An Aspen Publication.
- http://www.taek.gov.tr/belgeler-formlar/mevzuat/yonetmelikler/radyasyon-guvenligi/radyasyonguvenligi-yonetmeligi/ (Eğitim Bilimleri: 23/09/2017)
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
1 Ocak 2018
Gönderilme Tarihi
-
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2018 Cilt: 3 Sayı: 1
APA
Nur, S., & Toy, A. (2018). Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test. Uluslararası Medeniyet Çalışmaları Dergisi, 3(1), 411-417. https://doi.org/10.26899/inciss.58</doi>
AMA
1.Nur S, Toy A. Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test. INCISS. 2018;3(1):411-417. doi:10.26899/inciss.58</doi>
Chicago
Nur, Süreyya, ve Aslı Toy. 2018. “Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test”. Uluslararası Medeniyet Çalışmaları Dergisi 3 (1): 411-17. https://doi.org/10.26899/inciss.58</doi>
EndNote
Nur S, Toy A (01 Ocak 2018) Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test. Uluslararası Medeniyet Çalışmaları Dergisi 3 1 411–417.
IEEE
[1]S. Nur ve A. Toy, “Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test”, INCISS, c. 3, sy 1, ss. 411–417, Oca. 2018, doi: 10.26899/inciss.58</doi>
ISNAD
Nur, Süreyya - Toy, Aslı. “Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test”. Uluslararası Medeniyet Çalışmaları Dergisi 3/1 (01 Ocak 2018): 411-417. https://doi.org/10.26899/inciss.58</doi>
JAMA
1.Nur S, Toy A. Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test. INCISS. 2018;3:411–417.
MLA
Nur, Süreyya, ve Aslı Toy. “Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test”. Uluslararası Medeniyet Çalışmaları Dergisi, c. 3, sy 1, Ocak 2018, ss. 411-7, doi:10.26899/inciss.58</doi>
Vancouver
1.Süreyya Nur, Aslı Toy. Quality Control in the Portable X-Ray Appliances used by Radiodiagnostic: The Importance of Periodic Measurement of the Light-Beam Field Test. INCISS. 01 Ocak 2018;3(1):411-7. doi:10.26899/inciss.58</doi>