Araştırma Makalesi

COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A

Cilt: 39 Sayı: 1 30 Nisan 2019
  • Mehmet Direk
  • Fikret Yüksel
PDF İndir
EN TR

COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A

Öz

In this study, the use of R1234ze(E), R152a and R444a as alternative to R134a in a mobile air conditioning (MAC) system are tested. The performance characteristics of R134a, R444a, R1234ze(E) and R152a were experimentally examined in a MAC system by changing the air temperatures. Besides, the influence of compressor volume when the system operates with R1234ze(E) was investigated. The results show that the heating performance of R152a are higher than those obtained from R134a, R444a, R1234ze(E). Additionally, R1234ze(E) has lowest heating capacities among the low GWP refrigerants investigated. The heating performance of R1234ze(E) increased along with increasing the total compressor volume. Finally, R444a, R152a and R1234ze(E) can be used as alternative to R134a in MAC systems when the necessary improvements are made.

Anahtar Kelimeler

Kaynakça

  1. American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2013, Standard 34 Designation and Safety Classification of Refrigerants, ASHRAE.
  2. Bellocchi S., Guizzi G. L., Manno M., Salvatori M. and Zaccagnini A., 2018, Reversible heat pump HVAC system with regenerative heat exchanger for electric vehicles: Analysis of its impact on driving range, Applied Thermal Engineering, 129, 290–305.
  3. Direk M. and Soylu E., 2018, The Effect of Internal Heat Exchanger Using R1234ze (E) as an Alternative Refrigerant in a Mobile Air-Conditioning System, Strojniški vestnik-Journal of Mechanical Engineering, 64, 114-120.
  4. Devecioğlu A. G. and Oruç V., 2017, An analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systems, Thermal Science and Engineering Progress, 1, 1–5.
  5. European Parliament and the Council, 2014, No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing regulation (EC) No 842/2006 text with EEA relevance, Journal of the European Union, L 150/195–230.
  6. Janković Z., Atienza J. S. and Suárez J. A. M., 2015, Thermodynamic and heat transfer analyses for R1234yf and R1234ze (E) as drop-in replacements for R134a in a small power refrigerating system, Applied Thermal Engineering, 80, 42–54.
  7. Hoşöz M. and Direk M., 2006, Performance evaluation of an integrated automotive air conditioning and heat pump system, Energy Conversion of Management, 47(5), 545–559.
  8. Hoşöz M., Direk M., Yiğit K.S., Çanakçı M., Türkcan A., Alptekin E. and Şanlı A., 2015, Performance evaluation of an R134a automotive heat pump system for various heat sources in comparison with baseline heating system, Applied Thermal Engineering, 78, 419–427.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Makine Mühendisliği

Bölüm

Araştırma Makalesi

Yazarlar

Mehmet Direk Bu kişi benim
Türkiye

Fikret Yüksel Bu kişi benim
Andorra

Yayımlanma Tarihi

30 Nisan 2019

Gönderilme Tarihi

13 Eylül 2018

Kabul Tarihi

23 Ocak 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 39 Sayı: 1

Kaynak Göster

APA
Direk, M., & Yüksel, F. (2019). COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A. Isı Bilimi ve Tekniği Dergisi, 39(1), 31-38. https://izlik.org/JA58GM99MK
AMA
1.Direk M, Yüksel F. COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A. Isı Bilimi ve Tekniği Dergisi. 2019;39(1):31-38. https://izlik.org/JA58GM99MK
Chicago
Direk, Mehmet, ve Fikret Yüksel. 2019. “COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A”. Isı Bilimi ve Tekniği Dergisi 39 (1): 31-38. https://izlik.org/JA58GM99MK.
EndNote
Direk M, Yüksel F (01 Nisan 2019) COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A. Isı Bilimi ve Tekniği Dergisi 39 1 31–38.
IEEE
[1]M. Direk ve F. Yüksel, “COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A”, Isı Bilimi ve Tekniği Dergisi, c. 39, sy 1, ss. 31–38, Nis. 2019, [çevrimiçi]. Erişim adresi: https://izlik.org/JA58GM99MK
ISNAD
Direk, Mehmet - Yüksel, Fikret. “COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A”. Isı Bilimi ve Tekniği Dergisi 39/1 (01 Nisan 2019): 31-38. https://izlik.org/JA58GM99MK.
JAMA
1.Direk M, Yüksel F. COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A. Isı Bilimi ve Tekniği Dergisi. 2019;39:31–38.
MLA
Direk, Mehmet, ve Fikret Yüksel. “COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A”. Isı Bilimi ve Tekniği Dergisi, c. 39, sy 1, Nisan 2019, ss. 31-38, https://izlik.org/JA58GM99MK.
Vancouver
1.Mehmet Direk, Fikret Yüksel. COMPARATIVE EXPERIMENTAL EVALUATION ON HEATING PERFORMANCE OF A MOBILE AIR CONDITIONING SYSTEM USING R134A, R1234ZE(E), R152A and R444A. Isı Bilimi ve Tekniği Dergisi [Internet]. 01 Nisan 2019;39(1):31-8. Erişim adresi: https://izlik.org/JA58GM99MK