Araştırma Makalesi

EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015

Cilt: 38 Sayı: 1 30 Nisan 2018
  • Adem Güler
  • Mehmet Seyhan
  • Yahya Akansu
PDF İndir
TR EN

EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015

Öz

Effects of DBD plasma actuator driven by six different type modulated signals on flow around NACA 0015 airfoil are experimentally investigated for lift augmentation. One actuator attached to the upside of the airfoil at x/c = 0.1 is used. Force measurement and smoke wire flow visualization are performed in a low speed wind tunnel. For Re= 3.6x104, the actuator is driven with six different signal modulations among which frequency modulation, amplitude modulation, excitation frequency and duty cycle at α = 10°. SM4 including amplitude modulation is indicated to have better performance than the other signal modulations. Signal modulations provide energy savings while generating plasma to increase the lift coefficient. The obtained results indicate that as the dimensionless excitation frequency (F+) is 1 at low duty cycle, a better lift coefficient is obtained in comparison with the other F+ values. For Re= 3x104, the lift coefficient is proportionally increased with driving voltage and frequency due to increasing induced flow at α = 10°. Flow visualization results showed that the separated shear layer at the leading edge gets closer to the (suction) surface of the airfoil by increasing the driving voltage from 6 kVpp to 8 kVpp which confirms the driving voltage effect.

Anahtar Kelimeler

Kaynakça

  1. Akansu, Y. E., Bayindirli, C. and Seyhan, M., 2016, The Improvement of Drag Force on a Truck Traıler Vehıcle By Passıve Flow Control Methods, Isı Bılımı ve Tekniği Dergisi-Journal Of Thermal Science And Technology, 36(1), 133–141.
  2. Akansu, Y. E., Karakaya, F. and Şanlısoy, A., 2013, Active Control of Flow around NACA 0015 Airfoil by Using DBD Plasma Actuator., EPJ Web of Conferences, 45, 1008.
  3. Akansu, Y. E., Sarioglu, M. and Yavuz, T., 2004, Flow around a Rotatable Circular Cylinder-Plate Body at Subcritical Reynolds Numbers, AIAA Journal, 42(6), 1073–1080.
  4. Akbıyık, H., Akansu, Y. E. and Yavuz, H., 2017, Active Control of Flow around a Circular Cylinder By Using İntermittent DBD Plasma Actuators, Flow Measurement and Instrumentation, 53, 215–220.
  5. Asada, K., Ninomiya, Y., Oyama, A. and Fujii, K., 2009, Airfoil Flow Experiment on the Duty Cycle of DBD Plasma Actuator, 47th AIAA Aerospace Sciences Meeting including The New Horizons Forum and Aerospace Exposition.
  6. Benard, N. and Moreau, E., 2011, On the Vortex Dynamic of Airflow Reattachment Forced by a Single Non-thermal Plasma Discharge Actuator. Flow, Turbulence and Combustion, 87(1), 1–31.
  7. Benard, N. and Moreau, E., 2013, Response of a Circular Cylinder Wake to a Symmetric Actuation By Non-Thermal Plasma Discharges, Experiments in Fluids, 54(2), 1467.
  8. Benard, N. and Moreau, E., 2014, Electrical and Mechanical Characteristics of Surface AC Dielectric Barrier Discharge Plasma Actuators Applied to Airflow Control, Experiments in Fluids, 55(11), 1846. Coleman, H. W. and Steele, W. G., 2009, Experimentation, Validation, and Uncertainty Analysis for Engineers, John Wiley & Sons.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Makine Mühendisliği

Bölüm

Araştırma Makalesi

Yazarlar

Adem Güler Bu kişi benim
Andorra

Mehmet Seyhan Bu kişi benim
Türkiye

Yahya Akansu Bu kişi benim
Türkiye

Yayımlanma Tarihi

30 Nisan 2018

Gönderilme Tarihi

26 Eylül 2017

Kabul Tarihi

20 Nisan 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 38 Sayı: 1

Kaynak Göster

APA
Güler, A., Seyhan, M., & Akansu, Y. (2018). EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015. Isı Bilimi ve Tekniği Dergisi, 38(1), 95-105. https://izlik.org/JA63LG36ZS
AMA
1.Güler A, Seyhan M, Akansu Y. EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015. Isı Bilimi ve Tekniği Dergisi. 2018;38(1):95-105. https://izlik.org/JA63LG36ZS
Chicago
Güler, Adem, Mehmet Seyhan, ve Yahya Akansu. 2018. “EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015”. Isı Bilimi ve Tekniği Dergisi 38 (1): 95-105. https://izlik.org/JA63LG36ZS.
EndNote
Güler A, Seyhan M, Akansu Y (01 Nisan 2018) EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015. Isı Bilimi ve Tekniği Dergisi 38 1 95–105.
IEEE
[1]A. Güler, M. Seyhan, ve Y. Akansu, “EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015”, Isı Bilimi ve Tekniği Dergisi, c. 38, sy 1, ss. 95–105, Nis. 2018, [çevrimiçi]. Erişim adresi: https://izlik.org/JA63LG36ZS
ISNAD
Güler, Adem - Seyhan, Mehmet - Akansu, Yahya. “EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015”. Isı Bilimi ve Tekniği Dergisi 38/1 (01 Nisan 2018): 95-105. https://izlik.org/JA63LG36ZS.
JAMA
1.Güler A, Seyhan M, Akansu Y. EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015. Isı Bilimi ve Tekniği Dergisi. 2018;38:95–105.
MLA
Güler, Adem, vd. “EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015”. Isı Bilimi ve Tekniği Dergisi, c. 38, sy 1, Nisan 2018, ss. 95-105, https://izlik.org/JA63LG36ZS.
Vancouver
1.Adem Güler, Mehmet Seyhan, Yahya Akansu. EFFECT OF SIGNAL MODULATION OF DBD PLASMA ACTUATOR ON FLOW CONTROL AROUND NACA 0015. Isı Bilimi ve Tekniği Dergisi [Internet]. 01 Nisan 2018;38(1):95-105. Erişim adresi: https://izlik.org/JA63LG36ZS