TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY

Cilt: 6 Sayı: 1 2 Ocak 2012
  • Mohiuddin Ahmad
  • Mostafa Zaman Chowdhury
  • Md. Jahangir Alam
PDF İndir
EN

TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY

Öz

Tissue-motion is an important physical parameter that can be considered in discussing the strength of artery pulsation of newborn baby for pediatrics diagnosis. In this paper, we have used optical flow technique to determine the tissue-motion velocity quantitatively in cranial ultrasonogram of newborn baby. We have estimated the tissue-motion by using gradient-based optical flow method and then the time variant tissue motion velocities are analyzed by using Fourier transform. Strong pulsation is observed in the harmonic frequency of tissue-motion that has a relation to the heartbeat frequency of a newborn baby.

Anahtar Kelimeler

Kaynakça

  1. Ahmad, M., M. S. Yusuf, M. Z. Chowdhury, and M. Yamada, “Global optimization of optical flow technique on the computation of tissue-motion in neonatal cranial ultrasonogram,” Electronic Engineering, Istanbul university, vol. , no. 1, pp. 1007-1016, 2004.
  2. Kearney, J. K. , W. B. Thompson, and D. L. Analysis of Gradient-Based Methods with Local Optimization,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 9, pp. 244, March 1987.
  3. Fukazawa, M., H. Kubo, Y. Kitsunezuka, and M. Yamada, 1999, “Motion analysis of artery pulsation in neonatal cranial ultrasonogram,” SPIE, vol. 3661.
  4. Kitsunezuka, Y., and H. Nakamura, “Syonika-Rinsyo,” no. 38, pp. 297-308 [in Japanese], 1985.
  5. Press, W. H., Saul A. Teukolsky, William T. Vetterling and Brian P. Flannery, “Numerical Recipes in C: The art of Scientific Computing”, Second Edition, Cambridge University press. ultrasonogram,” Jpn. J. Appl. Physics. 37, pp. 1178, 1998.
  6. Yamada, M., M. Fukuzawa, Y. Kitsunezuka, J. Kishida, N. Nakamori, H. Kanamori, T. Sakurai and S. Kodama, “Pulsation detection from noisy ultrasound echo moving images of newborn baby head using Fourier transform,” Jpn. J. Appl. Phys., Vol. 34, p. 2854-2856, 1995.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Mohiuddin Ahmad Bu kişi benim

Mostafa Zaman Chowdhury Bu kişi benim

Md. Jahangir Alam Bu kişi benim

Yayımlanma Tarihi

2 Ocak 2012

Gönderilme Tarihi

2 Ocak 2012

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2006 Cilt: 6 Sayı: 1

Kaynak Göster

APA
Ahmad, M., Chowdhury, M. Z., & Alam, M. J. (2012). TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering, 6(1), 53-59. https://izlik.org/JA88JH75KY
AMA
1.Ahmad M, Chowdhury MZ, Alam MJ. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering. 2012;6(1):53-59. https://izlik.org/JA88JH75KY
Chicago
Ahmad, Mohiuddin, Mostafa Zaman Chowdhury, ve Md. Jahangir Alam. 2012. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering 6 (1): 53-59. https://izlik.org/JA88JH75KY.
EndNote
Ahmad M, Chowdhury MZ, Alam MJ (01 Ocak 2012) TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering 6 1 53–59.
IEEE
[1]M. Ahmad, M. Z. Chowdhury, ve M. J. Alam, “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”, IU-Journal of Electrical & Electronics Engineering, c. 6, sy 1, ss. 53–59, Oca. 2012, [çevrimiçi]. Erişim adresi: https://izlik.org/JA88JH75KY
ISNAD
Ahmad, Mohiuddin - Chowdhury, Mostafa Zaman - Alam, Md. Jahangir. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering 6/1 (01 Ocak 2012): 53-59. https://izlik.org/JA88JH75KY.
JAMA
1.Ahmad M, Chowdhury MZ, Alam MJ. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering. 2012;6:53–59.
MLA
Ahmad, Mohiuddin, vd. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering, c. 6, sy 1, Ocak 2012, ss. 53-59, https://izlik.org/JA88JH75KY.
Vancouver
1.Mohiuddin Ahmad, Mostafa Zaman Chowdhury, Md. Jahangir Alam. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering [Internet]. 01 Ocak 2012;6(1):53-9. Erişim adresi: https://izlik.org/JA88JH75KY