ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION
Öz
This paper presents a new setting-free approach to synchronization of two-end current and voltage unsynchronized measurements. Authors propose new non-iterative algorithm processing three-phase currents and voltages measured under normal steady state load condition of overhead line. Using such synchronization the line parameters can be estimated and then precise fault location can be performed. The presented algorithm has been tested with ATP-EMTP software by generating great number of simulations with various sets of line parameters proving its usefulness for overhead lines up to 200km length.
Anahtar Kelimeler
Kaynakça
- M.M. Saha, J. Izykowski, E. Rosolowski, “Fault location on power networks”, Springer-Verlag London, Series: Power Systems, 2010.
- M. Kezunovic, J. Mrkic, B. Perunicic, "An accurate fault location algorithm using synchronized sampling", Electric Power Systems Research Journal, Vol. 29, No. 3, pp. 161– 169, 1994.
- A.L. Dalcastagne, S.N. Filho, H.H. Zurn, R. Seara, "A Two-terminal fault location approach based on unsynchronized phasors", International Conference on Power System Technology, Chongging, 2006.
- J. Izykowski, R. Molag, E. Rosolowski, M.M. Saha, "Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements", IEEE Trans. on Power Delivery, Vol. 21, No. 2, pp. 627–633, 200 E.G. Silveira, C. Pereira, "Transmission line fault location using two-terminal data without time synchronization", IEEE Trans. on Power Delivery, Vol. 22, No. 1, pp. 498– 499, 2007.
- F. Chunju, D. Xiujua, L. Shengfang, Y. Weiyong, "An adaptive fault location technique based on PMU for transmission line", Power Engineering Society General Meeting, Tampa, USA, 2007.
- Z.M. Radojevic, B. Kovacevic, G. Preston, V. Terzija, "New approach for fault location on transmission lines not requiring line parameters", International Conference on Power Systems Transients, Kyoto, Japan, 2009.
- Y. Liao, S. Elangovan, "Unsynchronized two-terminal transmission-line fault-location without using line parameters", IEE Proc.-Gener. Transm. Distrib., Vol. 153, No. 6, pp. 639–643, 2006.
- Y. Liao, "Algorithms for power system fault location and line parameter estimation", 39th Southeastern Symposium on System Theory, Macon, GA, USA, pp. 207–211, 2007.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
2 Eylül 2013
Gönderilme Tarihi
2 Eylül 2013
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2013 Cilt: 13 Sayı: 1