EN
Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition
Öz
Modern power systems are at risks of voltage instability problems due to highly stressed operating conditions caused by increased load demand. This paper proposes a hybrid Differential Evolution (DE)/Particle Swarm Optimization (PSO) algorithm based optimal reactive power flow control task incorporating only one type of FACTS device. DE is efficient in exploration through the search space of the problem but not so good in exploitation while PSO is highly efficient in exploitation of the solutions. The hybrid algorithm combines the features of both DE and PSO and is capable of finding the global best solution without easily trapping in to the local minima. Optimal settings of control variables of generator voltages, transformer tap settings and location and parameter setting of TCSC is considered for optimal solution for reactive power flow control and the resultant reactive power reserves. The effectiveness of the proposed work is tested on IEEE-30 Bus test system.
Anahtar Kelimeler
Kaynakça
- C. W. Taylor, Power System Voltage Stability. New York: M cGraw-Hill, 1994P.
- Kessel and H. Glavitsch, "Estimating the Voltage Stability of Power System," IEEE Transactions on Power Delivery, Vol. PWRD-1, No. 3, pp. 346- 354, July 1986.
- H. Wan, J. D. M c Calley and V. Vittal, “Risk Based Voltage Security Assessment”, IEEE Transaction on Power Systems, Vol. 15, No. 4, Nov. 2000, pp. 1247 – 1254.
- Feng Dong, et al, “Improving Voltage Stability by Reactive Power Reserve Management” IEEE Transactions on Power Systems, Vol. 20, N0.1, pp.338-345, February 2005.
- T. M enezes, L. C. da Silva, and V. F. da Costa, “Dynamic VAR Sources Scheduling for Improving Voltage Stability Margin,” IEEE Transaction on Power Systems, Vol. 18, No. 2, pp. 969–971, M ay 2003.
- S. Granville, “Optimal Reactive Dispatch Through Interior Point Methods,” IEEE Transactions on Power Systems, Vol. 9, No. 1, pp. 136–146, Feb. 1994.
- E. Vaahedi, Y. M ansour, C. Fuchs, S. Granville, M . D. L. Latore, and H. Hamadanizadeh, “Dynamic Security Constrained Optimal Power Flow/var Planning,” IEEE Transactions on Power Systems, Vol. 16, No. 1, pp. 38–43, Feb. 2001.
- K. Price, R. Storn, “Differential evolution – A Simple and Optimization over Continuous Spaces, Technical Report, International Computer Science Institute”, Berkley, 1995. Scheme for Global [9] J. Kennedy, R. Eberhart, optimization”, Proceedings of the IEEE International Conference on Neural Networks, pp. 1942- 1948 1995. "Particle swarm
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
2 Eylül 2013
Gönderilme Tarihi
2 Eylül 2013
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2012 Cilt: 12 Sayı: 1
APA
Sakthıvel, S., & Mary, D. (2013). Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition. IU-Journal of Electrical & Electronics Engineering, 12(1), 1419-1430. https://izlik.org/JA94CJ35MM
AMA
1.Sakthıvel S, Mary D. Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition. IU-Journal of Electrical & Electronics Engineering. 2013;12(1):1419-1430. https://izlik.org/JA94CJ35MM
Chicago
Sakthıvel, S, ve D Mary. 2013. “Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition”. IU-Journal of Electrical & Electronics Engineering 12 (1): 1419-30. https://izlik.org/JA94CJ35MM.
EndNote
Sakthıvel S, Mary D (01 Eylül 2013) Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition. IU-Journal of Electrical & Electronics Engineering 12 1 1419–1430.
IEEE
[1]S. Sakthıvel ve D. Mary, “Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition”, IU-Journal of Electrical & Electronics Engineering, c. 12, sy 1, ss. 1419–1430, Eyl. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA94CJ35MM
ISNAD
Sakthıvel, S - Mary, D. “Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition”. IU-Journal of Electrical & Electronics Engineering 12/1 (01 Eylül 2013): 1419-1430. https://izlik.org/JA94CJ35MM.
JAMA
1.Sakthıvel S, Mary D. Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition. IU-Journal of Electrical & Electronics Engineering. 2013;12:1419–1430.
MLA
Sakthıvel, S, ve D Mary. “Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition”. IU-Journal of Electrical & Electronics Engineering, c. 12, sy 1, Eylül 2013, ss. 1419-30, https://izlik.org/JA94CJ35MM.
Vancouver
1.S Sakthıvel, D Mary. Reactive Power Optimization for Voltage Stability Limit Improvement Incorporating TCSC Device through DE/PSO under Contingency Condition. IU-Journal of Electrical & Electronics Engineering [Internet]. 01 Eylül 2013;12(1):1419-30. Erişim adresi: https://izlik.org/JA94CJ35MM