A new second harmonically pumped SiGe mixer circuit topology is proposed. The proposed circuit is developed to be employed in integrated circuit receivers which use Zero-IF mixers. The proposed circuit topology is analyzed to determine the appropriate operating conditions. It has a unique mechanism to prevent the local oscillator (LO) leakage to radio frequency (RF) signal which results in DC offset voltage at the output. Detailed analysis results are given regarding the biasing dependence of the conversion voltage gain and the linearity of the produced pumping current. The results are also verified by simulation results. Simulation results show that the DC offset voltage at the output stays more than 80 dB below the intermediate frequency (IF) signal.

Yıl 2016, Cilt: 16 Sayı: 1, 1965 - 1970, 27.04.2016
https://izlik.org/JA78WZ53WJ

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Araştırma Makalesi
Yazarlar

Umut Guvenc

Osman Palamutcuogullari

Siddik Yarman

Yayımlanma Tarihi 27 Nisan 2016
IZ https://izlik.org/JA78WZ53WJ
Yayımlandığı Sayı Yıl 2016 Cilt: 16 Sayı: 1

Kaynak Göster

APA Guvenc, U., Palamutcuogullari, O., & Yarman, S. (2016). Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation. IU-Journal of Electrical & Electronics Engineering, 16(1), 1965-1970. https://izlik.org/JA78WZ53WJ
AMA 1.Guvenc U, Palamutcuogullari O, Yarman S. Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation. IU-Journal of Electrical & Electronics Engineering. 2016;16(1):1965-1970. https://izlik.org/JA78WZ53WJ
Chicago Guvenc, Umut, Osman Palamutcuogullari, ve Siddik Yarman. 2016. “Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation”. IU-Journal of Electrical & Electronics Engineering 16 (1): 1965-70. https://izlik.org/JA78WZ53WJ.
EndNote Guvenc U, Palamutcuogullari O, Yarman S (01 Nisan 2016) Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation. IU-Journal of Electrical & Electronics Engineering 16 1 1965–1970.
IEEE [1]U. Guvenc, O. Palamutcuogullari, ve S. Yarman, “Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation”, IU-Journal of Electrical & Electronics Engineering, c. 16, sy 1, ss. 1965–1970, Nis. 2016, [çevrimiçi]. Erişim adresi: https://izlik.org/JA78WZ53WJ
ISNAD Guvenc, Umut - Palamutcuogullari, Osman - Yarman, Siddik. “Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation”. IU-Journal of Electrical & Electronics Engineering 16/1 (01 Nisan 2016): 1965-1970. https://izlik.org/JA78WZ53WJ.
JAMA 1.Guvenc U, Palamutcuogullari O, Yarman S. Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation. IU-Journal of Electrical & Electronics Engineering. 2016;16:1965–1970.
MLA Guvenc, Umut, vd. “Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation”. IU-Journal of Electrical & Electronics Engineering, c. 16, sy 1, Nisan 2016, ss. 1965-70, https://izlik.org/JA78WZ53WJ.
Vancouver 1.Guvenc U, Palamutcuogullari O, Yarman S. Zero-IF Second Harmonic SiGe Mixer with DC Offset Cancellation. IU-Journal of Electrical & Electronics Engineering [Internet]. 01 Nisan 2016;16(1):1965-70. Erişim adresi: https://izlik.org/JA78WZ53WJ