A Fully Automatic Novel Method to Determine QT Interval Based on Continuous Wavelet Transform
Öz
Nowadays, automatic recognition algorithm
is being frequently utilized to extract the information concerning cardiac
abnormalities. In this study, a fully automatic novel method based on the continuous
wavelet transform (CWT) was developed for QT intervals in various ECG signals.
Especially, the determination of T-wave end is the paramount problem to be
solved.The developed method was performed to find the beginning of QRS
complexes and the end of T-wave. The proposed algorithm was tested on
MIT-BIH-NSR database given by QT database, then, it yielded the scores 15.17
milliseconds and root-mean-square error of 17.19 milliseconds at silver
standard, 19.22 milliseconds and 20.22 milliseconds at gold standard,
respectively. In conclusion, the proposed algorithm is a fully automatic method
to attain a high performance in the calculation of QT intervals at various ECG
signals.
Anahtar Kelimeler
Kaynakça
- Goldberg, R. J., Bengtson, J., Chen, Z., Anderson, K. M., Locati, E., & Levy, D.,"Duration of the QT interval and total and cardiovascular mortality in healthy persons (The Framingham Heart Study experience)".,The American journal of cardiology, 67(1), 55-58.,1991
- Zhang, Q., Manriquez, A. I., Médigue, C., Papelier, Y., & Sorine, M.,“An algorithm for robust and efficient location of T-wave ends in electrocardiograms”,IEEE Transactions on Biomedical Engineering, 53(12), 2544-2552,2006.
- Goldenberg, I. L. A. N., Moss, A. J., & Zareba, W. QT interval: how to measure it and what is" normal". Journal of cardiovascular electrophysiology, 17(3), 333-336, (2006).
- Helfenbein, E. D., Zhou, S. H., Lindauer, J. M., Field, D. Q., Gregg, R. E., Wang, J. J., ... & Michaud, F. P. An algorithm for continuous real-time QT interval monitoring. Journal of electrocardiology, 39(4), S123-S127, (2006).
- Murray, A., McLaughlin, N. B., Bourke, J. P., Doig, J. C., Furniss, S. S., & Campbell, R. W.,“Errors in manual measurement of QT intervals”,British Heart Journal, 71(4), 386-390, (1994).
- McLaughlin, N. B., Campbell, R. W. F., & Murray, A.,“Accuracy of automatic QT measurement techniques”. Computers in Cardiology, Proceedings. 863-866. IEEE, 1993.
- Hayn, D., Kollmann, A., & Schreier, G.,“Automated QT interval measurement from multilead ECG signals”,Computers in Cardiology, 381-384, IEEE, 2006.
- Clifford, G. D., & Villarroel, M. C.,“Model-based determination of QT intervals”,Computers in Cardiology, 357-360, IEEE, 2006.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Konferans Bildirisi
Yazarlar
Cüneyt Yılmaz
YILDIZ TEKNIK UNIV
Türkiye
Mehmet İşcan
YILDIZ TEKNIK UNIV
Türkiye
Abdurrahman Yılmaz
YILDIZ TEKNIK UNIV
Türkiye
Yayımlanma Tarihi
27 Mart 2017
Gönderilme Tarihi
31 Ocak 2017
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2017 Cilt: 17 Sayı: 1