Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2013, Cilt: 13 Sayı: 1, 1569 - 1574, 02.09.2013

Öz

Kaynakça

  • M.M. Saha, J. Izykowski, E. Rosolowski, “Fault location on power networks”, Springer-Verlag London, Series: Power Systems, 2010.
  • M. Kezunovic, J. Mrkic, B. Perunicic, "An accurate fault location algorithm using synchronized sampling", Electric Power Systems Research Journal, Vol. 29, No. 3, pp. 161– 169, 1994.
  • A.L. Dalcastagne, S.N. Filho, H.H. Zurn, R. Seara, "A Two-terminal fault location approach based on unsynchronized phasors", International Conference on Power System Technology, Chongging, 2006.
  • J. Izykowski, R. Molag, E. Rosolowski, M.M. Saha, "Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements", IEEE Trans. on Power Delivery, Vol. 21, No. 2, pp. 627–633, 200 E.G. Silveira, C. Pereira, "Transmission line fault location using two-terminal data without time synchronization", IEEE Trans. on Power Delivery, Vol. 22, No. 1, pp. 498– 499, 2007.
  • F. Chunju, D. Xiujua, L. Shengfang, Y. Weiyong, "An adaptive fault location technique based on PMU for transmission line", Power Engineering Society General Meeting, Tampa, USA, 2007.
  • Z.M. Radojevic, B. Kovacevic, G. Preston, V. Terzija, "New approach for fault location on transmission lines not requiring line parameters", International Conference on Power Systems Transients, Kyoto, Japan, 2009.
  • Y. Liao, S. Elangovan, "Unsynchronized two-terminal transmission-line fault-location without using line parameters", IEE Proc.-Gener. Transm. Distrib., Vol. 153, No. 6, pp. 639–643, 2006.
  • Y. Liao, "Algorithms for power system fault location and line parameter estimation", 39th Southeastern Symposium on System Theory, Macon, GA, USA, pp. 207–211, 2007.
  • Y. Liao, "Algorithms for fault location and line parameter estimation utilizing voltage and current data during the fault", 40th Southeastern Symposium on System Theory, New Orleans, LA, USA, pp. 183–187, 2008.
  • Y. Liao, N. Kang, "Fault-location algorithms without utilizing line parameters based on the distributed parameter line model", IEEE Trans. on Power Delivery, Vol. 24, No. 2, pp. 579–584, 2009.
  • E. Price, "Practical considerations for implementing wide area monitoring, protection and control", 59th Annual Conference: Protective Relay Engineers, Texas, 2006.
  • R.E. Wilson, G.A. Zevenbergen, D.L. Mah, A.J. Murphy, "Calculation of transmission line parameters from synchronized measurements", Electric Power Components and Systems, Vol. 33, No. 10, pp. 1269–1278, 2005.
  • Z. Hum, Y. Chen, "New method of live line measuring the inductance parameters of transmission line based on GPS technology", IEEE Trans. on Power Delivery, Vol. 23, No. 3, pp. 1288–1295, 2008.
  • D. Shi, D.J. Tylavsky, N. Logic, K.M. Koellner, "Identification of short transmission-line parameters from synchrophasor measurements", 40th North American Power Symposium, Calgary, Canada, 2008.
  • Z. Hu, J. Fan, M. Chen, Z. Xu, "New method of live line measuring the parameters of t-connection transmission lines with mutual inductance", Power & Energy Society General Meeting, Calgary, Canada, 2009.
  • H. Khorashadi-Zadeh, H.Z. Li, "A novel PMU-based transmission line protection scheme design", 39th North American Power Symposium, Las Cruces, New Mexico, USA, 2007.
  • R. Schulze, P. Schegner, R. Zivanovic, "Parameter identification of unsymmetrical transmission lines using fault records obtained from protective relays", IEEE Trans. on Power Delivery, Vol. 26, No. 2, pp. 1265–1272, April 20
  • P.M. Silveira, F.O. Passos, A. Assuncao, "Optimized estimation of untransposed transmission lines parameters using phasor measurement units and its application to fault location", International Conference on Advanced Power System Automation and Protection – APAP, Jeju, Vol. 1, pp. 1–6, 2009. H. Dommel, ElectroMagnetic Transients Program, Bonneville Power Administration, Portland, OR, 1986.
  • Biographies : Pawel Dawıdowskı received his M.Sc. in Electrical Eng. from the Wroclaw University of Technology (WrUT) in 2009. Then for two years he was Ph.D. student at the Faculty of Electrical Engineering of this University. Presently he is with ABB Corporate Research Center in Krakow, Poland. Fault location and simulation of power system transients are in the scope of his research interests. Jan Izykowski received his M.Sc., Ph.D. and D.Sc. degrees from the Faculty of Electrical Engineering of Wroclaw University of Technology (WrUT) in 1973, 1976 and in 2001, respectively. In 2009 he was granted with a scientific title of a professor by the President of the Republic of Poland. Since 1973 he has been with Institute of Electrical Power Engineering of the WrUT where he is presently a director of this Institute. His research interests are in power system transients simulation, power system protection and control, and fault location. He is a holder of 25 international patents and authored more than 200 technical papers. Ahmet Nayir was graduated from Yildiz Technical University (İstanbul, Turkey) with honor diploma in the field of Electrical Engineering (B.Sc. degrees) in 1991. He received the Ph.D. degree in Physical Institute of Azerbaijan Science Academy in 2002. Nayir has been at Fatih University (Istanbul, Turkey), where he is currently an assistance Professor. From September 2009 to May 2010 Ahmet Nayir worked as visiting scholar in Electrical Engineering Technology Department of Industrial Technology University of Northern Iowa. From May to October 2010 Ahmet Nayir worked as visiting scholar in Wroclaw University of Technology Institute of Electrical Power Engineering, Wroclaw- Poland. His research interests are focused on energy generation, control, analysis and applications in power systems.

ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION

Yıl 2013, Cilt: 13 Sayı: 1, 1569 - 1574, 02.09.2013

Öz

This paper presents a new setting-free approach to synchronization of two-end current and voltage unsynchronized measurements. Authors propose new non-iterative algorithm processing three-phase currents and voltages measured under normal steady state load condition of overhead line. Using such synchronization the line parameters can be estimated and then precise fault location can be performed. The presented algorithm has been tested with ATP-EMTP software by generating great number of simulations with various sets of line parameters proving its usefulness for overhead lines up to 200km length.

Kaynakça

  • M.M. Saha, J. Izykowski, E. Rosolowski, “Fault location on power networks”, Springer-Verlag London, Series: Power Systems, 2010.
  • M. Kezunovic, J. Mrkic, B. Perunicic, "An accurate fault location algorithm using synchronized sampling", Electric Power Systems Research Journal, Vol. 29, No. 3, pp. 161– 169, 1994.
  • A.L. Dalcastagne, S.N. Filho, H.H. Zurn, R. Seara, "A Two-terminal fault location approach based on unsynchronized phasors", International Conference on Power System Technology, Chongging, 2006.
  • J. Izykowski, R. Molag, E. Rosolowski, M.M. Saha, "Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements", IEEE Trans. on Power Delivery, Vol. 21, No. 2, pp. 627–633, 200 E.G. Silveira, C. Pereira, "Transmission line fault location using two-terminal data without time synchronization", IEEE Trans. on Power Delivery, Vol. 22, No. 1, pp. 498– 499, 2007.
  • F. Chunju, D. Xiujua, L. Shengfang, Y. Weiyong, "An adaptive fault location technique based on PMU for transmission line", Power Engineering Society General Meeting, Tampa, USA, 2007.
  • Z.M. Radojevic, B. Kovacevic, G. Preston, V. Terzija, "New approach for fault location on transmission lines not requiring line parameters", International Conference on Power Systems Transients, Kyoto, Japan, 2009.
  • Y. Liao, S. Elangovan, "Unsynchronized two-terminal transmission-line fault-location without using line parameters", IEE Proc.-Gener. Transm. Distrib., Vol. 153, No. 6, pp. 639–643, 2006.
  • Y. Liao, "Algorithms for power system fault location and line parameter estimation", 39th Southeastern Symposium on System Theory, Macon, GA, USA, pp. 207–211, 2007.
  • Y. Liao, "Algorithms for fault location and line parameter estimation utilizing voltage and current data during the fault", 40th Southeastern Symposium on System Theory, New Orleans, LA, USA, pp. 183–187, 2008.
  • Y. Liao, N. Kang, "Fault-location algorithms without utilizing line parameters based on the distributed parameter line model", IEEE Trans. on Power Delivery, Vol. 24, No. 2, pp. 579–584, 2009.
  • E. Price, "Practical considerations for implementing wide area monitoring, protection and control", 59th Annual Conference: Protective Relay Engineers, Texas, 2006.
  • R.E. Wilson, G.A. Zevenbergen, D.L. Mah, A.J. Murphy, "Calculation of transmission line parameters from synchronized measurements", Electric Power Components and Systems, Vol. 33, No. 10, pp. 1269–1278, 2005.
  • Z. Hum, Y. Chen, "New method of live line measuring the inductance parameters of transmission line based on GPS technology", IEEE Trans. on Power Delivery, Vol. 23, No. 3, pp. 1288–1295, 2008.
  • D. Shi, D.J. Tylavsky, N. Logic, K.M. Koellner, "Identification of short transmission-line parameters from synchrophasor measurements", 40th North American Power Symposium, Calgary, Canada, 2008.
  • Z. Hu, J. Fan, M. Chen, Z. Xu, "New method of live line measuring the parameters of t-connection transmission lines with mutual inductance", Power & Energy Society General Meeting, Calgary, Canada, 2009.
  • H. Khorashadi-Zadeh, H.Z. Li, "A novel PMU-based transmission line protection scheme design", 39th North American Power Symposium, Las Cruces, New Mexico, USA, 2007.
  • R. Schulze, P. Schegner, R. Zivanovic, "Parameter identification of unsymmetrical transmission lines using fault records obtained from protective relays", IEEE Trans. on Power Delivery, Vol. 26, No. 2, pp. 1265–1272, April 20
  • P.M. Silveira, F.O. Passos, A. Assuncao, "Optimized estimation of untransposed transmission lines parameters using phasor measurement units and its application to fault location", International Conference on Advanced Power System Automation and Protection – APAP, Jeju, Vol. 1, pp. 1–6, 2009. H. Dommel, ElectroMagnetic Transients Program, Bonneville Power Administration, Portland, OR, 1986.
  • Biographies : Pawel Dawıdowskı received his M.Sc. in Electrical Eng. from the Wroclaw University of Technology (WrUT) in 2009. Then for two years he was Ph.D. student at the Faculty of Electrical Engineering of this University. Presently he is with ABB Corporate Research Center in Krakow, Poland. Fault location and simulation of power system transients are in the scope of his research interests. Jan Izykowski received his M.Sc., Ph.D. and D.Sc. degrees from the Faculty of Electrical Engineering of Wroclaw University of Technology (WrUT) in 1973, 1976 and in 2001, respectively. In 2009 he was granted with a scientific title of a professor by the President of the Republic of Poland. Since 1973 he has been with Institute of Electrical Power Engineering of the WrUT where he is presently a director of this Institute. His research interests are in power system transients simulation, power system protection and control, and fault location. He is a holder of 25 international patents and authored more than 200 technical papers. Ahmet Nayir was graduated from Yildiz Technical University (İstanbul, Turkey) with honor diploma in the field of Electrical Engineering (B.Sc. degrees) in 1991. He received the Ph.D. degree in Physical Institute of Azerbaijan Science Academy in 2002. Nayir has been at Fatih University (Istanbul, Turkey), where he is currently an assistance Professor. From September 2009 to May 2010 Ahmet Nayir worked as visiting scholar in Electrical Engineering Technology Department of Industrial Technology University of Northern Iowa. From May to October 2010 Ahmet Nayir worked as visiting scholar in Wroclaw University of Technology Institute of Electrical Power Engineering, Wroclaw- Poland. His research interests are focused on energy generation, control, analysis and applications in power systems.
Toplam 19 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Makaleler
Yazarlar

Pawel Dawıdowskı

Jan Izykowskı Bu kişi benim

Ahmet Nayır Bu kişi benim

Yayımlanma Tarihi 2 Eylül 2013
Yayımlandığı Sayı Yıl 2013 Cilt: 13 Sayı: 1

Kaynak Göster

APA Dawıdowskı, P., Izykowskı, J., & Nayır, A. (2013). ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION. IU-Journal of Electrical & Electronics Engineering, 13(1), 1569-1574.
AMA Dawıdowskı P, Izykowskı J, Nayır A. ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION. IU-Journal of Electrical & Electronics Engineering. Eylül 2013;13(1):1569-1574.
Chicago Dawıdowskı, Pawel, Jan Izykowskı, ve Ahmet Nayır. “ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION”. IU-Journal of Electrical & Electronics Engineering 13, sy. 1 (Eylül 2013): 1569-74.
EndNote Dawıdowskı P, Izykowskı J, Nayır A (01 Eylül 2013) ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION. IU-Journal of Electrical & Electronics Engineering 13 1 1569–1574.
IEEE P. Dawıdowskı, J. Izykowskı, ve A. Nayır, “ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION”, IU-Journal of Electrical & Electronics Engineering, c. 13, sy. 1, ss. 1569–1574, 2013.
ISNAD Dawıdowskı, Pawel vd. “ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION”. IU-Journal of Electrical & Electronics Engineering 13/1 (Eylül 2013), 1569-1574.
JAMA Dawıdowskı P, Izykowskı J, Nayır A. ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION. IU-Journal of Electrical & Electronics Engineering. 2013;13:1569–1574.
MLA Dawıdowskı, Pawel vd. “ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION”. IU-Journal of Electrical & Electronics Engineering, c. 13, sy. 1, 2013, ss. 1569-74.
Vancouver Dawıdowskı P, Izykowskı J, Nayır A. ANALYTICAL SYNCHRONIZATION OF TWO-END MEASUREMENTS FOR TRANSMISSION LINE PARAMETERS ESTIMATION AND FAULT LOCATION. IU-Journal of Electrical & Electronics Engineering. 2013;13(1):1569-74.