Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius

Öz

Dielectric strength is a very important parameter for cables. It can vary according to temperature and frequency. The complex electrical permittivity of the Cross-linked polyethylene (XLPE) and Copper Polyester/Mylar band layers of a cable determine the maximum electric field created inside the cable operating at sinusoidal voltage. The value of this electric field should be less than the dielectric strength of the materials used. The electrical characteristics of XLPE and Copper Polyester tape depend on frequency and temperature. In a power cable, the temperature depends on the radial position, which makes it difficult to calculate the cable’s electric field. In this study, it was shown how to calculate the electric field of the cable by using XLPE and Copper Polyester band data taken from the literature and numerical integration. It was found that the calculated value is less than the Dielectric strength value of XLPE material. It has been shown how the electric field of the power cable under investigation changes according to frequency and temperature.

Anahtar Kelimeler

Kaynakça

  1. [1] Moore, G.F., "Electric cables handbook", Third Edition, Blackwell Science Ltd (1997).
  2. [2] Gouda, O.E., Matter, Z., "Effect of the temperature rise on the XLPE dielectric properties", IEEE Proceedings of the 35th Midwest Symposium on Circuits and Systems 1 (1992) : 95-98.
  3. [3] Li, C., Chu, Z., Zhang, L., Zhang, J., Tao, J., "Insulation aging diagnosis and defect location of crosslinked polyethylene cable in the distribution network based on radio frequency identification", Materials Express 13(10) (2023) : 1772-1781.
  4. [4] Karhan, M., Ugur, M., "XLPE İzoleli Tek Damarlı Orta Gerilim Kablolarında Elektrik Alanının Sulu Ağaçlanmaya Etkisinin İncelenmesi", Göç Sistemleri Konferansı Proceedings (2016).
  5. [5] Karhan, M., Çakir, M., Arslan, Ö., Issi, F., Eyüpoğlu, V., "XLPE dielektrik malzemelerde elektrik alanının temas açısına ve damlacık şekline etkisi", Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi 36 (2021).
  6. [6] Wagenaars, P., Wouters, P.A.A.F., Van der Wielen, P., Steennis, E.F., "Approximation of Transmission Line Parameters of Single-core and Three-core XLPE Cables", IEEE Transactions on Dielectrics and Electrical Insulation 17 (2010) : 106-115.
  7. [7] Gallot-Lavallée, O., "Dielectric Materials and Electrostatics" (2013).
  8. [8] Cooper, E., Dissado, L.A., Fothergill, J., "Application of thermoelectric aging models to polymeric insulation in cable geometry", IEEE Transactions on Dielectrics and Electrical Insulation 12 (2005) : 1-10.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Enerjisi Taşıma, Şebeke ve Sistemleri

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Ağustos 2025

Gönderilme Tarihi

13 Aralık 2023

Kabul Tarihi

19 Mayıs 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 10 Sayı: 2

Kaynak Göster

APA
Alisoy, H., Mutlu, R., Korkmaz Tan, R., & Çanta, H. (2025). Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius. Journal of Engineering Technology and Applied Sciences, 10(2), 97-113. https://doi.org/10.30931/jetas.1404278
AMA
1.Alisoy H, Mutlu R, Korkmaz Tan R, Çanta H. Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius. Journal of Engineering Technology and Applied Sciences. 2025;10(2):97-113. doi:10.30931/jetas.1404278
Chicago
Alisoy, Hafiz, Reşat Mutlu, Rabia Korkmaz Tan, ve Hakan Çanta. 2025. “Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius”. Journal of Engineering Technology and Applied Sciences 10 (2): 97-113. https://doi.org/10.30931/jetas.1404278.
EndNote
Alisoy H, Mutlu R, Korkmaz Tan R, Çanta H (01 Ağustos 2025) Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius. Journal of Engineering Technology and Applied Sciences 10 2 97–113.
IEEE
[1]H. Alisoy, R. Mutlu, R. Korkmaz Tan, ve H. Çanta, “Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius”, Journal of Engineering Technology and Applied Sciences, c. 10, sy 2, ss. 97–113, Ağu. 2025, doi: 10.30931/jetas.1404278.
ISNAD
Alisoy, Hafiz - Mutlu, Reşat - Korkmaz Tan, Rabia - Çanta, Hakan. “Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius”. Journal of Engineering Technology and Applied Sciences 10/2 (01 Ağustos 2025): 97-113. https://doi.org/10.30931/jetas.1404278.
JAMA
1.Alisoy H, Mutlu R, Korkmaz Tan R, Çanta H. Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius. Journal of Engineering Technology and Applied Sciences. 2025;10:97–113.
MLA
Alisoy, Hafiz, vd. “Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius”. Journal of Engineering Technology and Applied Sciences, c. 10, sy 2, Ağustos 2025, ss. 97-113, doi:10.30931/jetas.1404278.
Vancouver
1.Hafiz Alisoy, Reşat Mutlu, Rabia Korkmaz Tan, Hakan Çanta. Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius. Journal of Engineering Technology and Applied Sciences. 01 Ağustos 2025;10(2):97-113. doi:10.30931/jetas.1404278