EN
Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique
Öz
One of the solutions for density measurement is to make use of gamma-ray transmission technique. We studied by this technique, using by Co-60 and Cs-137. Each source, without materials in geometry, was counted and noted intensities as (I0). All materials were counted and noted intensities as (I). [I/I0] rates were calculated. Now, density of materials could be determined via using Beer-Lambert Equation. Experimental application was performed on industrial metals or metal alloys like lead&copper and steel&brass. Given densities and obtained densities were compared. Differences or deviations for lead, stell copper and brass are -5.07; 0.26; 1.11; -5.73 (Co-60) and 1.07; 3.08; -0.22; 2.34 (Cs-137) consequently. It could be said that, these differences are still in acceptable limits.
Anahtar Kelimeler
Kaynakça
- [1] Mix, P.E., “Introduction to non-destructive testing”, John Wiley, New York, (1987).
- [2] Turgay, M.E., “Density assessment of different metals and alloys by gamma-ray transmission technique via using Co-60 radioactive source”, Journal of Physical Science and Application 7(1) (2017) : 39–42.
- [3] Földiak, G., “Industrial application of radioisotopes”, Institute of Isotopes of the Hungarian Academy of Sciences, Budapest, (1986).
- [4] Buyuk, B., “Gamma attenuation behavior of some stainless and boron steels”, Acta Physica Polonica A 127(4) (2015) : 1342-1345.
- [5] Buyuk, B., Tugrul, A.B., “An investigation on gamma attenuation behaviour of titanium diboride reinforced boron carbide–silicon carbide composites”, Radiation Physics and Chemistry 97 (2014) : 354-359.
- [6] Moreira, A.C., Appoloni, C.R., Fernandes, C.P., “Gamma ray transmission technique applied to porous phase characterization of low-porosity ceramic samples”, Materials and structures 46(4) (2013) : 629-637.
- [7] Karagoz, B., et al. “Determination of Gamma Transmittance and Density Assessment for Al Doped ZnO Thin Films by Using Gamma Transmission Technique”, Defect and Diffusion Forum 312–315 (2011) : 830–835, https://doi.org/10.4028/www.scientific.net/ddf.312-315.830.
- [8] Bjoernstad, T., Stamatakis, E., “Scaling studies with gamma transmission technique”, Conference: Oil Field Chemistry, At: Geilo, Norway, (2006).
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yazarlar
Yayımlanma Tarihi
30 Nisan 2021
Gönderilme Tarihi
5 Şubat 2021
Kabul Tarihi
7 Nisan 2021
Yayımlandığı Sayı
Yıl 2021 Cilt: 6 Sayı: 1
APA
Turgay, M. E. (2021). Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique. Journal of Engineering Technology and Applied Sciences, 6(1), 37-43. https://doi.org/10.30931/jetas.891679
AMA
1.Turgay ME. Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique. Journal of Engineering Technology and Applied Sciences. 2021;6(1):37-43. doi:10.30931/jetas.891679
Chicago
Turgay, Muttalip Ergun. 2021. “Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique”. Journal of Engineering Technology and Applied Sciences 6 (1): 37-43. https://doi.org/10.30931/jetas.891679.
EndNote
Turgay ME (01 Nisan 2021) Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique. Journal of Engineering Technology and Applied Sciences 6 1 37–43.
IEEE
[1]M. E. Turgay, “Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique”, Journal of Engineering Technology and Applied Sciences, c. 6, sy 1, ss. 37–43, Nis. 2021, doi: 10.30931/jetas.891679.
ISNAD
Turgay, Muttalip Ergun. “Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique”. Journal of Engineering Technology and Applied Sciences 6/1 (01 Nisan 2021): 37-43. https://doi.org/10.30931/jetas.891679.
JAMA
1.Turgay ME. Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique. Journal of Engineering Technology and Applied Sciences. 2021;6:37–43.
MLA
Turgay, Muttalip Ergun. “Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique”. Journal of Engineering Technology and Applied Sciences, c. 6, sy 1, Nisan 2021, ss. 37-43, doi:10.30931/jetas.891679.
Vancouver
1.Muttalip Ergun Turgay. Comparison of Gamma Sources (Cobalt and Cesium) for Density Measurement of Metals and Alloys via Using Transmission Technique. Journal of Engineering Technology and Applied Sciences. 01 Nisan 2021;6(1):37-43. doi:10.30931/jetas.891679
Cited By
Shielding Effect of Aluminum Against Cs-137 Source, According to Gamma Ray Transmission Technique
Journal of Engineering Technology and Applied Sciences
https://doi.org/10.30931/jetas.1027422