Introduction: In prosthetic dentistry, dental implants are a popular and effective way to replace missing teeth. In implant-supported fixed dental restorations, there are two prosthetic fixation options: screw-retained or cement-retained. Although both treatment options can be used predictably, they each have their own advantages, disadvantages, and limitations. Aim of this study is to evaluate the biomechanical features of hybrid cement-screw retained prosthesis system by using the 3D finite element method.

Materials and Methods: Three 3-dimensional CAD model of a single dental implant and their screw-retained, cement-retained, and cement-screw-retained implant-supported zirconium-based crowns with their components were constructed. An average occlusal force of 100 N were applied in an oblique (45⁰) direction buccolingually and mesiodistally (distal fossa area 1 mm2). Then the values of the stresses generated in the prosthesis, abutment, implant, and supporting alveolar bone were calculated using 3-dimensional finite element analysis.

Results: Stresses were greater in cement-retained than screw-retained and cement-screw-retained. The amount of stress in the cement- and screw-retained system was cement and screw system.

Discussion: Within the limitations of the investigation, it was determined that retention system changes affected the force distribution.

Conclusion: The obtained results could prove useful for implantologists. Although in vitro mechanical tests are valuable aids in the comparison of restoration properties, data obtained from these studies are useful for comparative purposes only, and direct extrapolation to the clinical situation should be made with caution and supported with long-term clinical studies.

Keywords: The Combined Cement- and Screw-Retained Implant-Supported, 3-dimensional finite element analysis, zirconia crowns.

Anahtar Kelimeler

Kaynakça

  1. References

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

7 Ekim 2018

Gönderilme Tarihi

7 Ağustos 2018

Kabul Tarihi

7 Ekim 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 2 Sayı: 1

Kaynak Göster

APA
Tuzlalı, M., & Arısan, V. (2018). Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA. Journal of Meffert Implant Institute, 2(1), 7-7. https://izlik.org/JA68AX23WK
AMA
1.Tuzlalı M, Arısan V. Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA. J Meffert Imp Inst. 2018;2(1):7-7. https://izlik.org/JA68AX23WK
Chicago
Tuzlalı, Mesut, ve Volkan Arısan. 2018. “Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA”. Journal of Meffert Implant Institute 2 (1): 7-7. https://izlik.org/JA68AX23WK.
EndNote
Tuzlalı M, Arısan V (01 Ekim 2018) Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA. Journal of Meffert Implant Institute 2 1 7–7.
IEEE
[1]M. Tuzlalı ve V. Arısan, “Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA”, J Meffert Imp Inst, c. 2, sy 1, ss. 7–7, Eki. 2018, [çevrimiçi]. Erişim adresi: https://izlik.org/JA68AX23WK
ISNAD
Tuzlalı, Mesut - Arısan, Volkan. “Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA”. Journal of Meffert Implant Institute 2/1 (01 Ekim 2018): 7-7. https://izlik.org/JA68AX23WK.
JAMA
1.Tuzlalı M, Arısan V. Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA. J Meffert Imp Inst. 2018;2:7–7.
MLA
Tuzlalı, Mesut, ve Volkan Arısan. “Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA”. Journal of Meffert Implant Institute, c. 2, sy 1, Ekim 2018, ss. 7-7, https://izlik.org/JA68AX23WK.
Vancouver
1.Mesut Tuzlalı, Volkan Arısan. Biomechanical Considerations of The Combined Cement- and Screw-Retained Implant-Supported Zirconia Crowns: A 3D-FEA. J Meffert Imp Inst [Internet]. 01 Ekim 2018;2(1):7-. Erişim adresi: https://izlik.org/JA68AX23WK