Öz

Aim: This study compared the malposition rates of fixed and adjustable suspensory button implants used for femoral fixation of the graft during anterior cruciate ligament (ACL) reconstruction and examined the effectiveness of intraoperative imaging in managing these complications. Methods: This retrospective study evaluated 187 patients who underwent arthroscopic ACL reconstruction. The patients included in the study were categorized into two groups according to the type of femoral suspensory button (FSB) implant used: fixed suspensory button (FxSB) and adjustable suspensory button (ASB). Button malpositions were determined and recorded with intraoperative images in cases where fluoroscopy was used and postoperative X-ray radiographs in cases where fluoroscopy was not used. Malposition rates were compared between the two groups, and risk analysis was performed. Results: The FxSB implant was used in 89 patients, and the ASB implant was used in 98 patients. Malposition was detected in 24 patients (12.8%). When the FxSB and ASB implant groups were analyzed separately, the number and rate of malpositions were 5 (5.6%) and 19 (19.3%), respectively (p=.0123). Regression analysis showed that the risk of malposition was 3.5 times higher in the ASB implant group than in the FxSB implant group (M: 3.57 (p=.0017) 95% CI (1.36-10.1)). Conclusion: This study found that ASB implants used in ACL reconstruction resulted in a higher rate of button malposition than FxSB implants. In addition, intraoperative fluoroscopy was found to be a useful method to detect malpositions in all FSB implants and allow for proper button positioning with intraoperative interventions.

Anahtar Kelimeler

Kaynakça

  1. 1.Rousseau R, Labruyere C, Kajetanek C, et al. Complications after anterior cruciate ligament reconstruction and their relation to the type of graft: a prospective study of 958 cases. Am J Sports Med. 2019;47(11):2543–9. [Crossref]
  2. 2.Marx RG, Spock CR. Complications following hamstring anterior cruciate ligament reconstruction with femoral cross-pin fixation. Arthroscopy. 2005;21(6):762-e1. [Crossref]
  3. 3.Almazán A, Miguel A, Odor A, et al. Intraoperative incidents and complications in primary arthroscopic anterior cruciate ligament reconstruction. Arthroscopy. 2006;22(11):1211–7. [Crossref]
  4. 4.Gürpınar T, Polat B, Eren M, et al. The effect of soft tissue interposition of the Endobutton on clinical results and on its postoperative migration after single-bundle anterior cruciate ligament reconstruction. Knee. 2020;27(6):1980–7. [Crossref]
  5. 5.Simonian PT, Behr CT, Stechschulte Jr DJ, et al. Potential pitfall of the EndoButton. Arthroscopy. 1998;14(1):66–9. [Crossref]
  6. 6.Sabat D, Sehrawat R, Kumar V. A percutaneous technique to reposition the cortical button of adjustable-loop devices in anterior cruciate ligament reconstruction. Arthrosc Tech. 2019;8(11):e1273–6. [Crossref]
  7. 7.Smith PA, Piepenbrink M, Smith SK, et al. Adjustable-versus fixed-loop devices for femoral fixation in ACL reconstruction: an in vitro full-construct biomechanical study of surgical technique–based tibial fixation and graft preparation. Orthop J Sports Med. 2018;6(4):2325967118768743. [Crossref]
  8. 8.Petre BM, Smith SD, Jansson KS, et al. Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study. Am J Sports Med. 2013;41(2):416–22. [Crossref]

Ayrıntılar

Birincil Dil

İngilizce

Konular

Ortopedi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Haziran 2025

Gönderilme Tarihi

4 Mart 2025

Kabul Tarihi

16 Haziran 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 8 Sayı: 2

Kaynak Göster

APA
Akgün, E., Kaya, İ., Tepedelenlioğlu, H. E., Bircan, R., & Karakoç, Y. (2025). Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction. Journal of Cukurova Anesthesia and Surgical Sciences, 8(2), 117-122. https://doi.org/10.36516/jocass.1650623
AMA
1.Akgün E, Kaya İ, Tepedelenlioğlu HE, Bircan R, Karakoç Y. Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction. J Cukurova Anesth Surg. 2025;8(2):117-122. doi:10.36516/jocass.1650623
Chicago
Akgün, Erkan, İbrahim Kaya, Hüseyin Emre Tepedelenlioğlu, Resul Bircan, ve Yaman Karakoç. 2025. “Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction”. Journal of Cukurova Anesthesia and Surgical Sciences 8 (2): 117-22. https://doi.org/10.36516/jocass.1650623.
EndNote
Akgün E, Kaya İ, Tepedelenlioğlu HE, Bircan R, Karakoç Y (01 Haziran 2025) Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction. Journal of Cukurova Anesthesia and Surgical Sciences 8 2 117–122.
IEEE
[1]E. Akgün, İ. Kaya, H. E. Tepedelenlioğlu, R. Bircan, ve Y. Karakoç, “Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction”, J Cukurova Anesth Surg, c. 8, sy 2, ss. 117–122, Haz. 2025, doi: 10.36516/jocass.1650623.
ISNAD
Akgün, Erkan - Kaya, İbrahim - Tepedelenlioğlu, Hüseyin Emre - Bircan, Resul - Karakoç, Yaman. “Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction”. Journal of Cukurova Anesthesia and Surgical Sciences 8/2 (01 Haziran 2025): 117-122. https://doi.org/10.36516/jocass.1650623.
JAMA
1.Akgün E, Kaya İ, Tepedelenlioğlu HE, Bircan R, Karakoç Y. Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction. J Cukurova Anesth Surg. 2025;8:117–122.
MLA
Akgün, Erkan, vd. “Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction”. Journal of Cukurova Anesthesia and Surgical Sciences, c. 8, sy 2, Haziran 2025, ss. 117-22, doi:10.36516/jocass.1650623.
Vancouver
1.Erkan Akgün, İbrahim Kaya, Hüseyin Emre Tepedelenlioğlu, Resul Bircan, Yaman Karakoç. Comparison of Perioperative Malposition Rates of Fixed and Adjustable Suspensory Button Implants Used for Femoral Fixation During Anterior Cruciate Ligament Reconstruction. J Cukurova Anesth Surg. 01 Haziran 2025;8(2):117-22. doi:10.36516/jocass.1650623

Bu dergide yayımlanan tüm içerik, Creative Commons Atıf-GayriTicari-TürevEserYok 4.0 Uluslararası Lisansı (CC BY-NC-ND 4.0) kapsamında lisanslanmıştır.

download?token=eyJhdXRoX3JvbGVzIjpbXSwiZW5kcG9pbnQiOiJqb3VybmFsIiwib3JpZ2luYWxuYW1lIjoiYnktbmMtbmRbMV0ucG5nIiwicGF0aCI6ImRjMmUvOGY3Mi8yOTAyLzY5ZjRiZGU2NDlkMDUzLjM0MjgyNDcwLnBuZyIsImV4cCI6MTc3NzY1MDY3OCwibm9uY2UiOiJmODZhMDJlNWQ5M2M3N2JhMjUzYjMzOTE3OTI1NGNiMyJ9.fEXKQdlZxq9vl1s_qY4iq7tJSpiFA7z3ZyfKXacu1Ao

🔗 https://creativecommons.org/licenses/by-nc-nd/4.0/