Our arteriovenous fistula experiences with grafts in hemodialysis patients
Abstract
Aim: In patients whose life is dependent on hemodialysis, the most suitable vascular access routes are arteriovenous fistulas made with native vessels. However, in patients whose natural vessels are depleted, or not suitable, arteriovenous fistulas can be opened with artificial grafts. Our aim is to examine arteriovenous fistulas opened with synthetic grafts in hemodialysis patients who do not have native vascular access in the upper extremity and share our results.
Methods: Patients who underwent opening of an arteriovenous fistula with a synthetic graft to the upper extremities in Adıyaman University Faculty of Medicine, Cardiovascular Surgery Clinic between December 2012 and December 2018 were examined in this retrospective cohort study. They were screened for age, gender, end-stage renal failure etiology, complications in vascular access site, postoperative follow-up, and duration of use. Primary and secondary patency rates were determined.
Results: It was determined that synthetic grafts were used in 33 (15 males, 18 females) out of 436 arteriovenous fistulas (AVF) opened to 372 patients. The mean age was 59.2 (17) years. Left radiocephalic (RC) straight graft fistula was opened in 2 patients, left brachiocephalic (BC) straight graft fistula was opened in 12, left BC distal loop AVF in 13, right BC distal loop AVF in 1, left brachioaxillary (BA) distal loop AVF in 3 and right BA distal loop was used to open an AVF in 2 patients. Primary cumulative patency rates were as follows: 72% in the 3rd month, 65% in the 6th month, 42.24% in the 12th month. The secondary patency rates were 33.9% in the 60th month, 12% in the 60th month, 96.96% in the 12th and 24th months, 90.28% in the 36th and 48th months, 59.12% in the 60th month and 43.11% in the 72nd month.
Conclusion: In chronic renal failure patients who do not have a natural vascular access routes or whose natural routes have been exhausted, AVFs that are opened to the upper extremities with a synthetic graft are suitable vascular access routes for long-term dialysis.
Methods: Patients who underwent opening of an arteriovenous fistula with a synthetic graft to the upper extremities in Adıyaman University Faculty of Medicine, Cardiovascular Surgery Clinic between December 2012 and December 2018 were examined in this retrospective cohort study. They were screened for age, gender, end-stage renal failure etiology, complications in vascular access site, postoperative follow-up, and duration of use. Primary and secondary patency rates were determined.
Results: It was determined that synthetic grafts were used in 33 (15 males, 18 females) out of 436 arteriovenous fistulas (AVF) opened to 372 patients. The mean age was 59.2 (17) years. Left radiocephalic (RC) straight graft fistula was opened in 2 patients, left brachiocephalic (BC) straight graft fistula was opened in 12, left BC distal loop AVF in 13, right BC distal loop AVF in 1, left brachioaxillary (BA) distal loop AVF in 3 and right BA distal loop was used to open an AVF in 2 patients. Primary cumulative patency rates were as follows: 72% in the 3rd month, 65% in the 6th month, 42.24% in the 12th month. The secondary patency rates were 33.9% in the 60th month, 12% in the 60th month, 96.96% in the 12th and 24th months, 90.28% in the 36th and 48th months, 59.12% in the 60th month and 43.11% in the 72nd month.
Conclusion: In chronic renal failure patients who do not have a natural vascular access routes or whose natural routes have been exhausted, AVFs that are opened to the upper extremities with a synthetic graft are suitable vascular access routes for long-term dialysis.
Keywords
Destekleyen Kurum
Yok
Kaynakça
- 1. Bozkurt O, Topal C, İnanç M. The relationship between dialysis adequacy and the rate of change in uric acid level by hemodialysis. J Surg Med. 2018;2(3):293-7.
- 2. Brescia MJ, Cimino JE, Appel K, Hurwich BJ. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med. 1966;275:1089-92.
- 3. Hodges TC, Fillinger MF, Zwolak RM, Walsh DB, bech F, Cronenwett JL. Longitudinal comparison of dialysis access methods: risk factors for failure. J Vase Surg. 1997;16:1009-19.
- 4. Çekirdekçi A, Rahman A, Burma O, Cihangiroglu M. Polytetraflouroethylene {PTFE) Greftlerle Hemodializ Amaçlı Arterio-Venoz Fistül Uygulamaları. Damar Cerrahisi Dergisi. 2000;3:24-7.
- 5. Baker LD, Johson JM, Gold farb D:Expanded Polytetraflouroeethylene (PTFE) Subcutaneus Conduit: An İmproved Vascular Access for Chronic Hemodialysis. Trans Am Soc Artif İntern Organs 1976;22:382-7.
- 6. Albers FJ. Causes of hemodialysis access failure. Adv Ren Replace Ther 1994;1(2):107-18.
- 7. Beathard GA, Lok CE, Glickman MH, Al-Jaishi AA, Bednarski D, Cull DL, et al. Definitions and End Points for Interventional Studies for Arteriovenous Dialysis Access. Clin J Am Soc Nephrol. 2018;13(3):501-12. doi:10.2215/CJN.11531116
- 8. Leake AE, Yuo TH, Wu T, Fish L, Dillavou ED, Chaer RA, Leers SA, Makaroun MS: Arteriovenous grafts are associated with earlier catheter removal and fewer catheter days in the United States Renal Data Systempopulation. J Vasc Surg 2015;62:123–7.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Kalp ve Damar Cerrahisi
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
1 Temmuz 2020
Gönderilme Tarihi
14 Temmuz 2020
Kabul Tarihi
4 Ağustos 2020
Yayımlandığı Sayı
Yıl 2020 Cilt: 4 Sayı: 7
APA
Güven, C., & Üçkardeş, F. (2020). Our arteriovenous fistula experiences with grafts in hemodialysis patients. Journal of Surgery and Medicine, 4(7), 550-554. https://doi.org/10.28982/josam.769747
AMA
1.Güven C, Üçkardeş F. Our arteriovenous fistula experiences with grafts in hemodialysis patients. J Surg Med. 2020;4(7):550-554. doi:10.28982/josam.769747
Chicago
Güven, Cengiz, ve Fatih Üçkardeş. 2020. “Our arteriovenous fistula experiences with grafts in hemodialysis patients”. Journal of Surgery and Medicine 4 (7): 550-54. https://doi.org/10.28982/josam.769747.
EndNote
Güven C, Üçkardeş F (01 Temmuz 2020) Our arteriovenous fistula experiences with grafts in hemodialysis patients. Journal of Surgery and Medicine 4 7 550–554.
IEEE
[1]C. Güven ve F. Üçkardeş, “Our arteriovenous fistula experiences with grafts in hemodialysis patients”, J Surg Med, c. 4, sy 7, ss. 550–554, Tem. 2020, doi: 10.28982/josam.769747.
ISNAD
Güven, Cengiz - Üçkardeş, Fatih. “Our arteriovenous fistula experiences with grafts in hemodialysis patients”. Journal of Surgery and Medicine 4/7 (01 Temmuz 2020): 550-554. https://doi.org/10.28982/josam.769747.
JAMA
1.Güven C, Üçkardeş F. Our arteriovenous fistula experiences with grafts in hemodialysis patients. J Surg Med. 2020;4:550–554.
MLA
Güven, Cengiz, ve Fatih Üçkardeş. “Our arteriovenous fistula experiences with grafts in hemodialysis patients”. Journal of Surgery and Medicine, c. 4, sy 7, Temmuz 2020, ss. 550-4, doi:10.28982/josam.769747.
Vancouver
1.Cengiz Güven, Fatih Üçkardeş. Our arteriovenous fistula experiences with grafts in hemodialysis patients. J Surg Med. 01 Temmuz 2020;4(7):550-4. doi:10.28982/josam.769747