Araştırma Makalesi

Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles

Cilt: 4 Sayı: 8 1 Ağustos 2020
PDF İndir
TR EN

Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles

Abstract

Aim: Increased fracture angle in the coronal plane results in more instability and complications in femoral neck fractures. Our aim in this study was to analyze biomechanical changes at critical fracture angles (30 degrees, 50 degrees, and 70 degrees) as described in Pauwels classification. Methods: A femur model was obtained by 3D computerized tomography (CT) scanning. The angle of femoral neck fracture in the coronal plane observed on the CT image was created on the model at 30, 50 and 70-degree angles. Three cannulated screws were placed in the inverted triangle position. Screws were named “anterior-superior” (A), “posterior -superior” (B), and “inferior” (C). The obtained three different models were transferred to the ANSYS Workbench program. Von Mises stress distribution on the screws and distal fracture surfaces were recorded. Results: In the 30-degree fracture model, the maximum stress was 18.062 MPa on the "A" screw. It was 22.13 MPa on screw "B" and 16.21 MPa on screw "C". In the 50-degree fracture model, the maximum stress values were 68.04 MPa, 89.52 MPa and 48.94 MPa in screws "A", "B", and "C", respectively. In the 70-degree fracture model, the maximum stress values were 120.02 MPa, 138.32 MPa and 98.37 MPa in screws "A", "B", and "C", respectively. The stress values on the distal fracture surfaces were 13.54 MPa, 43.80 MPa, and 50.07 MPa in the 30, 50, and 70-degree models, respectively. Conclusion: Increasing fracture angle from 30 to 50 degrees in femoral neck fractures significantly increases the stress on the distal fracture surface and implants. However, this increase is minimal at angles higher than 50 degrees.

Keywords

Teşekkür

We would like to thank Ahmet Çankaya, who made the modelling work for the purposes of this study.

Kaynakça

  1. 1. Grosso MJ, Danoff JR, Murtaugh TS, Trofa DP, Sawires AN, Macaulay WB. Hemiarthroplasty for Displaced Femoral Neck Fractures in the Elderly Has a Low Conversion Rate. J Arthroplasty. 2017 Jan;32(1):150-4. doi: 10.1016/j.arth.2016.06.048.
  2. 2. Panteli M, Rodham P, Giannoudis PV. Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly. Injury. 2015 Mar;46(3):445-52. doi: 10.1016/j.injury.2014.12.031.
  3. 3. Collinge CA, Mir H, Reddix R. Fracture morphology of high shear angle "vertical" femoral neck fractures in young adult patients. J Orthop Trauma. 2014 May;28(5):270-5. doi: 10.1097/BOT.0000000000000014.
  4. 4. Pauyo T, Drager J, Albers A, Harvey EJ. Management of femoral neck fractures in the young patient: A critical analysis review. World J Orthop. 2014 Jul 18;5(3):204-17. doi: 10.5312/wjo.v5.i3.204.
  5. 5. Li J, Wang M, Li L, Zhang H, Hao M, Li C, Han L, Zhou J, Wang K. Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures. J Orthop Surg Res. 2018 Oct 29;13(1):272. doi: 10.1186/s13018-018-0970-3.
  6. 6. Slobogean GP, Sprague SA, Scott T, McKee M, Bhandari M. Management of young femoral neck fractures: is there a consensus? Injury. 2015 Mar;46(3):435-40. doi: 10.1016/j.injury.2014.11.028.
  7. 7. Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, Qingwen Z. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharmacother. 2019 Apr;112:108658. doi: 10.1016/j.biopha.2019.108658.
  8. 8. Cha YH, Yoo JI, Hwang SY, Kim KJ, Kim HY, Choy WS, Hwang SC. Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods. Clin Orthop Surg. 2019 Mar;11(1):1-14. doi: 10.4055/cios.2019.11.1.1.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Ortopedi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Ağustos 2020

Gönderilme Tarihi

14 Ağustos 2020

Kabul Tarihi

5 Eylül 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 4 Sayı: 8

Kaynak Göster

APA
Öner, K., Paksoy, A. E., & Özer, A. (2020). Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles. Journal of Surgery and Medicine, 4(8), 660-663. https://doi.org/10.28982/josam.780442
AMA
1.Öner K, Paksoy AE, Özer A. Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles. J Surg Med. 2020;4(8):660-663. doi:10.28982/josam.780442
Chicago
Öner, Kerim, Ahmet Emre Paksoy, ve Alaettin Özer. 2020. “Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles”. Journal of Surgery and Medicine 4 (8): 660-63. https://doi.org/10.28982/josam.780442.
EndNote
Öner K, Paksoy AE, Özer A (01 Ağustos 2020) Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles. Journal of Surgery and Medicine 4 8 660–663.
IEEE
[1]K. Öner, A. E. Paksoy, ve A. Özer, “Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles”, J Surg Med, c. 4, sy 8, ss. 660–663, Ağu. 2020, doi: 10.28982/josam.780442.
ISNAD
Öner, Kerim - Paksoy, Ahmet Emre - Özer, Alaettin. “Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles”. Journal of Surgery and Medicine 4/8 (01 Ağustos 2020): 660-663. https://doi.org/10.28982/josam.780442.
JAMA
1.Öner K, Paksoy AE, Özer A. Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles. J Surg Med. 2020;4:660–663.
MLA
Öner, Kerim, vd. “Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles”. Journal of Surgery and Medicine, c. 4, sy 8, Ağustos 2020, ss. 660-3, doi:10.28982/josam.780442.
Vancouver
1.Kerim Öner, Ahmet Emre Paksoy, Alaettin Özer. Fixation of femoral neck fractures with three cannulated screws: biomechanical changes at critical fracture angles. J Surg Med. 01 Ağustos 2020;4(8):660-3. doi:10.28982/josam.780442

Cited By