Araştırma Makalesi

Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions

Cilt: 5 Sayı: 1 1 Ocak 2021
PDF İndir
EN

Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions

Öz

Background/Aim: Data on the comparison of diagnostic yields of 22-gauge (22G) and 25-gauge (25G) needles used in endoscopic ultrasound guided fine needle aspiration (EUS-FNA) biopsy usually include solid pancreatic masses. In our study, we compared the diagnostic yield, safety, and performance characteristics of 22G and 25G needles in the EUS-FNA of various solid lesions in or adjacent to the upper gastrointestinal wall and suspicious lymph nodes. Methods: In this retrospective cohort study, we enrolled patients who underwent EUS-FNA using 22G and 25G needles between August 2018 and January 2020. We compared EUS-FNA results with histological findings in operated patients and long-term clinical follow-up results in non-operated patients. Results: Seventy-nine patients (40 patients with 22G needles) were enrolled. There were pancreatic solid masses in 50 (63.3%) patients, subepithelial lesions in 13 (16.5%), suspicious lymph nodes in 12 (15.2%), and various lesions adjacent to the lumen in 4 (5.1%) patients. The diagnostic yield of 22G and 25G needles were 92.5% and 94.9%, respectively, which were similar (P=0.664). EUS-FNA of 2 pancreatic masses required a crossover from a 22G needle to a 25G needle due to lesion stiffness. The technical success rate for the lesion type was 100% and 95% for 25G and 22G needles, respectively (P=0.160). No major complications were observed with either needle. Conclusions: The 25G needle was not superior to the 22G needle in terms of diagnostic yield and safety profile in EUS-FNA of solid lesions. The use of 25G needles in hard masses can provide ease of puncture.

Anahtar Kelimeler

Kaynakça

  1. 1. Yamao K, Sawaki A, Mizuno N, Shimizu Y, Yatabe Y, Koshikawa T. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB): past, present, and future. J Gastroenterol. 2005;40(11):1013-23. doi: 10.1007/s00535-005-1717-6
  2. 2. Camellini L, Carlinfante G, Azzolini F, Iori V, Cavina M, Sereni G, et al. A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions. Endoscopy. 2011;43(8):709-15. doi: 10.1055/s-0030-1256482.
  3. 3. Fabbri C, Polifemo AM, Luigiano C, Cennamo V, Baccarini P, Collina G, et al. Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: a prospective comparative study with randomisation of needle sequence. Dig Liver Dis. 2011;43(8):647-52. doi: 10.1016/j.dld.2011.04.005.
  4. 4. Vilmann P, SĂftoiu A, Hollerbach S, Guldhammer Skov B, Linnemann D, Popescu CF, et al. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25gauge EUS-FNA needles in solid masses. Scand J Gastroenterol. 2013;48(7):877-83. doi: 10.3109/00365521.2013.799222.
  5. 5. Affi A, Vazquez-Sequeiros E, Norton ID, Clain JE, Wiersema MJ. Acute extraluminal hemorrhage associated with EUS-guided fine needle aspiration: frequency and clinical significance. Gastrointest Endosc. 2001;53(2):221-25. doi: 10.1067/mge.2001.111391.
  6. 6. Affolter KE, Schmidt RL, Matynia AP, Adler DG, Factor RE. Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis. Dig Dis Sci. 2013;58(4):1026-34. doi: 10.1007/s10620-012-2439-2.
  7. 7. Guedes HG, Hourneaux de Moura DT, Duarte RB, Coronel Cordero MA, Lera Dos Santos ME, Cheng S, et al. A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis. Clinics. 2018;73: e261. doi: 10.6061/clinics/2018/e261.
  8. 8. Alper E, Onur I, Arabul M, Unsal B. Endoscopic ultrasound-guided tissue sampling: How can we improve the results? Turk J Gastroenterol. 2016;27(1):1-3. doi: 10.5152/tjg.2015.150497.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Gastroenteroloji ve Hepatoloji

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Ocak 2021

Gönderilme Tarihi

12 Ocak 2021

Kabul Tarihi

9 Şubat 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 5 Sayı: 1

Kaynak Göster

APA
Ogutmen Koc, D., & Gökden, Y. (2021). Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. Journal of Surgery and Medicine, 5(1), 22-25. https://doi.org/10.28982/josam.859352
AMA
1.Ogutmen Koc D, Gökden Y. Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. J Surg Med. 2021;5(1):22-25. doi:10.28982/josam.859352
Chicago
Ogutmen Koc, Deniz, ve Yasemin Gökden. 2021. “Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions”. Journal of Surgery and Medicine 5 (1): 22-25. https://doi.org/10.28982/josam.859352.
EndNote
Ogutmen Koc D, Gökden Y (01 Ocak 2021) Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. Journal of Surgery and Medicine 5 1 22–25.
IEEE
[1]D. Ogutmen Koc ve Y. Gökden, “Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions”, J Surg Med, c. 5, sy 1, ss. 22–25, Oca. 2021, doi: 10.28982/josam.859352.
ISNAD
Ogutmen Koc, Deniz - Gökden, Yasemin. “Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions”. Journal of Surgery and Medicine 5/1 (01 Ocak 2021): 22-25. https://doi.org/10.28982/josam.859352.
JAMA
1.Ogutmen Koc D, Gökden Y. Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. J Surg Med. 2021;5:22–25.
MLA
Ogutmen Koc, Deniz, ve Yasemin Gökden. “Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions”. Journal of Surgery and Medicine, c. 5, sy 1, Ocak 2021, ss. 22-25, doi:10.28982/josam.859352.
Vancouver
1.Deniz Ogutmen Koc, Yasemin Gökden. Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. J Surg Med. 01 Ocak 2021;5(1):22-5. doi:10.28982/josam.859352