Background/Aim: Plate screw fixation is an important method in femoral shaft fractures. Although there are many studies on plate screw fixation, the ideal plate screw configuration has not yet been determined. In our study, we investigated the optimal plate-screw configuration in femoral shaft fractures using the 3D finite element analysis method. Methods: A fracture model was created by removing the segment from the femur model obtained from 3D computed tomography scanning. Five different fixation models were designed using a 4.5 mm diameter steel locked femoral shaft plate and different screw configurations. Screws with double cortex locks of 4.5 mm in width were used in different configurations. To evaluate the effect of screw diameter, a 5.5 mm diameter screw with a double cortex lock was used in one model. Static linear analyses of these prepared Finite Element models were performed using Ansys Workbench 2020 R2 Finite Elements software. Results: The maximum stresses on the plate at the fracture sites were 156 MPa at 200 N, and 546 MPa at 700 N in model 1, 274 MPa at 200 N, and 784 MPa at 700 N in Model 2, 274 MPa at 200 N, and 959 MPa at 700 N in Model 3, 389 MPa at 200 N, and 1118 MPa at 700 N in Model 4, and 200 N is 274 MPa, and 961 MPa at 700 N in Model 5. Conclusion: The stress on the plate in the fracture area increases in parallel with the increase in screw diameter, plate length and plate working distance. Filling all screw holes does not alter the stress on the plate at the fracture line level.

Anahtar Kelimeler

Kaynakça

  1. 1. Gösling T, Krettek C. Femoral shaft fractures. Der Unfallchirurg. 2019;122:59–75.
  2. 2. Weiss RJ, Montgomery SM, Al Dabbagh Z, Jansson KA. National data of 6409 Swedish inpatients with femoral shaft fractures: Stable incidence between 1998 and 2004. Injury. 2009;40:304–8.
  3. 3. Li AB, Zhang WJ, Guo WJ, Wang XH, Jin HM, Zhao YM. Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures. Medicine. 2016;95:e4248
  4. 4. Scannell BP, Waldrop NE, Sasser HC, Sing RF, Bosse MJ. Skeletal traction versus external fixation in the initial temporization of femoral shaft fractures in severely injured patients. Journal of Trauma. 2010;68:633–40.
  5. 5. Zlowodzki M, Vogt D, Cole PA, Kregor PJ. Plating of Femoral Shaft Fractures: Open Reduction and Internal Fixation Versus Submuscular Fixation. Journal of Trauma. 2007; 63:1061–5.
  6. 6. Crist BD, Wolinsky PR. Reaming does not add significant time to intramedullary nailing of diaphyseal fractures of the tibia and femur. Journal of Trauma.2009;67:727–34.
  7. 7. Köseoğlu E, Durak K, Bilgen MS, Küçükalp A, Bayyurt S. Comparison of two biological internal fixation techniques in the treatment of adult femur shaft fractures (plate-screws and locked intramedullary nail). Turkısh Journal of Trauma.2011;17:159-65.
  8. 8. Apivatthakakul T, Chiewcharntanakit S. Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop. 2009;33:1119–26.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Ortopedi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Mayıs 2021

Gönderilme Tarihi

22 Nisan 2021

Kabul Tarihi

1 Haziran 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 5 Sayı: 5

Kaynak Göster

APA
Saraç, Ü., Karadeniz, S., & Özer, A. (2021). Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis. Journal of Surgery and Medicine, 5(5), 540-543. https://doi.org/10.28982/josam.925624
AMA
1.Saraç Ü, Karadeniz S, Özer A. Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis. J Surg Med. 2021;5(5):540-543. doi:10.28982/josam.925624
Chicago
Saraç, Ünal, Sercan Karadeniz, ve Alaettin Özer. 2021. “Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis”. Journal of Surgery and Medicine 5 (5): 540-43. https://doi.org/10.28982/josam.925624.
EndNote
Saraç Ü, Karadeniz S, Özer A (01 Mayıs 2021) Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis. Journal of Surgery and Medicine 5 5 540–543.
IEEE
[1]Ü. Saraç, S. Karadeniz, ve A. Özer, “Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis”, J Surg Med, c. 5, sy 5, ss. 540–543, May. 2021, doi: 10.28982/josam.925624.
ISNAD
Saraç, Ünal - Karadeniz, Sercan - Özer, Alaettin. “Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis”. Journal of Surgery and Medicine 5/5 (01 Mayıs 2021): 540-543. https://doi.org/10.28982/josam.925624.
JAMA
1.Saraç Ü, Karadeniz S, Özer A. Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis. J Surg Med. 2021;5:540–543.
MLA
Saraç, Ünal, vd. “Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis”. Journal of Surgery and Medicine, c. 5, sy 5, Mayıs 2021, ss. 540-3, doi:10.28982/josam.925624.
Vancouver
1.Ünal Saraç, Sercan Karadeniz, Alaettin Özer. Ideal plate screw configuration in femoral shaft fractures: 3D finite element analysis. J Surg Med. 01 Mayıs 2021;5(5):540-3. doi:10.28982/josam.925624