Araştırma Makalesi

DEVELOPMENT OF ELECTROCHEMICAL SENSORS FOR QUANTITATIVE ANALYSIS OF METHYLDOPA AT MODIFIED-GCE AND PGE ELECTRODES BY VOLTAMMETRY

Cilt: 4 Sayı: 4 7 Kasım 2020
PDF İndir
EN

DEVELOPMENT OF ELECTROCHEMICAL SENSORS FOR QUANTITATIVE ANALYSIS OF METHYLDOPA AT MODIFIED-GCE AND PGE ELECTRODES BY VOLTAMMETRY

Abstract

Methyldopa is one of the important drugs used in the treatment of high blood pressure (hypertension). In addition to various methods such as chromatographic and spectrophotometric methods, electrochemical methods are used for the determination of methyldopa. However, poly (p-aminobenzene sulfonic acid), pen-tip graphite electrode (PGE) study was not found in the literature search. Modified electrodes are important because they increase the sensitivity of the analysis. Furthermore, electrochemical methods have advantages such as being faster and cheaper than other instrumental analysis methods, being more sensitive, not requiring long pretreatments in the preparation of samples. In this study, the glassy carbon electrode (GCE) was modified with poly(p-aminobenzene sulfonic acid) to prepare poly (p-aminobenzene sulfonic acid) -modified glassy carbon electrodes. Cyclic voltammetry (CV) technique was used for the electropolymerization process. Methyldopa was selected in various concentrations of phosphate pH 7.40 buffer, anodic and cathodic voltamograms were taken and oxidation and reduction properties were investigated. Measurements were taken at different scanning rates by CV technique and the current type of methyldopa was determined. Peak flow-concentration graphs were drawn from the measurements taken by Differential Pulse Voltammetry (DPV) technique and the linearity range was 0.020- 2.500 µM for modified-GCE and 0.020-2.820 µM for PGE. The limit of detection (LOD) was calculated as 0.006 µM for modified-GCE, 0.012 µM for PGE. The limit of quantification (LOQ) was calculated as 0.020 µM for modified-GCE and 0.040 µM for PGE.

Keywords

Kaynakça

  1. AZARI, S., and ZOU, L. 2012, Using zwitter ionic amino acid l-DOPA tomodify the surface of thin film composite polyamide reverse osmosis membranes to increase their fouling resistance. J. Memb. Sci., 401–402, 68–75.
  2. BASTIDE, M.F., et al., 2015, Pathophysiology of L-dopa-induced motor and non-motor complications in Parkinson’sdisease. Prog. Neurobiol., 132, 96–168.
  3. BENZA K.R., GASH B., KLEBOVICH I, 1996, Determination of Methyldopa in Human Plasma by Validated HPLC with fluorescence detection, Journal of Chromatography, 730, 125-131.
  4. DE D, P., DI GIOVANNI, G., and Millan, M.J., 2017, Expanding the repertoire of L-DOPA’sactions: A comprehensive review of its functional neurochemistry. Prog. Neurobiol., 151, 57–100.
  5. DI GIOVANNI, G., CHAGRAOUI, A., PUGINIER, E., GALATI, S., and DE DEURWAERDÈRE, P., 2019, Reciprocal interaction between monoaminergic systems and the pedunculopontine nucleus: Implication in the mechanism of L-DOPA. Neurobiol. Dis., 128, 9–18.
  6. FOULADGAR, M., KARIMI, M.H., 2013, Ionic Liquid/Multiwall Carbon Nanotubes Paste Electrode for Square WaweVoltammetic Determination of Methyldopa, 19, 1163-70.
  7. GHOLIVAND M.B., AMIRI, M., 2009, Preparation of Polypyrrole/Nuclear Fast Red Films on Gold Electrode and Its Application on the Electrocatalytic Determination of Methyldopa and Ascorbic Acid, Electroanalysis, 21,22, 2461-67.
  8. HAUSER, R.A. 2009, Levodopa: Past, Present, and Future. Eur. Neurol., 62 (1), 1–8.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

7 Kasım 2020

Gönderilme Tarihi

14 Eylül 2020

Kabul Tarihi

9 Ekim 2020

Yayımlandığı Sayı

Yıl 1970 Cilt: 4 Sayı: 4

Kaynak Göster

APA
Yanık, S., B. Kurt, S., Ari, B., Demırcı, S., & Yılmaz, S. (2020). DEVELOPMENT OF ELECTROCHEMICAL SENSORS FOR QUANTITATIVE ANALYSIS OF METHYLDOPA AT MODIFIED-GCE AND PGE ELECTRODES BY VOLTAMMETRY. Journal of Scientific Perspectives, 4(4), 223-236. https://izlik.org/JA26TP46MW