Determination of Normal Values for Flash Electroretinogram (FERG) Test
Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi

Rukiye UZUN ARSLAN [1]


Electroretinography is the recording of the electrical potentials when the retinal cells are stimulated with flashlight. In this way, the retinal visual pathways from photoreceptors to amacrine cells can be evaluated as a whole. In this manner, it is possible to evaluate the retinal visual pathways as a whole. In obtaining electroretinography signals; factors such as the device used, the electrode, the methods in the tests performed, and the laboratory conditions play an important role. The obtained signals vary depending on these factors. Therefore, it has become necessary to determine the normal values of each electrophysiological laboratory. In this respect, we aimed to determine normal values for the flash electroretinography test. Flash electroretinography test was applied to individuals who did not have any ocular disease by using the device in Zonguldak Bulent Ecevit University Obesity and Diabetes Research and Application Center. All stages of the test were carried out in accordance with the recommendations of the International Society for Clinical Electrophysiology of Vision. Using the test results, the normal values were calculated in the median and were presented with the upper and lower limits of 95% confidence interval. It is thought that the normal values determined may serve as a reference for newly established laboratory environments.
Elektroretinografi, retinal hücrelerin flaş ışıkla uyarılması durumunda ortaya çıkan elektriksel potansiyellerin kayıt altına alınmasıdır. Bu sayede fotoreseptörlerden amakrin hücrelerine kadar olan retinal görme yolları bir bütün olarak değerlendirilebilmektedir. Böylelikle retinal görme yollarının bir bütün olarak değerlendirilmesi mümkün olabilmektedir. Elektroretinografi sinyallerinin elde edilmesinde; kullanılan cihaz, elektrot, uygulanan testlerdeki yöntemler ve laboratuvar koşulları gibi faktörler önemli bir rol oynamaktadır. Elde edilen sinyaller bu faktörlere bağlı olarak değişkenlik göstermektedir. Bundan dolayı her elektrofizyolojik laboratuvarının kendisine özgü normal değerlerini belirlenmesi zorunlu hale gelmiştir. Bu doğrultuda çalışmamızda flaş elektroretinografi testi için normal değerlerin belirlenmesi amaçlanmıştır. Zonguldak Bülent Ecevit Üniversitesi Obezite ve Diyabet Uygulama ve Araştırma Merkezinde bulunan cihaz kullanılarak oküler herhangi bir rahatsızlığı bulunmayan bireylere flaş elektroretinografi testi uygulanmıştır. Testin tüm aşamaları Uluslararası Elektrofizyoloji Cemiyeti’nin önerileri doğrultusunda gerçekleştirilmiştir. Elde edilen test sonuçları kullanılarak normal değerler ortanca cinsinden hesaplanmış olup %95 güven aralığındaki alt ve üst sınır değerleriyle ortaya konulmuştur. Belirlenen normal değerlerin yeni kurulan laboratuvar ortamlarına referans teşkil edebileceği düşünülmektedir.
  • Aksu, S., Kurt, A., Soyata, AZ., Saçar, KT., Taşdelen, S., Karamürsel, S. 2019. Elektroretinografi ve görsel uyarılmış potansiyel ölçümlerinde zenon ve LED ışık kaynaklarının karşılaştırılması. Anadolu Klin., 24(2):78-86. https://doi. org/10.21673/anadoluklin.472427
  • Bağkesen, H., Bayer, A., Uysal, Y., Sobacı, G. 2012. Multifokal elektroretinogram (mfERG) kadran ve halka analizi için normal değerlerimiz. Retina-J. Ret. Vit. Dis., 20(3):199-202.
  • Barraco, R., Adorno, DP., Brai, M. 2011. An approach based on wavelet analysis for feature extraction in the a-wave of the electroretinogram. Comput. Meth. Prog. Bio,. 104(3):316-324. https://doi.org/10.1016/j.cmpb.2011.05.001
  • Celesia, GG., Kaufman, D. 1985. Pattern ERGs and visual evoked potentials in maculopathies and optic nerve diseases. Invest. Ophth. Vis. Sci., 26(5):726-735.
  • Gauvin, M., Lina, JM., Lachapelle, P. 2014. Advance in ERG analysis: from peak time and amplitude to frequency, power, and energy. Biomed. Res. Int, 2014, 1-11. http://dx.doi. org/10.1155/2014/246096
  • Gündoğan, FÇ., Erdem, Ü., Sobacı, G., Bayraktar, Z. 2006. Desen elektroretinogram (PERG) normal değerlerimiz. Gülhane TD, 48(1):19-21.
  • Gündoğan, FÇ., Erdem, Ü., Hamurcu, MŞ., Sobacı, G., Bayraktar, M. Z. 2006. Flaş elektroretinogram (FERG) normal değerlerimiz. Gülhane TD, 48(1):14-18.
  • Güven, A. 2005. Göze ait elektrofizyolojik sinyaller kullanılarak yapay sinir ağları destekli bazı göz hastalıklarının teşhisi. Doktora Tezi, Erciyes Üniversitesi, 105 s.
  • Güven, A., Kara, S. 2006. Diagnosis of the macular diseases from pattern electroretinography signals using artificial neural networks. Expert. Syst. Appl., 30(2):361-366. https://doi. org/10.1016/j.eswa.2005.07.015
  • Hood, DC., Birch, D. G. 1993. Human cone receptor activity: The leading edge of the a–wave and models of receptor activity. Visual Neurosci, 10(5):857-871. https://doi.org/10.1017/ S0952523800006076
  • Lai, TY., Kwok, AK., Au, AW., Lam, DS. 2007. Assessment of macular function by multifocal electroretinography following epiretinal membrane surgery with indocyanine green-assisted internal limiting membrane peeling. Graef. Arch. Clin. Exp., 245(1):148-154. https://doi.org/10.1007/s00417-006-0352-0
  • Marmor, MF., Holder, GE., Seeliger, MW., Yamamoto, S. 2004. Standard for clinical electroretinography. Doc. Ophthalmol, 108(1):107-114. https://doi.org/10.1023/B: DOOP.0000036793.44912.45
  • Miguel-Jiménez, JM., Boquete, L., Ortega, S., Rodriguez- Ascariz, JM., Blanco, R. 2010. Glaucoma detection by wavelet-based analysis of the global flash multifocal electroretinogram. Med. Eng. Phys., 32(6):617-622. https:// doi.org/10.1016/j.medengphy.2010.02.019
  • Miguel-Jiménez, JM., Ortega, S., Boquete, L., Rodríguez- Ascariz, JM., Blanco, R. 2011. Multifocal ERG wavelet packet decomposition applied to glaucoma diagnosis. Biomed. Eng. Online, 10(1):37-49. https://doi.org/10.1186/1475- 925X-10-37
  • Miguel-Jiménez, JM., Blanco, R., De-Santiago, L., Fernandez, A., Rodriguez-Ascariz, JM., Barea, R., Boquete, L. 2015. Continuous-wavelet-transform analysis of the multifocal ERG waveform in glaucoma diagnosis. Med. Biol. Eng. Comput., 53(9):771-780. https://doi/10.1007/s11517-015-1287-6
  • Miller, RF., Dowling, JE. 1970. Intracellular responses of the Müller (glial) cells of mudpuppy retina: Their relation to b-wave of the electroretinogram. J. Neurophysiol, 33(3):323- 341. https://doi/10.1152/jn.1970.33.3.323
  • Öner, AÖ. 2004. Oküler klinik elektrofizyoloji. Erciyes Tip Derg., 26(1):33-38.
  • Öztürk, N., Gündüz, MK., Okka, M. 2015. Patern elektroretinografide normal değerler. Retina-J. Ret. Vit. Dis., 23(3):231-236.
  • Sieving, PA., Murayama, K., Naarendorp, F. 1994. Push–pull model of the primate photopic electroretinogram: A role for hyperpolarizing neurons in shaping the b-wave. Vis. Neurosci., 11(3):519-532. https://doi/ 10.1017/s0952523800002431
  • Tzekov, R., Arden, GB. 1999. The electroretinogram in diabetic retinopathy. Surv. Ophthalmol., 44(1):53-60. https:// doi/10.1016/s0039-6257(99)00063-6
  • Uzun, R., İşler, Y., Şenyer Yapıcı, İ., Ayar, O., Erkaymaz, O. 2018. Dalgacık tabanlı temel bileşen analizi ile elektroretinogram sinyallerinde gürültü bastırılması. 2nd International Symposium on Multidisciplinary and Innovative Technologies, s. 10, Ankara.
Birincil Dil tr
Konular Mühendislik
Bölüm Araştırma Makaleleri
Yazarlar

Orcid: 0000-0002-2082-8695
Yazar: Rukiye UZUN ARSLAN
Kurum: ZONGULDAK BÜLENT ECEVİT ÜNİVERSİTESİ
Ülke: Turkey


Tarihler

Yayımlanma Tarihi : 27 Aralık 2020

Bibtex @araştırma makalesi { karaelmasfen847863, journal = {Karaelmas Fen ve Mühendislik Dergisi}, issn = {2146-7277}, address = {Zonguldak Bülent Ecevit Üniversitesi}, publisher = {Bülent Ecevit Üniversitesi}, year = {2020}, volume = {10}, pages = {137 - 141}, doi = {}, title = {Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi}, key = {cite}, author = {Uzun Arslan, Rukiye} }
APA Uzun Arslan, R . (2020). Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi . Karaelmas Fen ve Mühendislik Dergisi , 10 (2) , 137-141 . Retrieved from https://dergipark.org.tr/tr/pub/karaelmasfen/issue/58727/847863
MLA Uzun Arslan, R . "Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi" . Karaelmas Fen ve Mühendislik Dergisi 10 (2020 ): 137-141 <https://dergipark.org.tr/tr/pub/karaelmasfen/issue/58727/847863>
Chicago Uzun Arslan, R . "Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi". Karaelmas Fen ve Mühendislik Dergisi 10 (2020 ): 137-141
RIS TY - JOUR T1 - Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi AU - Rukiye Uzun Arslan Y1 - 2020 PY - 2020 N1 - DO - T2 - Karaelmas Fen ve Mühendislik Dergisi JF - Journal JO - JOR SP - 137 EP - 141 VL - 10 IS - 2 SN - 2146-7277- M3 - UR - Y2 - 2020 ER -
EndNote %0 Karaelmas Fen ve Mühendislik Dergisi Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi %A Rukiye Uzun Arslan %T Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi %D 2020 %J Karaelmas Fen ve Mühendislik Dergisi %P 2146-7277- %V 10 %N 2 %R %U
ISNAD Uzun Arslan, Rukiye . "Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi". Karaelmas Fen ve Mühendislik Dergisi 10 / 2 (Aralık 2020): 137-141 .
AMA Uzun Arslan R . Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi. Karaelmas Fen ve Mühendislik Dergisi. 2020; 10(2): 137-141.
Vancouver Uzun Arslan R . Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi. Karaelmas Fen ve Mühendislik Dergisi. 2020; 10(2): 137-141.
IEEE R. Uzun Arslan , "Flaş Elektroretinogram (fERG) Testi İçin Normal Değerlerin Belirlenmesi", Karaelmas Fen ve Mühendislik Dergisi, c. 10, sayı. 2, ss. 137-141, Ara. 2020