Development of a Ribavirin Selective Potentiometric PVC-Membrane Microsensor based on Ribavirin Imprinted Polymer
Öz
In this study, a molecularly imprinted polymer
(MIP) of ribavirin, which is an antiviral active drug, was synthesized by suspension
polymerization and on the basis of the synthesized polymer, ribavirin selective
potentiometric microsensor was constructed. Potentiometric performance
characteristics of the microsensor was investigated. It was determined that the
sensor membrane at the ratio of 4% MIP, 67% nitrophenyloctylether and 29% polyvinyl
chloride performed the best potentiometric performance characteristics. For
this sensor; linear range, slope, detection limit and response time were
determined as 1×10-5-1.0×10-2 M, 29.8 mV/decade, 8,7×10-6
M, and ~ 10 s, respectively. Potentiometric determinations of ribavirin
in commercial drug samples were successfully performed by using ribavirin
selective microsensor.
Anahtar Kelimeler
Molecular imprinting,Ribavirin,Ion selective sensor,Potentiometry
Kaynakça
- Alarfaj, N. A., El-Toh, M. F., (2012). Determination of the anti-viral drug Ribavirin in dosage forms via micelle-enhanced spectrofluorimetric method. Luminescence, 28(2), 190-194.
- Bochenska, M. (1998). Structural aspects of host molecules acting as ionophores in ion-selective electrodes. Journal of Molecular Structure. 450, 107-115.
- Breadmore, M. C., Theurillat, R., Thormann, W., (2004). Determination of ribavirin in human serum and plasma by capillary electrophoresis. Electrophoresis, 25, 1615-1622.
- Isildak, I., Yolcu, M., Isildak, O., Demirel, N., Topal, G., Hosgoren, H. (2003). All-solid-state PVC membrane Ag+-selective electrodes based on diaza-18-crown-6 compounds. Microchim. Acta. 144, 177-181.
- Javanbakht, M., Fard, S. E., Mohammadi, A., Abdouss, M., Ganjali, M. R., Norouzi, P., Safaraliee, L., (2008). Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids. Anal Chim Acta. 612(1), 65-74.
- Karabörk, M. (2007). İyon Baskılamaya Dayanan Katı-Faz Ekstraksiyonu, Anadolu Üniversitesi, Fen Bilimleri Enstitüsü, Doktara Tezi, Eskişehir.
- Lijke H., Alffenaar, J. W. C., Kok, W. T., Greijdanus, B., Uges, D. R. A., (2012). Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry. Talanta, 88, 385-390.
- Scott, L. J., Perry, C. M., (2002). Interferon-alpha-2b plus ribavirin: a review of its use in the management of chronic hepatitis C. Drugs, 62(3), 507-556.
- Skoog, D. A., West, D. M., Holler, F. J., Crouch, S. R., (2004). Fundamentals of analytical chemistry. Brooks/Cole Thomson Learning Inc.,US.
- Yarman, A. and Scheller, F.W., (2014). The First Electrochemical MIP Sensor for Tamoxifen. Sensors. 14(5), 7647–7654.