Araştırma Makalesi

Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia

Cilt: 5 Sayı: 2 30 Kasım 2022
PDF İndir
EN

Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia

Öz

Magnetic fluid hyperthermia (MFH) is a new generation cancer treatment method under development. One of the challenges that arise in the practical applications of MFH is the limited control of magnetic nanoparticles (MNP). In order to overcome this problem, new approaches are being investigated in MFH tests. Localization of MNP oscillations can be achieved through static magnetic field-free region (FFR) and static magnetic field (SMF) gradients generated by permanent magnets or electromagnets. In this study, Helmholtz coils were used as SMF source to generate gradient patterns (GPs). Finite element method simulation was used to predict GPs that would emerge in the study area. An experiment platform was produced in which the GP would be generated with parametric current changes. Measurements were taken when source currents were (1.1, 1.1 ), (2.2, 2.2), (4.4, 4.4) and (2.2, -2.2) A, respectively. It was observed that FFR form could be manipulated with coil current. The mapping of the GPs and determining FFRs for the use of localized MFH were discussed for the first time in this study. The findings provide insight into which GP is appropriate in which situations in localized MFH.

Anahtar Kelimeler

Kaynakça

  1. [1] Huang J., Zhong X., Wang L., Yang L., Mao H., 2012. Improving the magnetic resonance imaging contrast and detection methods with engineered magnetic nanoparticles. Theranostics, 2, pp. 86–102.
  2. [2] Estelrich J., Sánchez-Martín M.J., Busquets M.A., 2015. Nanoparticles in magnetic resonance imaging: From simple to dual contrast agents. Int. J. Nanomedicine, 10, pp. 1727–1741.
  3. [3] Arruebo M., Fernández-Pacheco R., Ibarra M.R., Santamaría J., 2007. Magnetic nanoparticles for drug delivery. Nano Today, 2, pp. 22–32.
  4. [4] Mura S., Nicolas J., Couvreur, P., 2013. Stimuli-responsive nanocarriers for drug delivery. Nat. Mater., 12, pp. 991–1003.
  5. [5] Mahmoudi K., Bouras A., Bozec D., Ivkov R., Hadjipanayis C., 2018. Magnetic hyperthermia therapy for the treatment of glioblastoma: a review of the therapy’s history, efficacy and application in humans. Int. J. Hyperth., 34, pp. 1316–1328.
  6. [6] Zhao L.-Y., Liu J.-Y., Ouyang W.-W., Li D.-Y., Li L., Li L.-Y., Tang J.-T., 2013. Magnetic-mediated hyperthermia for cancer treatment: Research progress and clinical trials. Chinese Phys. B, 22, 108104.
  7. [7] Deatsch A.E., Evans B.A., 2014. Heating efficiency in magnetic nanoparticle hyperthermia. J. Magn. Magn. Mater., 354, pp. 163–172.
  8. [8] Dhavalikar R., Rinaldi C., 2016. Theoretical predictions for spatially-focused heating of magnetic nanoparticles guided by magnetic particle imaging field gradients. J. Magn. Magn. Mater., 419, pp. 267–273.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Metroloji,Uygulamalı ve Endüstriyel Fizik, Biyomedikal Mühendisliği, Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Kasım 2022

Gönderilme Tarihi

8 Eylül 2020

Kabul Tarihi

22 Nisan 2022

Yayımlandığı Sayı

Yıl 2022 Cilt: 5 Sayı: 2

Kaynak Göster

APA
Küçükdermenci, S. (2022). Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia. Kocaeli Journal of Science and Engineering, 5(2), 159-166. https://doi.org/10.34088/kojose.792056
AMA
1.Küçükdermenci S. Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia. KOJOSE. 2022;5(2):159-166. doi:10.34088/kojose.792056
Chicago
Küçükdermenci, Serhat. 2022. “Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia”. Kocaeli Journal of Science and Engineering 5 (2): 159-66. https://doi.org/10.34088/kojose.792056.
EndNote
Küçükdermenci S (01 Kasım 2022) Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia. Kocaeli Journal of Science and Engineering 5 2 159–166.
IEEE
[1]S. Küçükdermenci, “Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia”, KOJOSE, c. 5, sy 2, ss. 159–166, Kas. 2022, doi: 10.34088/kojose.792056.
ISNAD
Küçükdermenci, Serhat. “Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia”. Kocaeli Journal of Science and Engineering 5/2 (01 Kasım 2022): 159-166. https://doi.org/10.34088/kojose.792056.
JAMA
1.Küçükdermenci S. Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia. KOJOSE. 2022;5:159–166.
MLA
Küçükdermenci, Serhat. “Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia”. Kocaeli Journal of Science and Engineering, c. 5, sy 2, Kasım 2022, ss. 159-66, doi:10.34088/kojose.792056.
Vancouver
1.Serhat Küçükdermenci. Mapping of Gradient Patterns Generated with Helmholtz Coils for Localized Magnetic Fluid Hyperthermia. KOJOSE. 01 Kasım 2022;5(2):159-66. doi:10.34088/kojose.792056

Cited By