A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building

Öz

Thermal comfort is basically affected by environmental (mean radiant temperature, indoor air temperature and relative humidity and air velocity) and personal parameters (clothing value and activity level). Mean Radiant Temperature is the most complicated parameter among all thermal comfort parameters due to the difficulty of measurement and calculation processes. Calculation methods are not preferred by the researchers because of the complexity of obtaining angle factors while the measurement methods require very expensive devices such as globe thermometers and radiometers. On the other hand, assumptions are commonly used in thermal comfort studies because of their simplicities. One of the most frequently used assumptions expresses the equality of mean radiant temperature to indoor air temperature. However, the accuracy of this assumption needs further experimental research in order to evaluate thermal comfort, especially in free-running buildings. To this aim, this study proposes to determine the accuracy of the assumption of mean radiant temperature equals to indoor air temperature in a free-running building where Adaptive Thermal Comfort approach is applied in summer condition. Environmental parameters are measured via objective sensors, while adaptive thermal comfort is assessed by a software program. The statistical results show that there are significant deviations between two parameters in summer conditions for a free-running building.

Anahtar Kelimeler

Destekleyen Kurum

yok

Proje Numarası

yok

Teşekkür

yok

Kaynakça

  1. [1] ASHRAE 55, 2017, Thermal Environmental Conditions for Human Occupancy
  2. [2] ISO Standard 7730, 1994, Moderate Thermal Environments-Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort, International Standards Organization, Geneva, Switzerland.
  3. [3] Fanger, P.O., 1970. Thermal comfort. Analysis and applications in environmental engineering. Thermal comfort. Analysis and applications in environmental engineering.
  4. [4] Nicol, F. and Humphreys, M., 2010. Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251. Building and Environment, 45(1), pp.11-17.
  5. [5] De Dear, R.J. and Brager, G.S., 2002. Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55. Energy and Buildings, 34(6), pp.549-561.
  6. [6] Wagner, A., Gossauer, E., Moosmann, C., Gropp, T. and Leonhart, R., 2007. Thermal comfort and workplace occupant satisfaction—Results of field studies in German low energy office buildings. Energy and Buildings, 39(7), pp.758-769.
  7. [7] Pfafferott, J., Herkel, S., Kalz, D.E. and Zeuschner, A., 2007. Comparison of low-energy office buildings in summer using different thermal comfort criteria. Energy and Buildings, 39(7), pp.750-757.
  8. [8] CEN EN 15251, 2007. Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality. Thermal Environment. Lighting and Acoustics. European Committee for Standardization. Brussels, Belgium.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Enerji Sistemleri Mühendisliği (Diğer), Makine Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Mayıs 2021

Gönderilme Tarihi

30 Kasım 2020

Kabul Tarihi

15 Mart 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 4 Sayı: 1

Kaynak Göster

APA
Özbey, M. F., & Turhan, C. (2021). A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building. Kocaeli Journal of Science and Engineering, 4(1), 79-85. https://doi.org/10.34088/kojose.833707
AMA
1.Özbey MF, Turhan C. A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building. KOJOSE. 2021;4(1):79-85. doi:10.34088/kojose.833707
Chicago
Özbey, Mehmet Furkan, ve Cihan Turhan. 2021. “A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building”. Kocaeli Journal of Science and Engineering 4 (1): 79-85. https://doi.org/10.34088/kojose.833707.
EndNote
Özbey MF, Turhan C (01 Mayıs 2021) A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building. Kocaeli Journal of Science and Engineering 4 1 79–85.
IEEE
[1]M. F. Özbey ve C. Turhan, “A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building”, KOJOSE, c. 4, sy 1, ss. 79–85, May. 2021, doi: 10.34088/kojose.833707.
ISNAD
Özbey, Mehmet Furkan - Turhan, Cihan. “A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building”. Kocaeli Journal of Science and Engineering 4/1 (01 Mayıs 2021): 79-85. https://doi.org/10.34088/kojose.833707.
JAMA
1.Özbey MF, Turhan C. A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building. KOJOSE. 2021;4:79–85.
MLA
Özbey, Mehmet Furkan, ve Cihan Turhan. “A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building”. Kocaeli Journal of Science and Engineering, c. 4, sy 1, Mayıs 2021, ss. 79-85, doi:10.34088/kojose.833707.
Vancouver
1.Mehmet Furkan Özbey, Cihan Turhan. A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building. KOJOSE. 01 Mayıs 2021;4(1):79-85. doi:10.34088/kojose.833707

Cited By