TR
EN
Comparison of Two Different Brands of Toric Intraocular Lens Implantation
Öz
Purpose To compare the visual outcomes of Tecnis toric IOL and Acrysof toric IOL implantations in patients with cataract and astigmatism retrospectively.
Methods: Tecnis toric IOLs were implanted in 38 eyes of 38 patients, and Acrysof toric IOLs were implanted in 36 eyes of 36 patients. The patients had cataract and astigmatism. During the surgeries we used 7 kinds of Tecnis toric IOL: ZCT150, ZCT225, ZCT300, ZCT400, ZCT450, ZCT525, and ZCT600, cylindrical power was between 1.50 D and 6.00 D and 7 kinds of Acrysof toric IOL: SN6AT3, SN6AT4, SN6AT5, SN6AT6, SN6AT7, SN6AT8, and SN6AT9, cylindrical power was between 1.50 D and 6.00 D. Uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA), keratometric and refractive measurements, and IOL axis were tested in follow-up examinations.
Results: Postoperative mean spherical and cylindrical values of both groups were significantly lower than those of preoperative values (p<0.05),and postoperative mean UCVA and BCVA levels of both groups were significantly higher than preoperative levels (p<0.05). When we compared the two groups (Tecnis toric and Acrysof toric), there were no significant differences in respect to UCVA, BCVA, spherical and cylindrical values (p>0.05).
Conclusion: Both Tecnis toric and Acrysof toric IOL implantations during cataract extraction operation are effective in reducing astigmatism. Even though postoperative visual acuities of the second group (Acrysof toric) were slightly better than those of the first group (Tecnis toric), the difference was not statistically significant.
Anahtar Kelimeler
Kaynakça
- 1- http://www.who.int/blindness/causes/priority/en/2010.
- 2- Read SA, Collins MJ, Carney LG. A review of astigmatism and its possible genesis. Clin Exp Optom. 2007;90:5–19.
- 3- Hoffmann PC, Hutz WW. Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg. 2010;36:1479–1485.
- 4- Mingo-Botín D, Muñoz-Negrete FJ, Won Kim HR, Morcillo-Laiz R, Rebolleda G, Oblanca N. Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery. J Cataract Refract Surg. 2010;36:1700–1708.
- 5- Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: Correcting astigmatism while controlling axis shift. J Cataract Refract Surg. 1994;20:523–6.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
25 Aralık 2020
Gönderilme Tarihi
25 Eylül 2020
Kabul Tarihi
31 Aralık 2020
Yayımlandığı Sayı
Yıl 2020 Cilt: 1 Sayı: 3
APA
Ucar, F., & Çetinkaya, S. (2020). Comparison of Two Different Brands of Toric Intraocular Lens Implantation. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi, 1(3), 7-13. https://izlik.org/JA92KU45MJ
AMA
1.Ucar F, Çetinkaya S. Comparison of Two Different Brands of Toric Intraocular Lens Implantation. KTOKUSB-D. 2020;1(3):7-13. https://izlik.org/JA92KU45MJ
Chicago
Ucar, Fikret, ve Servet Çetinkaya. 2020. “Comparison of Two Different Brands of Toric Intraocular Lens Implantation”. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi 1 (3): 7-13. https://izlik.org/JA92KU45MJ.
EndNote
Ucar F, Çetinkaya S (01 Aralık 2020) Comparison of Two Different Brands of Toric Intraocular Lens Implantation. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi 1 3 7–13.
IEEE
[1]F. Ucar ve S. Çetinkaya, “Comparison of Two Different Brands of Toric Intraocular Lens Implantation”, KTOKUSB-D, c. 1, sy 3, ss. 7–13, Ara. 2020, [çevrimiçi]. Erişim adresi: https://izlik.org/JA92KU45MJ
ISNAD
Ucar, Fikret - Çetinkaya, Servet. “Comparison of Two Different Brands of Toric Intraocular Lens Implantation”. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi 1/3 (01 Aralık 2020): 7-13. https://izlik.org/JA92KU45MJ.
JAMA
1.Ucar F, Çetinkaya S. Comparison of Two Different Brands of Toric Intraocular Lens Implantation. KTOKUSB-D. 2020;1:7–13.
MLA
Ucar, Fikret, ve Servet Çetinkaya. “Comparison of Two Different Brands of Toric Intraocular Lens Implantation”. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi, c. 1, sy 3, Aralık 2020, ss. 7-13, https://izlik.org/JA92KU45MJ.
Vancouver
1.Fikret Ucar, Servet Çetinkaya. Comparison of Two Different Brands of Toric Intraocular Lens Implantation. KTOKUSB-D [Internet]. 01 Aralık 2020;1(3):7-13. Erişim adresi: https://izlik.org/JA92KU45MJ