Araştırma Makalesi

Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts

Cilt: 2 Sayı: 1 30 Mart 2018
PDF İndir
EN TR

Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts

Öz

This study pertains to the numerical investigation of the influence of V-nozzle turbulators on thermal performance in a circular tube under uniform heat flux condition. The converging-diverging nozzles as a venturi structure were located in the test tube in order to generate turbulance/reverseflow. The computations were carried out by consideration of various pitch ratios, PR = 2, 4, and 6 for Reynolds numbers between 5000 and 32000, using air as a working fluid. The variation of Nusselt number (Nu) and friction factor (f) versus Reynolds number (Re) were introduced for the obtained numerical results. The plain tube results were compared with the works available in literature for confirmation of the used numerical method. Consequently, the results demonstrated that the usage of V-nozzles at smaller pitch ratio yielded an increase in heat transfer rate and pressure loss.

Anahtar Kelimeler

Kaynakça

  1. Eimsa-ard, S. and Promvonge, P.(2006), “Experimental Investigation of Heat Transfer and Friction Characteristics in a Circular Tube Fitted with V-nozzle Turbulators”, Int Commun Heat Mass Transfer, (33), 591–600.
  2. [Shoji, Y., Sato, K., and Oliver D.R.(2003), “Heat Transfer Enhancement in Round Tube using Wire Coil Influence of Length and Segmentation”, Heat Transfer-Asian Res, (32), 99-107.
  3. Zimparov, V. (2001), “Enhancement of Heat Transfer by a Combination of Three-Start Spirally Corrugated Tubes with a Twisted Tape”, Int J Heat Mass Transfer,( 44), 551–574.
  4. Tandiroglu, A., and Ayhan, T.(2006), “Energy Dissipation Analysis of Transient Heat Transfer for Turbulent Flow in a Circular Tube with Baffle Inserts”, Appl Therm Eng, (26),178–185.
  5. Yakut, K., Alemdaroglu, N., Sahin, B.,and Celik, C.(2006), “Optimum Design Parameters of a Heat Exchanger Having Hexagonal Fins”, Appl Energy, (83), 82–98.
  6. Zhang, Z., Yu, Z. and Fang, X.(2007), “An Experimental Heat Transfer Study for Helically Flowing Outside Petal-Shaped Finned Tubes with Different Geometrical Parameters”, Appl Therm Eng, (27), 268–272.
  7. Tijing, L.D., Pak, B.C., Baek, B.J. and Lee, D.H.(2006), “A Study on Heat Transfer Enhancement Using Straight and Twisted Internal Fins”, Int Commun Heat Mass Transfer, (33), 719–726.
  8. Eimsa-ard, S., Thianpong, C. and Promvonge, P.(2006), “Experimental Investigation of Heat Transfer and Flow Friction in a Circular Tube Fitted with Regularly Spaced Twisted Tape Elements”, Int Commun Heat Mass Transfer, (33), 1225–1233.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Sibel Güneş
ERCİYES ÜNİVERSİTESİ
Türkiye

Orhan Keklikcioğlu
ERCİYES ÜNİVERSİTESİ
Türkiye

Toygun Dağdevir
ERCİYES ÜNİVERSİTESİ
Türkiye

Veysel Özceyhan
ERCİYES ÜNİVERSİTESİ
Türkiye

Yayımlanma Tarihi

30 Mart 2018

Gönderilme Tarihi

7 Kasım 2017

Kabul Tarihi

6 Aralık 2017

Yayımlandığı Sayı

Yıl 2018 Cilt: 2 Sayı: 1

Kaynak Göster

APA
Güneş, S., Keklikcioğlu, O., Dağdevir, T., & Özceyhan, V. (2018). Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi, 2(1), 42-54. https://doi.org/10.31200/makuubd.349798
AMA
1.Güneş S, Keklikcioğlu O, Dağdevir T, Özceyhan V. Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts. MAKÜUBD. 2018;2(1):42-54. doi:10.31200/makuubd.349798
Chicago
Güneş, Sibel, Orhan Keklikcioğlu, Toygun Dağdevir, ve Veysel Özceyhan. 2018. “Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2 (1): 42-54. https://doi.org/10.31200/makuubd.349798.
EndNote
Güneş S, Keklikcioğlu O, Dağdevir T, Özceyhan V (01 Mart 2018) Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2 1 42–54.
IEEE
[1]S. Güneş, O. Keklikcioğlu, T. Dağdevir, ve V. Özceyhan, “Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts”, MAKÜUBD, c. 2, sy 1, ss. 42–54, Mar. 2018, doi: 10.31200/makuubd.349798.
ISNAD
Güneş, Sibel - Keklikcioğlu, Orhan - Dağdevir, Toygun - Özceyhan, Veysel. “Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2/1 (01 Mart 2018): 42-54. https://doi.org/10.31200/makuubd.349798.
JAMA
1.Güneş S, Keklikcioğlu O, Dağdevir T, Özceyhan V. Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts. MAKÜUBD. 2018;2:42–54.
MLA
Güneş, Sibel, vd. “Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi, c. 2, sy 1, Mart 2018, ss. 42-54, doi:10.31200/makuubd.349798.
Vancouver
1.Sibel Güneş, Orhan Keklikcioğlu, Toygun Dağdevir, Veysel Özceyhan. Thermal Performance of a Tube Equipped with V-nozzle Turbulator Inserts. MAKÜUBD. 01 Mart 2018;2(1):42-54. doi:10.31200/makuubd.349798