Araştırma Makalesi

Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures

Cilt: 2 Sayı: 2 30 Eylül 2018
PDF İndir
EN TR

Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures

Öz

The heat pipe is an effective heat transfer device. Thermosyphon is a closed, vacuumed, fluid contained and generally pipe shaped heat transfer device. It ensures high heat transfer even at very low temperature differences. Heat pipes have very wide utilization fields. Therefore, many studies have been carried out to improve the thermal performances of heat pipes. In this study, the effect of the fluid charge rate on the operation of the heat pipe was examined. To do this, a heat pipe model with a diameter of 25 mm was created. The heat pipe's evaporator, condenser and adiabatic lengths are 2m, 1m and 0.1m respectively. The heat pipe has been examined for various fluid charge rates and different heat source temperatures. The increase in fluid charge rate has been seen to have a negative impact on the operation of the heat pipe, particularly at low temperatures. In addition, at low temperatures the acetone performed better heat transfer than the methanol. At high temperatures, the methanol performed better heat transfer than the acetone.

Anahtar Kelimeler

Kaynakça

  1. REFERENCESBezrodnyı, M. K., Alekseenko, D. B., (1977). Investigation of the critical region of heat and mass transfer in low-temperature wickless heat pipes. High Temperature, 15,309-313.
  2. Çengel, Y. A., (2011). Isı ve kütle transferi. Güven Kitabevi, 879s, İzmir.
  3. ESDU 80017 (2005). Thermophysical properties of heat pipe working fluids: Operating range between 60 °C and 300 °C. ESDU, 2005-2. London.
  4. ESDU 81038., (2005). Heat pipes performance of two-phase closed thermosyphons. ESDU, 2005-2, London.
  5. Faghri A., (1995). Heat Pipe Science and Technology. Taylor and Francis, 874p. London.
  6. Genceli, F. O., (2010). Isı değiştiricileri. Birsen yayınevi, 421s, İstanbul.
  7. Joudi, K., Witvit, A., (1993). Improvements of gravity assisted wickless heat pipes. Energy Conversion Management, 41, 2041–2061.
  8. Nguyen-chi, H., Groll, M., (1981). Entrainment or flooding limit in a closed two-phase thermosyphon. Advances in Heat Pipe Technology: IV International Heat Pipe Conference, London, September 1981. Pergamon Press, Oxford, 1982.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Eylül 2018

Gönderilme Tarihi

27 Temmuz 2018

Kabul Tarihi

8 Ağustos 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 2 Sayı: 2

Kaynak Göster

APA
Yıldırım, R., Yıldız, A., & Özsoy, A. (2018). Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi, 2(2), 52-67. https://doi.org/10.31200/makuubd.448587
AMA
1.Yıldırım R, Yıldız A, Özsoy A. Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures. MAKÜUBD. 2018;2(2):52-67. doi:10.31200/makuubd.448587
Chicago
Yıldırım, Ragıp, Abdullah Yıldız, ve Ahmet Özsoy. 2018. “Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2 (2): 52-67. https://doi.org/10.31200/makuubd.448587.
EndNote
Yıldırım R, Yıldız A, Özsoy A (01 Eylül 2018) Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2 2 52–67.
IEEE
[1]R. Yıldırım, A. Yıldız, ve A. Özsoy, “Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures”, MAKÜUBD, c. 2, sy 2, ss. 52–67, Eyl. 2018, doi: 10.31200/makuubd.448587.
ISNAD
Yıldırım, Ragıp - Yıldız, Abdullah - Özsoy, Ahmet. “Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi 2/2 (01 Eylül 2018): 52-67. https://doi.org/10.31200/makuubd.448587.
JAMA
1.Yıldırım R, Yıldız A, Özsoy A. Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures. MAKÜUBD. 2018;2:52–67.
MLA
Yıldırım, Ragıp, vd. “Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures”. Mehmet Akif Ersoy Üniversitesi Uygulamalı Bilimler Dergisi, c. 2, sy 2, Eylül 2018, ss. 52-67, doi:10.31200/makuubd.448587.
Vancouver
1.Ragıp Yıldırım, Abdullah Yıldız, Ahmet Özsoy. Influence of Fluid Charge Rate on Gravity Assisted Heat Pipe Performance at Low Temperatures. MAKÜUBD. 01 Eylül 2018;2(2):52-67. doi:10.31200/makuubd.448587