Öz

The electro anatomy of the cochlea plays a crucial role in hearing, where damage to the cochlea may cause hearing loss. Cochlear neuromodulators provide hearing to severe or profound hearing-impaired individuals. The accurate insertion of electrodes into the cochlea is an important factor. If misplaced it may lead to further damage (insertion trauma). Visual inspection of the electrode insertion is limited and relies on the experience of the surgeon. Assisted real time guidance in positioning the electrode array in the cochlea during insertion is needed. Its position can be identified based on the variation in the impedances of electrodes which can be rapidly assessed and interpreted. Using an advanced computational model of the cochlea which accounted for different tissue layers in the cochlea, impedance variations and electrical potentials at different electrode distances from the cochlear wall were simulated, which suggest that the variations in impedance can be used to detect the proximity of the electrodes to the cochlea wall.

Anahtar Kelimeler

Kaynakça

  1. A. Dhanasingh and C. Jolly, “An overview of cochlear implant electrode array designs,” Hear.Res., vol. 356, pp. 93–103, 2017.
  2. K. Dang, “Electrical conduction models for cochlear implant stimulation,” 2017.
  3. L. K. Holden et al., “Factors affecting open-set word recognition in adults with cochlear implants,” vol. 34, no. 3, pp. 342–360, 2014.
  4. K. S. Min, S. B. Jun, Y. S. Lim, S. I. Park, and S. J. Kim, “Modiolus-hugging intracochlear electrode array with shape memory alloy,” Comput. Math. Methods Med., vol. 2013, 2013.
  5. T. H. and J. J. H. T. K. Malherbe, “Constructing a three- dimensional electrical model of a living cochlear implant user’s cochlea,” Training, vol. 4179, no. December 2015, p. 53, 2016.
  6. J. H. M. Frijns, J. J. Briaire, and J. J. Grote, “The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants,” Otol. Neurotol., vol. 22, no. 3, pp. 340–349, 2001.
  7. C. K. Giardina, E. S. Krause, K. Koka, and D. C. Fitzpatrick, “Impedance measures during invitro cochlear implantation predict array positioning,” IEEE Trans. Biomed. Eng., vol. 65, no. 2, pp. 327–335, 2018.
  8. E. Salkim, A. Shiraz, and A. Demosthenous, “Impact of neuroanatomical variations and electrode orientation on stimulus current in a device for migraine: a computational study,” JNeural Eng., vol. 17, no. 1, p. 016006, 2019.

Ayrıntılar

Birincil Dil

Türkçe

Konular

Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Yazarlar

Enver Salkım * Bu kişi benim
Türkiye

Yayımlanma Tarihi

27 Aralık 2020

Gönderilme Tarihi

17 Aralık 2020

Kabul Tarihi

21 Aralık 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 1 Sayı: 1

Kaynak Göster

APA
Salkım, E. (2020). Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, 1(1), 64-71. https://izlik.org/JA34HJ36TF
AMA
1.Salkım E. Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi. 2020;1(1):64-71. https://izlik.org/JA34HJ36TF
Chicago
Salkım, Enver. 2020. “Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study”. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 1 (1): 64-71. https://izlik.org/JA34HJ36TF.
EndNote
Salkım E (01 Aralık 2020) Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 1 1 64–71.
IEEE
[1]E. Salkım, “Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study”, Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, c. 1, sy 1, ss. 64–71, Ara. 2020, [çevrimiçi]. Erişim adresi: https://izlik.org/JA34HJ36TF
ISNAD
Salkım, Enver. “Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study”. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 1/1 (01 Aralık 2020): 64-71. https://izlik.org/JA34HJ36TF.
JAMA
1.Salkım E. Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi. 2020;1:64–71.
MLA
Salkım, Enver. “Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study”. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, c. 1, sy 1, Aralık 2020, ss. 64-71, https://izlik.org/JA34HJ36TF.
Vancouver
1.Enver Salkım. Electrode Array Position Guiding in Cochlea Based on Impedance Variation: Computational Study. Muş Alparslan Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi [Internet]. 01 Aralık 2020;1(1):64-71. Erişim adresi: https://izlik.org/JA34HJ36TF