In this study, the exergy efficiency analysis of organic Rankine cycle (ORC) was carried out. R123 and SES 36 were used in
system as refrigerants. The necessary thermodynamic values for analyses were calculated by Solkane program. The exergy
efficiency rate of the system in the different operating conditions were investigated for these refrigerants. As a result, the
highest exergy efficiency rate of the organic Rankine cycle (ORC) was obtained for 40 oC the condenser temperature, 60 oC
for stream generator temperature and 0.6916 kg/s for mass flow and about %35 for exergy efficiency.

Organik Rankine Çevriminin Ekserji Verimi Analizi

Yıl 2017, Cilt: 6 Sayı: 1, 0 - 0, 01.03.2017

Öz

Bu çalışmada, organik rankine çevriminin ekserji verimi analizi yapılmıştır. Sistemde soğutucu akışkan olarak R123 ve SES 36
kullanılmıştır. Analiz için gerekli termodinamik değerler Solkane programıyla hesaplanmıştır. Bu soğutucu akışkanlar için
farklı çalışma şartlarında sistemin ekserji verimi oranı incelenmiştir. Sonuç olarak, organik rankine çevriminin en yüksek
ekserji verimi oranı, 40 oC kondenser sıcaklığı, 60 oC buhar jeneratörü sıcaklığı ve 0.6916 kg/s akışkan debisi için yaklaşık %35
olarak elde edilmiştir.