Klinik Araştırma

Evaluation of the Temperature Values in the Use of Different Types of Burs

Cilt: 5 Sayı: 2 15 Mayıs 2023
PDF İndir
TR EN

Evaluation of the Temperature Values in the Use of Different Types of Burs

Öz

Aim: In our study, we aimed to measure the amount of released head by recording it with a thermal camera during the osteotomies made utilizing round, fissure and lindemann burs to the synthetic bone blocks to simulate the mandible ramus region which is often preferred when obtaining autogenous bone from the mouth. Material and Methods: The burs in our study were used at rotational speeds of 10000 rpm and 15000 rpm and feed rates of 60 mm/min and 90 mm/min, and each osteotomy was made with a CNC milling machine in order to standardize the applied force. Results: According to the results of our study, the highest temperatures were observed in the fissure bur groups, and the round bur and lindemann bur groups gave similar results. In addition, when the feed rate is increased from 60 mm/min to 90 mm/min in all groups at constant rotational speed, the heat released increases significantly. When the groups are evaluated within themselves; the temperature values observed at 15000 rpm and 60 mm/min feed rate in the groups using round bur were found to be significantly lower than the group observed at 10000 rpm and 60 mm/min feed rates (p=0.028), in fissure bur groups, the temperature values observed at 10000 rpm and 60 mm/min feed rate were significantly lower than the values observed at 15000 rpm and 60 mm/min feed rates (p=0.028). No statistically significant difference was observed between the heat exchange averages of the 10000 rpm and 15000 rpm groups at a Lindemann bur 60 mm/min feed rate (p=0.182). Conclusion: This study has shown that while the generated heat in the bone is thought to increase when the bur speeds are increased, the head generated according to bur designs can decrease and it is necessary to operate according to the characteristic features of the preferred bur.

Anahtar Kelimeler

Kaynakça

  1. Szalma J, Lovasz BV, Vajta L, et al. The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times. Sci Rep. 2019;9:11817.
  2. Crowninshield RD, Pope MH. The response of compact bone in tension at various strain rates. Ann Biomed Eng. 1974;2:217–25.
  3. Feldmann A, Wili P, Maquer G, Zysset P. The thermal conductivity of cortical and cancellous bone. Eur Cells Mater. 2018;35:25–33.
  4. Soriano J, Garay A, Aristimuno P, Arrazola PJ. Study and improvement of surgical drill bit geometry for implant site preparation. Int J Adv Manuf Technol. 2014;74:615–27.
  5. Davidson SR, James DF. Measurement of thermal conductivity of bovine cortical bone. Med Eng Phys. 2000;22:741–7.
  6. Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50:101–7.
  7. Augustin G, Zigman T, Davila S, et al. Cortical bone drilling and thermal osteonecrosis. Clin Biomech Bristol Avon. 2012;27:313–25.
  8. Pandey RK, Panda SS. Drilling of bone: a comprehensive review. J Clin Orthop Trauma. 2013;4:15–30.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Cerrahi

Bölüm

Klinik Araştırma

Erken Görünüm Tarihi

15 Mayıs 2023

Yayımlanma Tarihi

15 Mayıs 2023

Gönderilme Tarihi

8 Şubat 2023

Kabul Tarihi

13 Mart 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 5 Sayı: 2

Kaynak Göster

APA
Ayhan, M. (2023). Evaluation of the Temperature Values in the Use of Different Types of Burs. Medical Records, 5(2), 342-8. https://doi.org/10.37990/medr.1249118
AMA
1.Ayhan M. Evaluation of the Temperature Values in the Use of Different Types of Burs. Med Records. 2023;5(2):342-8. doi:10.37990/medr.1249118
Chicago
Ayhan, Mustafa. 2023. “Evaluation of the Temperature Values in the Use of Different Types of Burs”. Medical Records 5 (2): 342-8. https://doi.org/10.37990/medr.1249118.
EndNote
Ayhan M (01 Mayıs 2023) Evaluation of the Temperature Values in the Use of Different Types of Burs. Medical Records 5 2 342–8.
IEEE
[1]M. Ayhan, “Evaluation of the Temperature Values in the Use of Different Types of Burs”, Med Records, c. 5, sy 2, ss. 342–8, May. 2023, doi: 10.37990/medr.1249118.
ISNAD
Ayhan, Mustafa. “Evaluation of the Temperature Values in the Use of Different Types of Burs”. Medical Records 5/2 (01 Mayıs 2023): 342-8. https://doi.org/10.37990/medr.1249118.
JAMA
1.Ayhan M. Evaluation of the Temperature Values in the Use of Different Types of Burs. Med Records. 2023;5:342–8.
MLA
Ayhan, Mustafa. “Evaluation of the Temperature Values in the Use of Different Types of Burs”. Medical Records, c. 5, sy 2, Mayıs 2023, ss. 342-8, doi:10.37990/medr.1249118.
Vancouver
1.Mustafa Ayhan. Evaluation of the Temperature Values in the Use of Different Types of Burs. Med Records. 01 Mayıs 2023;5(2):342-8. doi:10.37990/medr.1249118