Objective: In this study, randomized clinical trial (RCT), the aim was to compare clinical periodontal data of subepithelial connective tissue graft (SCTG) group and SCGT+enamel matrix derivatives (EMD) group in terms of gained gingiva volume (GGV) and gained gingiva surface area (GGSA) by scanners of computer-aided design/computer-aided manufacturing (CAD/CAM) devices.

Material and Methods: In this study, a total of 35 Miller class I-II gingival recession defects were involved (n=17 in SCTG group, n=18 in SCTG+EMD group). In addition to, periodontal clinical parameters, and  three dimensional (3D) images were recorded by using CAD/CAM system before the treatment, at the 1st month and the 6th months after the treatment. The images were superimposed by using softwares and GGV, and GGSA were calculated.

Results: There was no significant difference in terms of GGV and GGSA values at the 1st month and 6th months between SCTG+EMD and SCTG groups. Similarly, there was no  significant difference in periodontal clinical parameters between groups.

Conclusion: Images obtained from CAD/CAM system can be easily used in calculating GGV and GGSA data after the gingival recession treatment and in determining of the success of administered treatment. It is expected that the evaluation of the success of many therapeutic approaches for periodontal treatment will be carried out by using CAD/CAM system in the future.

Keywords

Kaynakça

  1. 1. Köseoğlu S, Sağlam M, Pekbağrıyanık T, Savran L, Sütçü R. Level of Interleukin-35 in Gingival Crevicular Fluid, Saliva, and Plasma in Periodontal Disease and Health. J Periodontol [Internet]. 2015 Aug [cited 2017 Jan 15];86(8):964–71. Available from: http://www.ncbi.nlm.nih.gov/pubmed/25786564
  2. 2. Valderhaug J. Periodontal conditions and carious lesions following the insertion of fixed prostheses: a 10-year follow-up study. Int Dent J [Internet]. 1980 Dec [cited 2017 Aug 16];30(4):296–304. Available from: http://www.ncbi.nlm.nih.gov/pubmed/6935162
  3. 3. Goldstein M, Nasatzky E, Goultschin J, Boyan BD, Schwartz Z. Coverage of Previously Carious Roots Is as Predictable a Procedure as Coverage of Intact Roots. J Periodontol [Internet]. 2002 Dec [cited 2017 Aug 16];73(12):1419–26. Available from: http://www.ncbi.nlm.nih.gov/pubmed/12546091
  4. 4. Silva RC Da, Joly JC, de Lima AFM, Tatakis DN. Root Coverage Using the Coronally Positioned Flap With or Without a Subepithelial Connective Tissue Graft. J Periodontol [Internet]. 2004 Mar [cited 2017 Aug 16];75(3):413–9. Available from: http://www.ncbi.nlm.nih.gov/pubmed/15088880
  5. 5. Sculean A, Windisch P, Keglevich T, Gera I. Histologic evaluation of human intrabony defects following non-surgical periodontal therapy with and without application of enamel matrix derivatives. J Periodontol. 2003;74:153–60.
  6. 6. Ronay V, Sahrmann P, Bindl A, Attin T, Schmidlin PR. Current Status and Perspectives of Mucogingival Soft Tissue Measurement Methods. J Esthet Restor Dent [Internet]. 2011 Jun [cited 2016 Dec 4];23(3):146–56. Available from: http://www.ncbi.nlm.nih.gov/pubmed/21649828
  7. 7. Weinländer M, Lekovic V, Spadijer-Gostovic S, Milicic B, Krennmair G, Plenk Jr H. Gingivomorphometry - esthetic evaluation of the crown-mucogingival complex: a new method for collection and measurement of standardized and reproducible data in oral photography. Clin Oral Implants Res [Internet]. 2009 May [cited 2017 Aug 16];20(5):526–30. Available from: http://www.ncbi.nlm.nih.gov/pubmed/19522978
  8. 8. Rosin M, Splieth C, Hessler M, Gärtner C, Kordass B, Kocher T. Quantification of gingival edema using a new 3-D laser scanning method. J Clin Periodontol [Internet]. 2002 Mar [cited 2016 Dec 4];29(3):240–6. Available from: http://www.ncbi.nlm.nih.gov/pubmed/11940144

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Hacer Sahin Aydinyurt
Yüzüncü Yil University, Dentistry Faculty, Van
Türkiye

Abdullah Seckin Ertugrul
Izmir Katip Celebi University, Dentistry Faculty, Izmir
Türkiye

Yayımlanma Tarihi

30 Ekim 2017

Gönderilme Tarihi

5 Ekim 2017

Kabul Tarihi

11 Ekim 2017

Yayımlandığı Sayı

Yıl 1970 Cilt: 4 Sayı: 10

Kaynak Göster

APA
Sahin Aydinyurt, H., & Ertugrul, A. S. (2017). A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Medical Science and Discovery, 4(10), 72-79. https://doi.org/10.17546/msd.341826
AMA
1.Sahin Aydinyurt H, Ertugrul AS. A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Med Sci Discov. 2017;4(10):72-79. doi:10.17546/msd.341826
Chicago
Sahin Aydinyurt, Hacer, ve Abdullah Seckin Ertugrul. 2017. “A novel volumetric analysis using cad/cam scanners in gingival recession treatment”. Medical Science and Discovery 4 (10): 72-79. https://doi.org/10.17546/msd.341826.
EndNote
Sahin Aydinyurt H, Ertugrul AS (01 Ekim 2017) A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Medical Science and Discovery 4 10 72–79.
IEEE
[1]H. Sahin Aydinyurt ve A. S. Ertugrul, “A novel volumetric analysis using cad/cam scanners in gingival recession treatment”, Med Sci Discov, c. 4, sy 10, ss. 72–79, Eki. 2017, doi: 10.17546/msd.341826.
ISNAD
Sahin Aydinyurt, Hacer - Ertugrul, Abdullah Seckin. “A novel volumetric analysis using cad/cam scanners in gingival recession treatment”. Medical Science and Discovery 4/10 (01 Ekim 2017): 72-79. https://doi.org/10.17546/msd.341826.
JAMA
1.Sahin Aydinyurt H, Ertugrul AS. A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Med Sci Discov. 2017;4:72–79.
MLA
Sahin Aydinyurt, Hacer, ve Abdullah Seckin Ertugrul. “A novel volumetric analysis using cad/cam scanners in gingival recession treatment”. Medical Science and Discovery, c. 4, sy 10, Ekim 2017, ss. 72-79, doi:10.17546/msd.341826.
Vancouver
1.Hacer Sahin Aydinyurt, Abdullah Seckin Ertugrul. A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Med Sci Discov. 01 Ekim 2017;4(10):72-9. doi:10.17546/msd.341826

Cited By