BibTex RIS Kaynak Göster

Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients

Yıl 2014, Cilt: 1 Sayı: 2, 31 - 34, 01.06.2014

Öz

Aim: Ultrasound (USG)-guided hemodialysis catheter placement is known to be superior to and more reliable than catheter insertion guided by anatomical landmarks. USG is used for vascular mapping (VM) before catheter placement, or real time. This study investigated the effect on outcomes of USG techniques used in patients with hemodialysis catheters inserted through the internal jugular vein (IJV) due to emergency hemodialysis indication while being monitored for Predialysis Renal Failure (PRF). Material and Methods: Fifty-nine patients with PRF undergoing USG-guided hemodialysis catheter placement between January 2012 and May 2014 at the Balikesir University Health Practice and Research Hospital were evaluated retrospectively. Results: Twenty-eight patients were male and 31 female. The right IJV was used in 57 patients and the left IJV in two. Success rate at first attempt in real time USG group was 91.3% (21/23), compared to 91.6% (34/36) in the VM group. Average number of puncture was similar (1.08±0.291 vs. 1.16±0.56). No complications occurred in either group. Discussion: Use of USG in real time and for VM in patients with PRF gives similar results in terms of success and complication rates. We therefore recommend that USG only for vascular mapping be used solely in these patients in order to avoid time loss and increased costs.

Kaynakça

  • Akoglu H, Piskinpasa S, Yenigun EC, Ozturk R, Dede F, Odabas
  • AR. Real-time ultrasound guided placement of temporary internal jugular vein catheters: assessment of technical success and complication rates in nephrology practice. Nephrology. 2012;17(7):603-6.
  • Copyright © 2014 The Author(s); This is an open-access article distributed under the terms of the Creative Commons
  • Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and
  • reproduction in any medium, provided the original work is properly cited.

Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients

Yıl 2014, Cilt: 1 Sayı: 2, 31 - 34, 01.06.2014

Öz

Kaynakça

  • Akoglu H, Piskinpasa S, Yenigun EC, Ozturk R, Dede F, Odabas
  • AR. Real-time ultrasound guided placement of temporary internal jugular vein catheters: assessment of technical success and complication rates in nephrology practice. Nephrology. 2012;17(7):603-6.
  • Copyright © 2014 The Author(s); This is an open-access article distributed under the terms of the Creative Commons
  • Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and
  • reproduction in any medium, provided the original work is properly cited.
Toplam 5 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Araştırma Makalesi
Yazarlar

Murat Yildar Bu kişi benim

Orcun Gurbuz Bu kişi benim

Gencehan Kumtepe Bu kişi benim

Murat Basbug Bu kişi benim

Omer Toprak Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 1 Sayı: 2

Kaynak Göster

APA Yildar, M., Gurbuz, O., Kumtepe, G., Basbug, M., vd. (2014). Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients. Medical Science and Discovery, 1(2), 31-34. https://doi.org/10.17546/msd.13732
AMA Yildar M, Gurbuz O, Kumtepe G, Basbug M, Toprak O. Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients. Med Sci Discov. Haziran 2014;1(2):31-34. doi:10.17546/msd.13732
Chicago Yildar, Murat, Orcun Gurbuz, Gencehan Kumtepe, Murat Basbug, ve Omer Toprak. “Ultrasound-Guided Cannulation in Placement of Hemodialysis Access Catheters in Predialysis Patients”. Medical Science and Discovery 1, sy. 2 (Haziran 2014): 31-34. https://doi.org/10.17546/msd.13732.
EndNote Yildar M, Gurbuz O, Kumtepe G, Basbug M, Toprak O (01 Haziran 2014) Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients. Medical Science and Discovery 1 2 31–34.
IEEE M. Yildar, O. Gurbuz, G. Kumtepe, M. Basbug, ve O. Toprak, “Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients”, Med Sci Discov, c. 1, sy. 2, ss. 31–34, 2014, doi: 10.17546/msd.13732.
ISNAD Yildar, Murat vd. “Ultrasound-Guided Cannulation in Placement of Hemodialysis Access Catheters in Predialysis Patients”. Medical Science and Discovery 1/2 (Haziran 2014), 31-34. https://doi.org/10.17546/msd.13732.
JAMA Yildar M, Gurbuz O, Kumtepe G, Basbug M, Toprak O. Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients. Med Sci Discov. 2014;1:31–34.
MLA Yildar, Murat vd. “Ultrasound-Guided Cannulation in Placement of Hemodialysis Access Catheters in Predialysis Patients”. Medical Science and Discovery, c. 1, sy. 2, 2014, ss. 31-34, doi:10.17546/msd.13732.
Vancouver Yildar M, Gurbuz O, Kumtepe G, Basbug M, Toprak O. Ultrasound-guided cannulation in placement of Hemodialysis Access Catheters in Predialysis Patients. Med Sci Discov. 2014;1(2):31-4.