THE CONTROL OF A DC MOTOR BY FUZZY LOGIC CONTROLLER

Yıl 2011, Cilt: 6 Sayı: 2, 533 - 541, 01.03.2011
https://izlik.org/JA29CA46KY

Öz

HAVING DONE THIS STUDY, DIRECT CURRENT (DC) MOTOR WAS CONTROLLED BY FUZZY LOGIC CONTROLLER (FLC). SINCE THE STUDY INCLUDED ANALYSIS AND PERFORMANCE INCREASE, SIMULATION WAS IMPLEMENTED IN MATLAB/SIMULINK ENVIRONMENT. THE INPUTS OF THE FLC WERE ERROR AND CHANGE IN ERROR WHEREAS OUTPUT OF FLC WAS ELECTRICAL ENGINE VOLTAGE. IT HAS BEEN SEEN THAT FLC IS MUCH MORE SUCCESSFUL THAN PID CONTROL ACCORDING TO THE COMPARISON MADE BETWEEN OUTPUTS OF PID AND FLC CONTROL.

BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ

Yıl 2011, Cilt: 6 Sayı: 2, 533 - 541, 01.03.2011
https://izlik.org/JA29CA46KY

Öz

BU ÇALI?MADA BYR DO?RU AKIM (DA) MOTORUNUN BULANIK MANTIK DENETLEYYCY (BMD) KONTROLÜ ELE ALINMI?TIR. BU ÇALI?MA YAPILIRKEN, ANALYZ ÇALI?MALARI VE PERFORMANS ARTTIRICI ÇALI?MALARA YMKAN VERMESY NEDENYYLE BENZETYM MATLAB/SYMULYNK ORTAMINDA GERÇEKLENMY?TYR. ÇALI?MADA DA MOTOR HIZINI DENETLEMEK ÜZERE OLU?TURULAN BMD YÇYN DURUM DE?Y?KENLERY OLARAK HATA VE HATA DE?Y?YMY KULLANILMI? MOTOR VOLTAJI ÇIKTI OLARAK KABUL EDYLMY?TYR. ELDE EDYLEN BULANIK MANTIK DENETLEYYCY ÇIKTISI, PID KONTROL ÇIKTISI YLE KAR?ILA?TIRILARAK YNCELENMY?TYR.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Yazarlar

İsmail Sarıtaş Bu kişi benim

İlker Ali Ozkan Bu kişi benim

Saadetdin Herdem Bu kişi benim

Yayımlanma Tarihi 1 Mart 2011
DOI https://doi.org/10.12739/nwsaes.v6i2.5000066990
IZ https://izlik.org/JA29CA46KY
Yayımlandığı Sayı Yıl 2011 Cilt: 6 Sayı: 2

Kaynak Göster

APA Sarıtaş, İ., Ozkan, İ. A., & Herdem, S. (2011). BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ. Engineering Sciences, 6(2), 533-541. https://doi.org/10.12739/nwsaes.v6i2.5000066990
AMA 1.Sarıtaş İ, Ozkan İA, Herdem S. BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ. Engineering Sciences. 2011;6(2):533-541. doi:10.12739/nwsaes.v6i2.5000066990
Chicago Sarıtaş, İsmail, İlker Ali Ozkan, ve Saadetdin Herdem. 2011. “BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ”. Engineering Sciences 6 (2): 533-41. https://doi.org/10.12739/nwsaes.v6i2.5000066990.
EndNote Sarıtaş İ, Ozkan İA, Herdem S (01 Mart 2011) BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ. Engineering Sciences 6 2 533–541.
IEEE [1]İ. Sarıtaş, İ. A. Ozkan, ve S. Herdem, “BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ”, Engineering Sciences, c. 6, sy 2, ss. 533–541, Mar. 2011, doi: 10.12739/nwsaes.v6i2.5000066990.
ISNAD Sarıtaş, İsmail - Ozkan, İlker Ali - Herdem, Saadetdin. “BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ”. Engineering Sciences 6/2 (01 Mart 2011): 533-541. https://doi.org/10.12739/nwsaes.v6i2.5000066990.
JAMA 1.Sarıtaş İ, Ozkan İA, Herdem S. BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ. Engineering Sciences. 2011;6:533–541.
MLA Sarıtaş, İsmail, vd. “BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ”. Engineering Sciences, c. 6, sy 2, Mart 2011, ss. 533-41, doi:10.12739/nwsaes.v6i2.5000066990.
Vancouver 1.İsmail Sarıtaş, İlker Ali Ozkan, Saadetdin Herdem. BYR DC MOTORUN BULANIK MANTIK DENETLEYYCY YLE KONTROLÜ. Engineering Sciences. 01 Mart 2011;6(2):533-41. doi:10.12739/nwsaes.v6i2.5000066990