BibTex RIS Kaynak Göster

MONTE CARLO SYMULATION CHARACTERISTICS OF MODEL 6711 BRACHYTHERAPY SEED: EFFECTS OF ENERGY SPECTRUM AND PHANTOM DIMENSIONS

Yıl 2010, Cilt: 5 Sayı: 2, 283 - 292, 01.03.2010

Öz

It is important to determine specified dose distributions of radioactive seed sources of brachytherapy in both phantom material and treated tissues. Dosimetric features and specific dose distribution functions of Model 6711 brachytherapy seed which is frequently used in prostate cancer treatments, have been given in literature. In the present study decay spectrum of radioactive material and variations of phantom dimensions which are foreseen to affect dosimetric specifications of the seed, were investigated and results were performed by Monte Carlo simulation. In simulation using separate decay spectrum and mono energy, differences were noted between interval of 1-68 percent. Also in calculations of phantom dimensions variations, deviations were not observed more than 0.1 percent by normalization to 1 as expected.

MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY

Yıl 2010, Cilt: 5 Sayı: 2, 283 - 292, 01.03.2010

Öz

Brakiterapide kullanylan radyoaktif kaynaklaryn gerek doku içerisinde gerekse fantom metaryelindeki özelle?mi? doz da?ylymlarynyn hassas olarak bilinmesi tedavi planlamalarynda önemlidir. Prostat kanseri tedavisinde syklykla tercih edilen Model 6711 kayna?ynyn dozimetrik özellikleri ve ilgili doz da?ylymlaryny ifade eden fonksiyonlary literatürde verilmi? durumdadyr. Bu çaly?mada bu kayna?a özel parametreleri etkileyece?i öngörülen, radyoaktif malzemenin bozunum spektrumu ve kullanylan simülasyon fantomunun büyüklü?üne ait de?i?imler incelenerek etkileri Monte Carlo simulasyonu kullanylarak ortaya konmu?tur. Bozunum spektrumu ve tek enerji kullanylarak yapylan çaly?malarda parametreler arasynda %1 ile %68 orasnynda de?i?en farklar görülmü?tür. Fantom geni?liklerinin de?i?iminden kaynaklanan hesaplarda parametrelerin bire normalizasyonlarynda beklendi?i gibi %0,1 den büyük farklar gözlenmemi?tir.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Bilgisayar Mühendisliği
Yazarlar

Berkay Camgoz Bu kişi benim

Mehmet N. Kumru Bu kişi benim

Yayımlanma Tarihi 1 Mart 2010
Yayımlandığı Sayı Yıl 2010 Cilt: 5 Sayı: 2

Kaynak Göster

APA Camgoz, B., & Kumru, M. N. (2010). MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY. Engineering Sciences, 5(2), 283-292. https://doi.org/10.12739/nwsaes.v5i2.5000067092
AMA Camgoz B, Kumru MN. MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY. Engineering Sciences. Mart 2010;5(2):283-292. doi:10.12739/nwsaes.v5i2.5000067092
Chicago Camgoz, Berkay, ve Mehmet N. Kumru. “MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY”. Engineering Sciences 5, sy. 2 (Mart 2010): 283-92. https://doi.org/10.12739/nwsaes.v5i2.5000067092.
EndNote Camgoz B, Kumru MN (01 Mart 2010) MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY. Engineering Sciences 5 2 283–292.
IEEE B. Camgoz ve M. N. Kumru, “MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY”, Engineering Sciences, c. 5, sy. 2, ss. 283–292, 2010, doi: 10.12739/nwsaes.v5i2.5000067092.
ISNAD Camgoz, Berkay - Kumru, Mehmet N. “MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY”. Engineering Sciences 5/2 (Mart 2010), 283-292. https://doi.org/10.12739/nwsaes.v5i2.5000067092.
JAMA Camgoz B, Kumru MN. MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY. Engineering Sciences. 2010;5:283–292.
MLA Camgoz, Berkay ve Mehmet N. Kumru. “MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY”. Engineering Sciences, c. 5, sy. 2, 2010, ss. 283-92, doi:10.12739/nwsaes.v5i2.5000067092.
Vancouver Camgoz B, Kumru MN. MODEL 6711 BRAKYTERAPY KAYNA?ININ MONTE CARLO SYMÜLASYONU KARAKTERYSTYKLERY: ENERJY SPEKTRUMU VE FANTOM BÜYÜKLÜ?ÜNÜN ETKYLERY. Engineering Sciences. 2010;5(2):283-92.