THE EFFECTS OF VARIABLE AIR FLOW RATES ON THE SYSTEM PERFORMANCE WITHIN THE THERMOELECTRICAL MODULLED WATER COOLER

Yıl 2010, Cilt: 5 Sayı: 2, 131 - 143, 01.03.2010
https://izlik.org/JA48FC35EJ

Öz

In this study, 1 kg water which is filled in the 1.5 liter volume container has been cooled by using in the size 40x40x3.8mm with the code TEC-12706 thermoelectrical module. The other fins of the module surface has been cooled by three variable air flow rate and it has been investigated that its performance effect on the system. Although high air flow rate increase of the module performance, it has reduced total performance of system because it has consumed more than necessary fan power.

TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY

Yıl 2010, Cilt: 5 Sayı: 2, 131 - 143, 01.03.2010
https://izlik.org/JA48FC35EJ

Öz

Bu çaly?mada, 1.5 litre hacmindeki hazne içerisine doldurulan 1 kg su, 40 x 40 x 3.8 mm boyutunda TEC–12706 kodlu termoelektrik modül vasytasyyla so?utulmu?tur. Modülün di?er yüzeyindeki kanatçyklary üç farkly hava debisi ile so?utularak sistem performansyna etkisi incelenmi?tir. Yüksek hava debisi, modülün performansyny arttyrmasyna ra?men daha fazla fan gücü harcanmasyna neden oldu?undan sistemin toplam performansyny dü?ürmektedir.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Yazarlar

Celil Yavuz Bu kişi benim

Metin Kaya Bu kişi benim

Mehmet Özkaymak Bu kişi benim

Yayımlanma Tarihi 1 Mart 2010
DOI https://doi.org/10.12739/10.12739
IZ https://izlik.org/JA48FC35EJ
Yayımlandığı Sayı Yıl 2010 Cilt: 5 Sayı: 2

Kaynak Göster

APA Yavuz, C., Kaya, M., & Özkaymak, M. (2010). TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences, 5(2), 131-143. https://doi.org/10.12739/10.12739
AMA 1.Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences. 2010;5(2):131-143. doi:10.12739/10.12739
Chicago Yavuz, Celil, Metin Kaya, ve Mehmet Özkaymak. 2010. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences 5 (2): 131-43. https://doi.org/10.12739/10.12739.
EndNote Yavuz C, Kaya M, Özkaymak M (01 Mart 2010) TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences 5 2 131–143.
IEEE [1]C. Yavuz, M. Kaya, ve M. Özkaymak, “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”, Technological Applied Sciences, c. 5, sy 2, ss. 131–143, Mar. 2010, doi: 10.12739/10.12739.
ISNAD Yavuz, Celil - Kaya, Metin - Özkaymak, Mehmet. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences 5/2 (01 Mart 2010): 131-143. https://doi.org/10.12739/10.12739.
JAMA 1.Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences. 2010;5:131–143.
MLA Yavuz, Celil, vd. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences, c. 5, sy 2, Mart 2010, ss. 131-43, doi:10.12739/10.12739.
Vancouver 1.Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences [Internet]. 01 Mart 2010;5(2):131-43. Erişim adresi: https://izlik.org/JA48FC35EJ