Araştırma Makalesi
BibTex RIS Kaynak Göster

CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200

Yıl 2018, Cilt: 30 Sayı: 1, 1 - 6, 26.06.2018

Öz

Natural disaster occurred at Japan Fukushima Daiichi
NPP in March 2011 showed that combination of natural disasters with a long term
black out which is not accepted as a design basis accident till that day could
be how dangerous. In this study case, inventory calculation in the spent fuel
pool, transmission from inventory to source term and atmospheric dispersion
calculation of source term were investigated, in a case of long term black out
accident that can occur in the AES 2006 design VVER-1200 type of NPP planned to
be built in Turkey.

Kaynakça

  • [1] Oak Ridge National Laboratory (2002), ORIGEN-ARP: Isotope Generation and Depletion Code, Oak Ridge, Tennessee: Oak Ridge National Laboratory.
  • [2] Akkuyu Nükleer A.Ş. (2014), Environmental Impact Assessment Report of Akkuyu Nuclear Power Plant Project, Ankara: Akkuyu Nükleer A.Ş.
  • [3] U.S. Nuclear Regulatory Commission (1990), U.S. Nuclear Regulatory Commission Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants, NUREG- 1150, U.S.A. Washington: U.S. Nuclear Regulatory Commission.
  • [4] JONES J A ET AL, National Radiological Protection Board, Didcot, Oxon. (GB);HASEMANN I ET AL, Forschungszentrum Karlsruhe GmbH, Institut für Neutronenphysik und Reaktortechnik (DE) (1996), PC COSYMA (Code System from MARIA): An Accident Consequence Assessment Package for Use on a PC, EUR: European Commission's European MARIA project.

VVER–1200 SANTRALİNDE UZUN SÜRELİ SANTRAL KARARMASI NEDENİYLE KULLANILMIŞ YAKIT HAVUZU KAZASININ RADYOLOJİK SONUÇLARI

Yıl 2018, Cilt: 30 Sayı: 1, 1 - 6, 26.06.2018

Öz

Mart 2011’de Japonya Fukushima Daiichi Nükleer Güç
Santralinde (NGS) gerçekleşen doğal felaket nükleer çevrelere o güne değin
tasarıma esas kaza olarak kabul edilmeyen uzun süreli santral kararmasının
doğal afetler ile birleşince ne denli tehlikeli olabileceğini gösterdi. Bu tez
çalışmasında Mersin, Akkuyu’da kurulması planlanan AES 2006 tasarımı bir
VVER–1200 tipi NGS’de gerçekleşebilecek uzun süreli santral kararması kazası
durumunda kullanılmış yakıt havuzundaki envanter hesabı, envanterden kaynak
teriminin hesabı, kaynak terimin atmosferik dağılım hesapları ve sonucunda NGS
sahası yakınlarında bulunan kişilerin alması muhtemel radyasyon dozları ve acil
durum müdahaleleri incelenmiştir. 




Kaynakça

  • [1] Oak Ridge National Laboratory (2002), ORIGEN-ARP: Isotope Generation and Depletion Code, Oak Ridge, Tennessee: Oak Ridge National Laboratory.
  • [2] Akkuyu Nükleer A.Ş. (2014), Environmental Impact Assessment Report of Akkuyu Nuclear Power Plant Project, Ankara: Akkuyu Nükleer A.Ş.
  • [3] U.S. Nuclear Regulatory Commission (1990), U.S. Nuclear Regulatory Commission Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants, NUREG- 1150, U.S.A. Washington: U.S. Nuclear Regulatory Commission.
  • [4] JONES J A ET AL, National Radiological Protection Board, Didcot, Oxon. (GB);HASEMANN I ET AL, Forschungszentrum Karlsruhe GmbH, Institut für Neutronenphysik und Reaktortechnik (DE) (1996), PC COSYMA (Code System from MARIA): An Accident Consequence Assessment Package for Use on a PC, EUR: European Commission's European MARIA project.
Toplam 4 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Metroloji,Uygulamalı ve Endüstriyel Fizik
Bölüm Articles
Yazarlar

Kemal Doğan

Yayımlanma Tarihi 26 Haziran 2018
Yayımlandığı Sayı Yıl 2018 Cilt: 30 Sayı: 1

Kaynak Göster

APA Doğan, K. (2018). CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200. Turkish Journal of Nuclear Sciences, 30(1), 1-6.
AMA Doğan K. CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200. Turkish Journal of Nuclear Sciences. Haziran 2018;30(1):1-6.
Chicago Doğan, Kemal. “CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200”. Turkish Journal of Nuclear Sciences 30, sy. 1 (Haziran 2018): 1-6.
EndNote Doğan K (01 Haziran 2018) CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200. Turkish Journal of Nuclear Sciences 30 1 1–6.
IEEE K. Doğan, “CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200”, Turkish Journal of Nuclear Sciences, c. 30, sy. 1, ss. 1–6, 2018.
ISNAD Doğan, Kemal. “CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200”. Turkish Journal of Nuclear Sciences 30/1 (Haziran 2018), 1-6.
JAMA Doğan K. CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200. Turkish Journal of Nuclear Sciences. 2018;30:1–6.
MLA Doğan, Kemal. “CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200”. Turkish Journal of Nuclear Sciences, c. 30, sy. 1, 2018, ss. 1-6.
Vancouver Doğan K. CONSEQUENCES OF SPENT FUEL POOL ACCIDENT DUE TO LONG TERM BLACK OUT AT VVER-1200. Turkish Journal of Nuclear Sciences. 2018;30(1):1-6.