Araştırma Makalesi

Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks

Cilt: 2 Sayı: 1(3) 1 Haziran 2017
  • Özkan Küçük
  • Burak Öztürk
  • Samed Varhan
PDF İndir
EN

Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks

Abstract

Introduction. The finite element method is often used to shape the design geometries of pipes and fittings. Analysis studies made with different types of fasteners have been investigated in the literature. It has been observed that the studies related to the pliable pipe connections commonly used in in-building installations are lacking. No study has been conducted on the flow analysis of the fasteners used in the transition from metal pipes to plastic pipes. Material and methods. The 32 series set necklace provides fluid flow between the metal pipe and the plastic pipe. The assembly model has been designed using the Solid Works program. Surface stresses due to cavitations are calculated in the fluid analysis Flow Simulation module. These values were chosen as the pressure acting on the static analysis module. Results. In the water network system, the transition from metal pipe to plastic pipe has been investigated. Internal pressure changes and cavitations were calculated. The effect of this fluid's pressure changes on the surfaces of the assembly design parts has been investigated. Conclusions. Quantities and safety coefficients of plastic pipe, metal pipe, connecting bolt, rear cap and frontal mask were calculated. In the literature, the internal pressure changes which are not included in the static analysis are calculated by this study and the effect on the results is examined.

Keywords

Kaynakça

  1. Özkan Küçük1, Burak Öztürk2*, Samed Varhan3 1 Kastamonu University, Faculty of Engineering and Architecture, Department of Materials Science and Nanotechnology Engineering, Kastamonu 2 Kastamonu University, Institute of Science, Materials Scienceand Engineering, Kastamonu 3 Yıldırım Beyazıt Üniversitesi, Faculty of Engineering and Natural Sciences, Department of Mechanical Engineering

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yazarlar

Özkan Küçük Bu kişi benim

Burak Öztürk Bu kişi benim

Samed Varhan Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2017

Gönderilme Tarihi

12 Temmuz 2017

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2017 Cilt: 2 Sayı: 1(3)

Kaynak Göster

APA
Küçük, Ö., Öztürk, B., & Varhan, S. (2017). Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks. The Turkish Journal Of Occupational / Environmental Medicine and Safety, 2(1(3), 73-79. https://izlik.org/JA45ZH47TN
AMA
1.Küçük Ö, Öztürk B, Varhan S. Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks. turjoem. 2017;2(1(3):73-79. https://izlik.org/JA45ZH47TN
Chicago
Küçük, Özkan, Burak Öztürk, ve Samed Varhan. 2017. “Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks”. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2 (1(3): 73-79. https://izlik.org/JA45ZH47TN.
EndNote
Küçük Ö, Öztürk B, Varhan S (01 Haziran 2017) Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2 1(3) 73–79.
IEEE
[1]Ö. Küçük, B. Öztürk, ve S. Varhan, “Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks”, turjoem, c. 2, sy 1(3), ss. 73–79, Haz. 2017, [çevrimiçi]. Erişim adresi: https://izlik.org/JA45ZH47TN
ISNAD
Küçük, Özkan - Öztürk, Burak - Varhan, Samed. “Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks”. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2/1(3) (01 Haziran 2017): 73-79. https://izlik.org/JA45ZH47TN.
JAMA
1.Küçük Ö, Öztürk B, Varhan S. Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks. turjoem. 2017;2:73–79.
MLA
Küçük, Özkan, vd. “Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks”. The Turkish Journal Of Occupational / Environmental Medicine and Safety, c. 2, sy 1(3), Haziran 2017, ss. 73-79, https://izlik.org/JA45ZH47TN.
Vancouver
1.Özkan Küçük, Burak Öztürk, Samed Varhan. Safety Calculation According to Fluid Analysis In Plastic-Metal Pipe Connection Passage Used In Water Supply Networks. turjoem [Internet]. 01 Haziran 2017;2(1(3):73-9. Erişim adresi: https://izlik.org/JA45ZH47TN